background image

S

AFETY

 I

NFORMATION

E

LECTROSTATIC

 D

ISCHARGE

 (ESD)

 

3-6

Particular attention should be given to supply connections other 

than direct connections to the branch circuit (e.g. use of power 

strips).

Electrostatic Discharge (ESD)

Always handle boards carefully. They can be extremely sensi-

tive to ESD. Hold boards only by their edges. After removing a 

board from its protective wrapper or from the server, place the 

board component side up on a grounded, static free surface. 

Use a conductive foam pad if available but not the board wrap-

per. Do not slide board over any surface.

Other Hazards

Battery Replacement

Cooling and Airflow

CAUTION!

ESD 

CAN

 

DAMAGE

 

DRIVES

BOARDS

AND

 

OTHER

 

PARTS

. W

E

 

RECOM

-

MEND

 

THAT

 

YOU

 

PERFORM

 

ALL

 

PROCEDURES

 

AT

 

AN

 ESD 

WORKSTA

-

TION

. I

F

 

ONE

 

IS

 

NOT

 

AVAILABLE

PROVIDE

 

SOME

 ESD 

PROTECTION

 

BY

 

WEARING

 

AN

 

ANTISTATIC

 

WRIST

 

STRAP

 

ATTACHED

 

TO

 

CHASSIS

 

GROUND

 -- 

ANY

 

UNPAINTED

 

METAL

 

SURFACE

 -- 

ON

 

YOUR

 

SERVER

 

WHEN

 

HANDLING

 

PARTS

.

CAUTION!

T

HERE

 

IS

 

THE

 

DANGER

 

OF

 

EXPLOSION

 

IF

 

THE

 

BATTERY

 

IS

 

INCOR

-

RECTLY

 

REPLACED

. W

HEN

 

REPLACING

 

THE

 

BATTERY

USE

 

ONLY

 

THE

 

BATTERY

 

RECOMMENDED

 

BY

 

THE

 

EQUIPMENT

 

MANUFACTURER

.

!

!

CAUTION!

D

ISPOSE

 

OF

 

BATTERIES

 

ACCORDING

 

TO

 

LOCAL

 

ORDINANCES

 

AND

 

REG

-

ULATIONS

.

CAUTION!

D

O

 

NOT

 

ATTEMPT

 

TO

 

RECHARGE

 

A

 

BATTERY

.

CAUTION!

D

O

 

NOT

 

ATTEMPT

 

TO

 

DISASSEMBLE

PUNCTURE

OR

 

OTHERWISE

 

DAM

-

AGE

 

A

 

BATTERY

.

CAUTION!

C

AREFULLY

 

ROUTE

 

CABLES

 

AS

 

DIRECTED

 

TO

 

MINIMIZE

 

AIRFLOW

 

BLOCKAGE

 

AND

 

COOLING

 

PROBLEMS

. F

OR

 

PROPER

 

COOLING

 

AND

 

AIR

-

FLOW

OPERATE

 

THE

 

SYSTEM

 

ONLY

 

WITH

 

THE

 

CHASSIS

 

COVERS

 

INSTALLED

. O

PERATING

 

THE

 

SYSTEM

 

WITHOUT

 

THE

 

COVERS

 

IN

 

PLACE

 

CAN

 

DAMAGE

 

SYSTEM

 

PARTS

. T

O

 

INSTALL

 

THE

 

COVERS

:

Check first to make sure you have not left loose tools or parts 

inside the system.

Check that cables, add-in cards, and other components are 

properly installed.

Attach the covers to the chassis according to the product 

instructions.

!

!

!

!

Содержание Stratos S810-X52L

Страница 1: ...STRATOS S810 Series S810 X52L Ultra Dense High Computing Multi node 2U Server User s Guide Document Version 1 2 0...

Страница 2: ...ce denotes keyboard keys WARNING Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device CAUTION CAUTIONS APPEAR BEFORE THE...

Страница 3: ...PC AT compatible region of battery backed 128 bytes of mem ory which normally resides on the baseboard CPU Central Processing Unit Deasserted A signal is deasserted when in the inactive state Active...

Страница 4: ...rity Ms Milliseconds Mux Multiplexer NIC Network Interface Card NMI Nonmaskable Interrupt NM Node Management OBF Output buffer OEM Original Equipment Manufacturer Ohm Unit of electrical resistance PDB...

Страница 5: ...Server Management Interrupt SMI is the highest priority nonmaskable interrupt SMM Server Management Mode SMS Server Management Software SNMP Simple Network Management Protocol SOL Serial Over LAN UART...

Страница 6: ...ening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedur...

Страница 7: ...SAFETY INFORMATION XXI...

Страница 8: ...sclaimer The information in this document is subject to change without notice The manufacturer makes no representations or warran ties with respect to the contents hereof and specifically dis claims a...

Страница 9: ...About the Server Chapter 1...

Страница 10: ...m Features The system comprises a 2U 30 5 long chassis using a stan dard SSI mainboard Some of the major features are as follows Chipset Intel C600 series upgradable ROM kit support Processors x2 Inte...

Страница 11: ...ntroller Quanta LSISAS 2008 Mezzanine card optional Quanta LSISAS 2108 Mezzanine card optional Intel SAS controller Intel C602 Patsburg A upgrade ROM 1 optional Intel C602 Patsburg A upgrade ROM 2 opt...

Страница 12: ...50 60 optional Network 2 Intel Powerville I350 GbE RJ45 ports on board per node 1 Quanta 10Gb SFP dual port mezzanine card optional 2 Intel Twinville X540 10G BASE T RJ45 ports on board per node 1 Qu...

Страница 13: ...cy redundant PSU 200 240VAC 50 60Hz optional TPM No RoHS Yes Intel Node Management support No System Management IPMI v2 0 Compliant on board KVM over IP support Table 1 1 S810 X52L SKU Continued S810...

Страница 14: ...node configuration 1 x 2U server chassis 2 x Mainboard modules 2 x Dummy modules 4 x Processor heatsinks 16 x Dummy DIMMs 1 x Power supply 1 x Power cord Utility CD Technical Guide included Rail kit...

Страница 15: ...nt Overview 1 2 3 4 5 6 7 8 9 Table 1 2 2 5 System Component Overview No Item Description 1 PSUs 2 Power supply units PSU 2 Chassis System chassis 3 Node controller Controls and LEDs for system manage...

Страница 16: ...iption No Item Description 1 PSUs 2 Power supply units PSU 2 Chassis System chassis 3 Node controller Controls and LEDs for system management 4 3 5 HDDs 12 3 5 hard disk drive HDD cage 5 Fans Fan modu...

Страница 17: ...uration Figure 1 4 2 5 HDD Configuration 3 5 HDD Group Configuration Figure 1 5 3 5 HDD Configuration Note 2 5 SKU shown Figure 1 3 Table 1 4 System Front Features No Feature Description 1 Node contro...

Страница 18: ...BAY MB2 HDD BAY MB3 HDD BAY MB4 HDD BAY 3 MB2 Power Button Power On Off for MB2 4 MB2 ID Button MB2 module ID LED control 5 MB3 Power Button Power on off for MB3 6 MB3 ID Button MB3 module ID LED cont...

Страница 19: ...on Green LED On DC on 3 MB2 Power Button LED Green LED Off DC off 5 MB3 Power Button LED Amber LED Blinking DC off and fault 7 MB4 Power Button LED Green LED Amber LED alternate blinking DC on and fau...

Страница 20: ...1 10 S810 X52L Module I O Features WARNING Mainboard combinations other than S810 X52L are not supported TOPPSU BOTTOMPSU MB 1 MB 2 MB 3 MB 4 Table 1 7 S810 X52L Module I O Features No Feature Descrip...

Страница 21: ...AN LEDs Right Off No link Green On Link no access Green Blinking Link access Left Off No link link access 10 Mbps Green On Link access 100 Mbps Amber On Link access 1000 Mbps 7 Remote Management port...

Страница 22: ...ing N A N A 1 GbE LED Amber Green Blinking Amber Green Blink ing 100M Off Green Blinking Green Green Blink ing Link Activity PIN 1 Location Table 1 10 HDD LED Description SGPIO LED Pattern Slot Device...

Страница 23: ...wing each PSU to individually provide power for all mainboards MB1 to MB4 The power supply units used for each model are PSU LED Figure 1 13 PSU LED WARNING Mainboard combinations other than S810 X52L...

Страница 24: ...in for some time after the system has been pow ered off Allow time for the fans to stop rotating before handling system components Figure 1 14 Cooling Sub System Table 1 13 Fan Cooling System No Featu...

Страница 25: ...Installation and Assembly Safety Instructions Chapter Installation and Assembly Safety Instructions Chapter...

Страница 26: ...AC power cord if it is not the exact type required A product with more than one power supply will have a separate AC power cord for each supply The power button on the system does not turn off system...

Страница 27: ...trostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 6 Do not operate the system with t...

Страница 28: ...surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power supply...

Страница 29: ...Safety Information Chapter Safety Information Chapter...

Страница 30: ...ll void the UL List ing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the product is sold Safety Warnings and Cautions...

Страница 31: ...into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power...

Страница 32: ...HE CHASSIS OR ADD OR REMOVE ANY NON HOT PLUG COMPONENTS CAUTION DO NOT ATTEMPT TO MODIFY OR USE AN AC POWER CORD IF IT IS NOT THE EXACT TYPE REQUIRED A SEPARATE AC CORD IS REQUIRED FOR EACH SYSTEM POW...

Страница 33: ...the system by pressing the power button to off Disconnect the AC power by unplugging all AC power cords from the system or wall outlet Disconnect all cables and telecommunication lines that are connec...

Страница 34: ...ere fore consideration should be given to installing the equipment in an environment compatible with the maximum ambient tem perature Tma specified by the manufacturer Reduced Air Flow Installation of...

Страница 35: ...G AN ANTISTATIC WRIST STRAP ATTACHED TO CHASSIS GROUND ANY UNPAINTED METAL SURFACE ON YOUR SERVER WHEN HANDLING PARTS CAUTION THERE IS THE DANGER OF EXPLOSION IF THE BATTERY IS INCOR RECTLY REPLACED W...

Страница 36: ...TO AVOID RISK OF RADIATION EXPOSURE AND OR PERSONAL INJURY Do not open the enclosure of any laser peripheral or device Laser peripherals or devices are not serviceable Return to manufacturer for servi...

Страница 37: ...Regulatory and Compliance Information Chapter Regulatory and Compliance Information Chapter...

Страница 38: ...Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interfer ence received including interferen...

Страница 39: ...on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the...

Страница 40: ...anging or use of other component will void the UL listing and other product certifications and approvals Updated product information for configurations can be found on the site at the following URL ww...

Страница 41: ...icable threshold limits or 2 an approved pending RoHS exemption applies RoHS implementation details are not fully defined and may change Threshold limits and banned substances are noted below Quantity...