Quanta Computer Rackgo M Series Скачать руководство пользователя страница 9

 

P

RECAUTIONARY

 M

EASURES

 

VIII

Electrostatic Discharge (ESD)

Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only 
by their edges without any component and pin touching. After removing a board from its 
protective wrapper or from the system, place the board component side up on a 
grounded, static free surface. Use a conductive foam pad if available but not the board 
wrapper. Do not slide board over any surface.

Cooling and Airflow

Please be aware that slots and openings on the front and rear side of the chassis are 
designed for ventilation; to make sure reliable operation of your system and to protect it 
from overheating, these openings must not be covered or blocked. The openings should 
never be covered or blocked by placing the product on a bed, sofa, rug, or other similar 
surface. This product should never be placed near or over a radiator or heat register, or in a 
built-in installation unless proper ventilation is provided.

Laser Peripherals or Devices

Use certified and rated Laser Class I for Optical Transceiver product.

Heed safety instructions: 

Before working with the system, whether using this manual or 

any other resource as a reference, pay close attention to the safety instructions. Adhere to 
the assembly instructions in this manual to ensure and maintain compliance with existing 
product certifications and approvals. Use only the described, regulated components spec-

CAUTION!

ESD 

CAN

 

DAMAGE

 

DRIVES

BOARDS

AND

 

OTHER

 

PARTS

. W

E

 

RECOMMEND

 

THAT

 

YOU

 

PERFORM

 

ALL

 

PROCEDURES

 

AT

 

AN

 ESD 

WORKSTATION

. I

F

 

ONE

 

IS

 

NOT

 

AVAILABLE

PROVIDE

 

SOME

 ESD 

PROTECTION

 

BY

 

WEARING

 

AN

 

ANTI

-

STATIC

 

WRIST

 

STRAP

 

ATTACHED

 

TO

 

CHASSIS

 

GROUND

 -- 

ANY

 

UNPAINTED

 

METAL

 

SURFACE

 -- 

ON

 

YOUR

 

SERVER

 

WHEN

 

HANDLING

 

PARTS

.

CAUTION!

C

AREFULLY

 

ROUTE

 

CABLES

 

AS

 

DIRECTED

 

TO

 

MINIMIZE

 

AIRFLOW

 

BLOCKAGE

 

AND

 

COOLING

 

PROBLEMS

. F

OR

 

PROPER

 

COOLING

 

AND

 

AIRFLOW

OPERATE

 

THE

 

SYSTEM

 

ONLY

 

WITH

 

THE

 

CHASSIS

 

COVERS

* / 

AIR

 

DUCT

 

INSTALLED

O

PERATING

 

THE

 

SYSTEM

 

WITHOUT

 

THE

 

COVERS

 / 

AIR

 

DUCT

 

IN

 

PLACE

 

CAN

 

DAMAGE

 

SYSTEM

 

PARTS

 . T

O

 

INSTALL

 

THE

 

COVERS

* / 

AIR

 

DUCT

:

Check first to make sure you have not left loose tools or parts inside the system.

Check that cables, add-in cards, and other components are properly installed.

Attach the covers* / air duct to the chassis according to the product instructions. 

* May not apply to all systems.

CAUTION!

T

O

 

AVOID

 

RISK

 

OF

 

RADIATION

 

EXPOSURE

 

AND

 / 

OR

 

PERSONAL

 

INJURY

:

Do not open the enclosure of any laser peripheral or device.

Laser peripherals or devices are not serviceable.

Return to manufacturer for servicing.

!

!

!

Содержание Rackgo M Series

Страница 1: ...Version 1 0 Rackgo M Series MS100 High Density Half Width JBOD with up to 6TB Storage Capacity User s Guide...

Страница 2: ...on in this document is subject to change without notice The manufacturer makes no representations or warranties with respect to the contents hereof and specifi cally disclaims any implied warranties o...

Страница 3: ...TABLE OF CONTENT II TABLE OF CONTENT About the System Introduction 1 1 Main Features 1 1 Regulatory and Compliance Information...

Страница 4: ...pe face denotes keyboard keys Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device WARNING Warning information appears be...

Страница 5: ...viced only by technically qualified persons You must adhere to the guidelines in this guide and the assembly instructions in related chapters to ensure and maintain compliance with existing product ce...

Страница 6: ...rms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided wit...

Страница 7: ...ARATE THE SYS TEM FROM THE POWER SOURCE CAUTION TO AVOID RISK OF ELECTRIC SHOCK DISCONNECT ALL CABLING FROM THE SYSTEM AND REMOVE THE SYSTEM FROM THE RACK CAUTION TO AVOID PERSONAL INJURY OR PROPERTY...

Страница 8: ...nt If installed in a closed or multi unit rack assembly the oper ating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installin...

Страница 9: ...ther resource as a reference pay close attention to the safety instructions Adhere to the assembly instructions in this manual to ensure and maintain compliance with existing product certifications an...

Страница 10: ...carefully They can be extremely sensi tive to electrostatic discharge ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board componen...

Страница 11: ...recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with suff...

Страница 12: ...Chapter 1 About the System This section introduces the system its different configuration s and the main features Chapter 2 Regulatory and Compliance Information This section provides regulatory and...

Страница 13: ...About the System Chapter 1 This section introduces the system its different configuration s and the main features...

Страница 14: ...storage blade Each HDD board provides four HDD SAS connectors Environmental Requirements Table 1 Environmental Requirements SPECIFICATION CONDITION REQUIREMENTS Inlet Temperature Operating 77 F to 95...

Страница 15: ...TUS CONDITION Off Blade is not fully inserted 12V power is absent or Blade Enable is de asserted Solid Amber ON Blade is inserted 12V power is available Blade Enable is asserted but main 12Vpower is n...

Страница 16: ...Regulatory and Compliance Information Chapter 2 This section provides regulatory and compliance information applicable to this system...

Страница 17: ...is sold Safety Warnings and Cautions To avoid personal injury or property damage before you begin installing the product read observe and adhere to all of the following safety instructions and informa...

Страница 18: ...ional health and safety requirements when moving and lifting equipment Use mechanical assistance or other suitable assistance when moving and lifting equipment To reduce the weight for easier handling...

Страница 19: ...this product Turn off the system by pressing the power button to off Disconnect the AC power by unplugging all AC power cords from the system or wall outlet Disconnect all cables and telecommunication...

Страница 20: ...e connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment namepl...

Страница 21: ...the system plugs into shall be installed near the equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 T...

Страница 22: ...ventilated and away from sources of heat including direct sunlight Away from sources of vibration or physical shock Isolated from strong electromagnetic fields produced by electrical devices In region...

Страница 23: ...y with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat...

Страница 24: ...interference Install and use the equipment according to the instruction manual BSMI Taiwan The BSMI Certification Marking and EMC warning is located on the outside rear area of the product MSIP Korea...

Страница 25: ...eripheral Storage Devices must be UL recognized or UL listed accessory and TUV or VDE licensed Maximum power rating of any one device is 19 watts Total server configuration is not to exceed the maximu...