Quantum 3214 Скачать руководство пользователя страница 19

19 

 

Step 29: Setting Door Opening Travel

 

 
Do not use adjustments to compensate for a poorly 
balanced door. This will interfere with the proper 
operation of the travel adjustments and may damage 
door. 
 

The door opener is assembled with the open travel 
adjustment preset for a typical door, but all doors should be 
adjusted to stop as close as possible to the door’s “natural” 
fully open, resting position. 
 
To determine the door’s “natural” fully open, resting position, disconnect door from opener using the Emergency Release 
Disconnect (see page 26,

 

HOW TO OPERATE YOUR DOOR MANUALLY) and manually raise door to its “natural” fully 

open, resting position. Use this location for your open limit setting. To determine if door needs adjustment, activate the 
opener to bring door to fully open position. 
 

NOTE:

 If door does not open fully and opener light flashes (

make sure the bulb is installed and operating) 

check 

for an obstruction or see Adjustment #1, page 22 (Adjusting Opening Force). 
 

To adjust for a non-standard door or to precisely set the open position: Using the wall station, operate the door and stop it 
in mid-travel position; using a flathead screwdriver turn the OPEN travel adjuster for more (counter-clockwise) or less 
(clockwise) travel. A 1/4 turn equals approximately 1” of trolley movement. 
 

NOTE:

 Confirm that the door has stopped in the UP position as a result 

of the Upper Limit Switch and not because the Trolley has hit the open 
Stop Bolt, which is mounted in the Rail near the power head. The 
correct condition can be verified by observing that the openers 
Convenience Light does not flash after the fully open door comes to a 
stop. The faulty condition may also be confirmed visually by checking 
to see if the Trolley is resting against the stop bolt. 
 

To confirm final OPEN travel adjustment, activate the opener to bring door to 
fully open position. The opener light should 

not

 be flashing. 

 

Step 30: Infrared Safety Sensor Obstruction Test

 

 
Test Procedure

 

 
Starting with the door in the fully open 
position, place a 6” x 12” object on the floor 
progressively one foot from the left side of 
the door; center of door and one foot from 
the right side of door (as illustrated). In each 
position, activation of the opener with the 
wall station should cause the door to move 
approximately one foot, stop and then 
reverse to fully open position. The same 6” x 
12” object when placed on the floor should 
also cause a closing door to reverse. 
 
If the door does not respond properly to these tests, the Infrared Safety Sensors must be adjusted (refer to step 22 or 23 
depending on type of sensors used). Repeat this test procedure. If the door opener still will not respond properly and fails 
this test, the door may cause severe injury or death. Have a qualified service person make repairs. 

Содержание 3214

Страница 1: ...ease Disconnect 26 Wall Station Code Change Maintenance Schedule 27 and Programming 14 Trouble Shooting 28 Infrared Safety Sensors Alignment 16 Parts Breakdown Rail Assembly 29 Transmitter Code Change...

Страница 2: ...nstalling or servicing a garage door sys tem Use a sturdy non metallic step ladder AFTER INSTALLATION IS COMPLETE FASTEN THIS MANUAL NEAR GARAGE DOOR PERFORM PERIODIC SAFETY CHECKS MAINTENANCE AND ADJ...

Страница 3: ...E D INSTALLATION APPOSEZ L TIQUETTE RELATIVE AU D SACCOUPLEMENT D URGENCE SUR LE DISPOSITIF OU PROXIMITE DE CE DER NIER NE BRANCHEZ PAS L OUVRE PORTE AVANT D Y TRE AUTORIS PAR LA NOTICE UNE FOIS L OUV...

Страница 4: ...rared reversing sensors detect an obstruction in door path and react by reversing door 9 Multi Function Wall Station Wired wall station pro vides up down door motion control and independent overhead l...

Страница 5: ...nsure that the door is balanced and working properly A door that binds sticks or is out of balance could cause severe injury Do not attempt to compensate for an improperly adjusted door by the install...

Страница 6: ...vices on the garage door by securing lock latch to inside face of door with suitable screw Install only on a properly balanced garage door An improperly balanced door could cause severe in jury Have a...

Страница 7: ...motor end if ladder is not high enough Open the door and place a 2 x 4 piece of wood along the top sec tion of the garage door Rest the double rails on the 2 x 4 as illus trated Support the top secti...

Страница 8: ...n cover to Motor Power Head Unit and push straight on until cover locks into place Note light turns on automatically when door is activated and a 4 minute time delay circuit automatically turns light...

Страница 9: ...n Step 10 Install Entrapment Warning Label Install Entrapment Warning Label next to wall station in a prominent location Install Entrapment Warning Label next to Wall Station as illustrated If label a...

Страница 10: ...1 2 screws supplied make sure that the curved hooks protruding from the bracket are positioned over and in firm contact with the door track Note This opener is equipped with state of the art wire less...

Страница 11: ...entrapment protection It is very important that both wall brackets be mounted at the same height for proper alignment The brackets may be temporarily mounted to the jamb with a 1 flat head nail provi...

Страница 12: ...n of the door and do not staple through wire Be sure to leave about 12 of excess wire at each end so you will have enough slack wire to mount units Note If wires must be lengthened or spliced into pre...

Страница 13: ...elf check of the controls Check your local electrical codes If your local code requires permanent wiring use the specifications called for and in structions illustrated Permanent Wiring Procedure 1 En...

Страница 14: ...tation to Power Head Unit Note Do not press any button on the wall station until instructed 1 Press the PROGRAM Switch button located on the garage door power head unit once The red PROGRAM STATUS lig...

Страница 15: ...B or C on the first door transponder and set the second door trans ponder jumper to one of the other two positions A third door will use the remaining un used position Temporar ily remove the batteri...

Страница 16: ...brackets are mounted at the same height see Step 9 and remount if necessary Additional minor adjustments can be made by lightly bending the mounting brackets see Figure 2 Once the alignment light come...

Страница 17: ...the coin slot and twist coin to access battery compartment Some transmitters use two CR2016 or equivalent batteries while others use a single MN21 or equivalent battery Snap case together after replac...

Страница 18: ...or should stop on the floor with the cushion arm and the bottom door seal slightly compressed If the door reverses off the floor turn close travel knob 1 4 turn less If door is not completely closed t...

Страница 19: ...NOTE Confirm that the door has stopped in the UP position as a result of the Upper Limit Switch and not because the Trolley has hit the open Stop Bolt which is mounted in the Rail near the power head...

Страница 20: ...steps using a different five digit PIN for each additional opener Step 32 Installing Wireless Keyless Entry If Included Install all wall controls out of the reach of children and in a location where...

Страница 21: ...c The STATUS LED and the overhead lamp will flash on and off at a slow rate 4 Operate the door to the fully closed position 5 Turn the FORCE ADJ clockwise until the STATUS LED flickers or just turns o...

Страница 22: ...act with a 1 high solid test object laid flat on garage floor and stops instead of reversing reset the door close limits according to instruction in Step 28 adjusting until door reverses upon contact...

Страница 23: ...euillez lire attentivement les r gles de s curit page 3 et les instructions suivanres Faire fonc tionner uniquement lorsque l ouvre porte est correctement r gl et que la port est visible et sans obsta...

Страница 24: ...sing and causes the light to flash 7 If door stops travel for 1 second at midpoint during close and then continues to close it indicates that the batteries in the Wireless Infrared Safety Sensors are...

Страница 25: ...veral functions a It can be used to set a custom pet position see below b It can be used to set the opener s closing force See Adjustment 1 Page 21 To set a custom pet position start with the door in...

Страница 26: ...h rapidly approx 20 sec Release both buttons Do not perform this step to train additional hand held transmitters Note This operation erases all previously trained transmitters Additional transmitters...

Страница 27: ...rm safety reverse tests Step 28 and 30 Make any necessary adjustments Twice a Year Check chain tension If chain rests on bottom of rail adjust tension by turning the two chain adjusting nuts at the en...

Страница 28: ...urns to fully open position and opener light flashes Door arm adjustment Close travel adjustment is set beyond normal door position Obstructions on floor Adjust rod in tube to provide 1 of cushion com...

Страница 29: ...29 Parts Breakdown Rail Assembly All Models...

Страница 30: ...Sensor Mounting Bracket 2 6 306486 Wiring Harness 1 20 250597 Wired Receiving Unit 1 7 269025 Light Socket 1 20a 260598 Wireless Transponder Unit 1 8 260552 Lens 1 21 260600 Wired Sending Unit 1 9 25...

Страница 31: ...Can be programmed to hundreds of doors Flip lid covers key pads when not in use Multi Function Wall Control Station Part 297137 Allow independent door up down con trol and overhead light on off contro...

Страница 32: ...ct returned to the Manufacturer at Buyer s expense for inspection If judged by Manufacturer to be defective in material or workmanship the product will be replaced or repaired at the option of the Man...

Отзывы: