BMC
C
ONFIGURATION
G
ROUP
3-44
Procedure:
1. In the
LAN Destination Tab
, choose the slot to be configured. This should be the
same slot that you have selected in the Alert Policy Entry?] Destination Selector
field. That is if you have chosen the Destination Selector as 4 in the Alert Policy Entry
page of Alert Policy Tab, then you have to configure the 4th slot of LAN Destination
Page.
2. Double click the slot and click
Modify
. This opens the
Add LAN Destination entry
.
Figure 3-30.
Add LAN Destination entry Page
3. In the
LAN Destination
field, the destination for the newly configured entry is dis-
played and this is a read only field.
4. In the
Destination Type
field, select the one of the types.
5. In the
Destination Address
field, enter the destination address.
6. Select the
User Name
from the list of users.
7. In the
Subject
field, enter the subject.
8. In the
Message
field, enter the message.
9. Click
Add
to save the new LAN destination and return to LAN destination list.
10. Click
Cancel
to cancel the modification and return to LAN destination list.
11. In the
LAN Destination Tab
, to modify a configuration, select the row to be modi-
fied and click
Modify
.
12. In the
LAN Destination Tab
, to delete a configuration, select the slot and click
Delete
.
Destination Address
If Destination type is SNMP Trap, then enter the IP address of the system
that will receive the alert. Destination address will support the follow-
ing:
IPv4 address format.
IPv6 address format.
Send Test Alert
These fields must be configured if email alert or SNMP Trap is chosen as
destination type. This field will send a test message in the message
field's content to specified destination.
Modify
To modify existing LAN destination list.
Delete
To delete LAN destination list.
Table 18: PEF Management - LAN Destination (Continued)
I
TEM
D
ESCRIPTION
Содержание QuantaGrid Series
Страница 1: ...Version 1 0 QuantaGrid Series D51PC 1U Versatile Compact 2 Socket Server User s Guide...
Страница 7: ...TABLE OF CONTENT VI Regulatory and Compliance Information...
Страница 51: ...BIOS CHECKPOINTS 2 21 b Error code POST Error MRC Fatal Warning Code One reset switch To trigger system reset...
Страница 52: ...BMC Chapter 3 This section provides information and key features of BMC Baseboard Management Controller...
Страница 128: ...This page left blank intentionally...