UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9
User’s Guide 315/1523
6.7.2.7
Set the password lock-out count
Use this command to strengthen the security of the switch by locking user accounts that have failed login
due to wrong passwords. When a lockout count is configured, a user that is logged in must enter the
correct password within that count. Otherwise the user will be locked out from further switch access.
Only a user with read/write access can re-activate a locked user account. The user can go to the CLI
Global Configuration Mode to set the password lock-out count, use the
passwords lock-out <1-5>
Global configuration command. Use the
no passwords lock-out
to return to default value 0.
Syntax
passwords lock-out <1-5>
no passwords lock-out
<1-5>
- the number of password failures before account lock.
Default Setting
0
Command Mode
Global Config
6.7.2.8
Set the minimum password length
The user can go to the CLI Global Configuration Mode to set the minimum password length, use the
passwords min-length <8-64>
Global configuration command. Use the
no passwords min-length
return to default value 8.
Syntax
passwords min-length <8-64>
no passwords min-length
Default Setting
8
Command Mode
Global Config