7.3 Read-Only Registers Table
7.3.1 Read-Only Variables
Address
Type
Description
0x8000
WORD
Firmware Release:
Bit15÷11
– Version number
Bit10÷6
– Revision number
Bit5÷0
– Build number
0x8001
INT
Temperature T1 (°C o °F)
0x8002
INT
Temperature T2 (°C o °F)
0x8003
INT
Temperature T3 (°C o °F)
0x8004
INT
Temperature T4 (°C o °F)
0x8005
BITMAP Bitmap #1 Alarms Status:
Bit0.
Default Configuration
Bit1.
Active FAN (T1)
Bit2.
Active FAN (T2)
Bit3.
Active FAN (T3)
Bit4.
Active FAN (T4)
Bit5.
ALARM (T1)
Bit6.
ALARM (T2)
Bit7.
ALARM (T3)
Bit8.
ALARM (T4)
Bit9.
TRIP (T1)
Bit10. TRIP (T2)
Bit11. TRIP (T3)
Bit12. TRIP (T4)
Bit13. Probe FAULT (T1)
Bit14. Probe FAULT (T2)
Bit15. Probe FAULT (T3)
0x8006
BITMAP Bitmap #2 Alarms Status:
Bit0.
Probe FAULT (T4)
Bit1.
FCD: Temperature Rapid Rise (T1)
Bit2.
FCD: Temperature Rapid Rise (T2)
Bit3.
FCD: Temperature Rapid Rise (T3)
Bit4.
FCD: Temperature Rapid Rise (T4)
Bit5.
Probe T1 OFF
Bit6.
Probe T2 OFF
Bit7.
Probe T3 OFF
Bit8.
Probe T4 OFF
Bit9.
Bit10.
Bit11.
Bit12.
Bit13.
Bit14.
Bit15
0x8007
DWORD Total Working Hours
0x8008