6-157
PUTR
PUT Relative
Classification:
Direct processor control
Command Syntax:
PUTR <value>
Limits:
<value> = 0 to 2^(SIZE)-1
Query Syntax:
None
Description:
The PUTR command writes the specified value <value> into
the location pointed to by the address register (see the ADDR
command). The parameter <value> is interpreted according to
the current setting of BASE (see the BASE command). The number
and format of the bits written depend on the current setting of
S I Z E ( s e e t h e S I Z E c o m m a n d ) . T h e a d d r e s s r e g i s t e r i s
automatically incremented by SIZE bits after the current location
has been written to.
Note – This command will normally be used only with custom
applications and command files created by Quantum Data.
Indiscriminate use of this command can cause the generator to
stop operating and / or the loss of stored data in nonvolatile
RAM.
Other Required Cmds:
PUTR expects parameters formatted according to the current
radix set by the BASE command.
Example:
U s e o n l y w i t h c o d e s u p p l i e d b y Q u a n t u m
D a t a !
RATC
pixel RATe Calibration factor
Classification:
System parameter setting
Command Syntax:
RATC <factor>
Limits:
<factor> = Floating point number equal to calibration factor
Typical min. = 0.99990
Typical max = 1.00010
Query Syntax:
RATC?
Query Response:
<factor>
Description:
The RATC command sets an internal multiplication factor used
in setting the pixel clock frequency. The multiplication factor
can be set to compensate for the frequency error of the internal
reference crystal. Having to use a factor outside of the typical
range may indicate a failure of generator’s hardware. Re-
initializing the generator’s memory sets the calibration factor
to a factory-default setting of 1.00000.
Note – The RATC parameter is a system level parameter that
will affect the pixel clock frequency of all Formats that are
recalled. The RATC value will be retained when the generator
is powered down and back up again. Query the current setting
of RATC if you are experiencing problems with the pixel clock
or scan rate being off in frequency.
Other Required Cmds:
None
Example:
R A T C 1 . 0 0 0 0 7 / / I n c r e a s e s p i x c l k b y
/ / f a c t o r o f 1 . 0 0 0 0 7
Содержание 801GC, 801GF, 801GX
Страница 1: ...Owner s and Programmer s Manual Model 801GC 801GF 801GX Portable Video Signal Generators ...
Страница 16: ...xiv Table of Contents Models 801GC 801GF 801GX Rev A Notes ...
Страница 17: ...1 1 Features Product Overview Chapter 1 Introduction ...
Страница 21: ...2 1 Operating Modes Displays Indicators Knobs Switches Buttons Chapter 2 Basic Operation ...
Страница 31: ...3 1 Introduction Format charts Chapter 3 Built In Formats ...
Страница 39: ...4 1 Description of the test images and how to use them Chapter 4 Built In Images ...
Страница 126: ...5 14 Chapter 5 Making Connections Model 801GC 801GF 801GX Rev A Notes ...
Страница 304: ...6 178 Chapter 6 Programming Model 801GC 801GF 801GX Rev A Notes ...
Страница 305: ...7 1 Power on Computer Interfacing If all else fails Chapter 7 Troubleshooting ...
Страница 309: ...8 1 System Errors Format Errors System Error Message Summary Format Error Message Summary Chapter 8 Error Messages ...
Страница 335: ...9 1 Chapter 9 Service New Product Warranty Product Updates Service Agreements Authorized Service Centers ...
Страница 346: ...A 6 Appendix A Specifications Model 801GC 801GF 801GX Rev A Notes ...