background image

Q6 Series

27

Storage

Your power chair should be stored in a dry place, free from temperature extremes. When storing, disconnect the
batteries from the power chair. See VI. “Batteries and Charging.” 

WARNING! If you fail to store the unit properly, the frame can rust and the electronics can be

damaged. Any corroded electronic connection should be replaced.

Batteries that are regularly and deeply discharged, infrequently charged, stored in extreme temperatures, or stored
without a full charge may be permanently damaged, causing unreliable performance and limited service life. It is
recommended that you charge the batteries periodically throughout periods of prolonged storage to ensure proper
performance.

You may wish to place several boards under the frame of your power chair to raise it off of the ground during
periods of prolonged storage. This takes the weight off the tires and reduces the possibility of flat spots developing
on the areas of the tires contacting the ground.

Disposal of Your Power Chair

Your power chair must be disposed of according to applicable local and national statutory regulations. Contact
your local waste disposal agency or Quantum Rehab Provider for information on proper disposal of power chair
packaging, metal frame components, plastic components, electronics, batteries, neoprene, silicone, and
polyurethane materials.

Cleaning and Disinfection

Use a damp cloth and mild, non-abrasive cleanser to clean the plastic and metal parts of your power chair.
Avoid using products that may scratch the surface of your power chair.

If necessary, clean your product with an approved disinfectant. Make sure the disinfectant is safe for use on
your product before application.

WARNING! Follow all safety instructions for the proper use of the disinfectant and/or cleaning

agent before applying it to your product. Failure to comply may result in skin irritation or

premature deterioration of upholstery and/or power chair finishes.

WARNING! Never hose off your power chair or place it in direct contact with water. Your power

chair has a painted, ABS plastic body shroud that allows it to be easily wiped clean with a damp

cloth.

WARNING! Never use any chemicals to clean a vinyl seat, as they may cause the seat to become

slippery or dry out and crack. Use soapy water and dry the seat thoroughly.

Wheel Replacement

If you have pneumatic tires and you have a flat tire, you can replace the tube. If your chair is equipped with a solid
tire insert, then you must replace the entire wheel assembly. Replacement tires, tubes, and wheel assemblies are
readily available through your Quantum Rehab Provider. 

WARNING! The wheels on your power chair should only be serviced or replaced by a Quantum

Rehab Provider or a qualified technician.

WARNING! Be sure that the controller’s power is turned off and the power chair is not in

freewheel mode before performing this procedure.

WARNING! When changing a tire, remove only the five lug nuts, then remove the wheel. If any

further disassembly is required, deflate the tire completely or it may explode.

V I I .   C A R E   A N D   M A I N T E N A N C E

Содержание Q6 Edge HD

Страница 1: ......

Страница 2: ... a prohibited action can cause personal injury and or equipment damage On the product this icon is represented as a black symbol with a red circle and red slash INTENDED USE The intended use of the Pride Mobility Products device is to provide mobility to persons limited to a seated position that have the capability of operating a powered wheelchair Quick Reference Information S A F E T Y G U I D E...

Страница 3: ...ize that not all English speaking countries use the same words or spellings please refer to the following chart for some common word variations that may be encountered throughout this manual Table 1 Word Variations USA Variation USA Variation USA Variation asphalt tarmac backward s rearward s center centre color colour cord lead curb kerb elevator lift meter metre provider dealer agent sidewalk pa...

Страница 4: ...on in this manual which you do not understand or if you require additional assistance for setup or operation please contact your Quantum Rehab Provider Failure to follow the instructions in this manual and those located on your power chair can lead to personal injury and or damage to the power chair including voiding the warranty PURCHASER S AGREEMENT By accepting delivery of this product you prom...

Страница 5: ...ngs and safety information found in the Consumer Safety Guide and refer to this resource often Unlocked and in freewheel mode Locked and in drive mode Place unit on level ground and stand to one side when changing from drive mode to freewheel mode or freewheel mode to drive mode Indicates power chair securement points Indicates that power chair with a similar label is not rated for occupied transi...

Страница 6: ... in assisting a power chair user in various daily living activities As you begin using your power chair during daily activities you will probably encounter situations in which you will need some practice Simply take your time and you will soon be in full and confident control as you maneuver through doorways on and off of elevators up and down ramps and over moderate terrain Below are some precaut...

Страница 7: ...Typically the seat assembly includes the armrests seatback and seat base The power base assembly includes two motor brake assemblies two drive wheels four caster wheels two batteries and wiring harnesses See figures 1 2 and 3 Figure 1 The Q6 Series Power Chair SEATBACK CASTER WHEEL JOYSTICK FRONT RIGGING FOOT PLATFORM SHOWN SEAT BASE CONTROLLER CASTER WHEEL ARMREST ARMREST POWER BASE ASSEMBLY SEAT...

Страница 8: ...re wiring harnesses See figure 2 Controller Harness Connector The controller harness connector is where the controller plugs into the power base Each controller uses a different type of harness Regardless of which type of controller is used the harness must be secured to the seat assembly and not allowed to drag on the floor Motor Connectors This is where the controller connects to the motors Batt...

Страница 9: ...eries and the motors are heavily strained e g from excessive loads the main circuit breaker trips to prevent damage to the motors and the electronics If the circuit trips allow your power chair to rest for approximately one minute The circuit breaker will reset itself Turn on the controller and continue normal operation If the main circuit breaker continues to trip repeatedly contact your Quantum ...

Страница 10: ...Pull up both manual freewheel levers for drive mode drive motor engaged See figure 5 NOTE You must turn off the power before disengaging the drive motors otherwise you may get an error code on the controller To clear this code turn off the controller and place the power chair in drive mode Then turn on the controller The error message should be cleared If it is not contact your Quantum Rehab Provi...

Страница 11: ...fort adjustments NOTE Any nylon insert lock nut removed during the disassembly or adjustment of the power chair must be replaced with a new nut Nylon insert lock nuts should not be reused as it may cause damage to the nylon insert resulting in a less secure fit Replacement nylon insert lock nuts are available at local hardware stores or through your Quantum Rehab Provider I V A S S E M B L Y Figur...

Страница 12: ...y lose control of the seat if they do so To install the seat 1 Tilt the seat back and slide the rear extrusion onto the rear trapeze bar See figure 7 2 Lower the front extrusion onto the front trapeze bar until the seat locks into place 3 Flip the seat latch safety down WARNING Make sure the seat latch safety is flipped down before using your power chair 4 Install the controller and route the harn...

Страница 13: ...wn point is clearly labeled for this purpose To secure a power chair equipped with tie down points Always secure the power chair in a forward facing position in the vehicle Attach the four tie down straps only to designated labeled transit securement points indicated by anchor symbols on the power chair See figure 10 Tighten the straps to sufficiently remove all the slack Never attach tie downs to...

Страница 14: ...14 Q6 Series I V A S S E M B L Y Figure 11 Unoccupied Transit System Securement Points FRONT OF VEHICLE ...

Страница 15: ...RT ADJUSTMENTS After becoming familiar with your power chair s operation you may find the need to make some adjustments to increase your comfort such as seat height and angle armrest width armrest angle and height foot platform height depth and angle and controller position NOTE If your power chair is equipped with a Specialty Seat Synergy Seat or TRU Balance Power Position ing System refer to the...

Страница 16: ...the power chair is in drive mode 3 Unplug the controller connector s from the power base 4 Remove the seat from the power base 5 Remove both extrusions from the bottom of the seat 6 Reposition the extrusions on a different set of mounting holes You must move both extrusions the same number of holes either forward or back wards See figure 13 7 Fasten the extrusions back onto the bottom of the seat ...

Страница 17: ...nobs on each side of the armrest receiver bracket See figure 14 2 Loosen the knobs 3 Slide the armrests in or out to the desired width 4 Tighten the knobs Armrest Angle Adjustment To change the armrest angle 1 Lift the armrest straight up so that it is perpendicu lar to the floor See figure 14 2 Loosen the jam nut 3 Turn the adjusting screw to raise or lower the front of the armrest 4 Tighten the ...

Страница 18: ...ler position 1 Turn off the power to the controller 2 Unplug the controller connector s from the power base 3 Remove any wire ties securing the controller har ness to the armrest 4 Flip up the armrest so it is perpendicular to the floor 5 Loosen the setscrew on the controller bracket 6 Slide the controller out of the armrest 7 Loosen the setscrew in the other armrest 8 Place the controller in the ...

Страница 19: ...rm bracket and tighten Foot Platform Depth Adjustment You can adjust the depth of the foot platform To adjust the foot platform depth 1 Remove the hardware from the foot platform bracket See figure 16 2 Move the foot platform in or out to the desired depth 3 Reinstall the hardware into the foot platform bracket and tighten Foot Platform Angle Adjustment You can adjust the angle of the foot platfor...

Страница 20: ...ipped with a positioning belt that can be adjusted for operator comfort See fig ure 17 The positioning belt is designed to support the operator so that he she does not slide down or forward in the seat The positioning belt is not designed for use as a restraining device WARNING The positioning belt is not designed for use as a seat belt in a motor vehicle Nor is your power chair suitable for use a...

Страница 21: ... properly wired standard electrical outlet PROHIBITED Do not allow unsupervised children to play near the power chair while the batteries are charging Pride recommends that you do not charge the batteries while the power chair is occupied MANDATORY Read the battery charging instructions in this manual and in the manual supplied with the battery charger before charging the batteries WARNING Explosi...

Страница 22: ...use a different battery charger You should use the charger supplied with the power chair It is the safest most efficient tool to charge the batteries We do not recommend using other types of chargers e g an automotive battery charger NOTE Your power chair s charger will not operate after the batteries have been discharged to nearly zero voltage If this happens call your Quantum Rehab Provider for ...

Страница 23: ...mprove battery performance and battery life What type of batteries should I use We recommend deep cycle batteries that are sealed and maintenance free Both AGM and Gel Cell are deep cycle batteries that are similar in performance Refer to the specifications table for more information regarding the batteries used with your power chair WARNING Corrosive chemicals contained in batteries Use only AGM ...

Страница 24: ... for an extended period fully charge the batteries prior to storage Disconnect the battery harnesses and store the power chair in a warm dry environment Avoid temperature extremes such as freezing and excessively hot conditions and never attempt to charge a frozen battery A cold or frozen battery should be warmed for several days prior to recharging What about public transportation AGM and Gel Cel...

Страница 25: ...ould be inspected often for corrosion and electronic components may need to be replaced frequently Temperature Some of the parts of your power chair are susceptible to extreme changes in temperature Always keep your power chair between the temperatures of 18 F 8 C and 122 F 50 C In extremely cold temperatures the batteries may freeze The specific temperature at which they freeze depends on a numbe...

Страница 26: ...er chair Do not overtighten any screws Check for proper tire inflation Pneumatic tires should be inflated to the psi bar kPa air pressure rating indi cated on each tire If a tire does not hold air see your Quantum Rehab Provider for replacement of the tube Check the brakes This test should be carried out on a level surface with at least 3 feet 1 meter of clearance around your power chair To check ...

Страница 27: ...ic and metal parts of your power chair Avoid using products that may scratch the surface of your power chair If necessary clean your product with an approved disinfectant Make sure the disinfectant is safe for use on your product before application WARNING Follow all safety instructions for the proper use of the disinfectant and or cleaning agent before applying it to your product Failure to compl...

Страница 28: ...ry Replacement A battery wiring diagram is printed on a decal located on the front cover See the specification table for correct battery specifications MANDATORY Battery posts terminals and related accessories contain lead and lead compounds Wear goggles and gloves when handling batteries and wash hands after handling WARNING The batteries in your power chair should only be serviced or replaced by...

Страница 29: ...er base 4 Disconnect the quick release battery connectors See figure 3 5 Remove the batteries 6 Disconnect the battery harness from each battery 7 Connect the battery harness to the new front battery according to the battery wiring diagram See figure 21 WARNING Make sure you tighten the fasteners so that the connections are secure 8 Connect the battery harness to the new rear battery according to ...

Страница 30: ...wer up Powers up but does not move Loose seat or seating components Corrective Maintenance If the battery condition meter does not light up when you turn on the power Check the harness connections Make sure they are tight Check the circuit breaker Reset it if necessary Check the battery connections If the above conditions prove normal you can load test the batteries with a battery load tester Thes...

Отзывы: