background image

Chapter 2 

 

34 

KEMX-6000 User’s Manual 

 

 

Table 26 COM6 RS-232 Port 6 Pin Header 

9

2

1

 

Pin 

Signal 

DCD, Data carrier detect/ +12V / +5V * 

RXD, Receive data 

TXD, Transmit data 

DTR, Data terminal ready 

GND, ground 

DSR, Data set ready 

RTS, Request to send 

CTS, Clear to send 

RI, Ring indicator/ +12V / +5V * 

10 

NC, Key 

Pitch: 2.54mm [YIMTEX 3362*05SANGR-10] 

*

Selected by JP4

 

 

Table 27 CN1 SIM Interface Wafer for MPCIE1 

 

Pin 

Signal Name 

UIM_PWR 

UIM_DATA 

UIM_RESET 

UIM_VPP 

UIM_CLK 

GND 

Pitch: 1.27mm [Pinrex 712-73-06TWB0]

 

 

Table 28 CN2 MPCIE Activity Indication Pin Header 

1

4

 

Pin 

Signal Name 

MPC 

MPCIE1_ACT- 

MPC 

MPCIE2_ACT- 

 

Pitch: 2.54mm [YIMTEX 3321*04SAGR (6T)] 

Содержание KEMX-6000

Страница 1: ...I KEMX 6000 User s Manual KEMX 6000 Industrial Motherboard in Mini ITX form factor with 2nd generation Intel Core i3 i5 i7 Processors and QM67 Express Chipset User s Guide...

Страница 2: ...t rights of Quanmax nor the rights of others Quanmax is a registered trademark of Quanmax All trademarks registered trademarks and trade names used in this user s guide are the property of their respe...

Страница 3: ...g Your Computer 14 Chapter 1 Introduction 17 Overview 17 Product Specifications 18 System Block Diagram 20 Mechanical Dimensions 21 Chapter 2 Hardware Settings 22 Overview 22 Jumper Settings and Pin D...

Страница 4: ...Content 4 KEMX 6000 User s Manual Chapter 5 Driver Installation 63 Appendix A DIO Digital I O Sample Code 64 Appendix B WatchDog Timer Sample Code 66...

Страница 5: ...l Dimensions 21 Figure 3 Jumper Connector 22 Figure 4 Jumper and Connector Locations 24 Figure 5 Rear Panel IO 28 Figure 6 Expansion Interfaces 45 Figure 7 Align the SO DIMM Memory Module with the onb...

Страница 6: ...LAN1 USB2 0 Port 0 1 Connector 28 Table 16 CN11 LAN2 USB2 0 Port 2 3 Connector 29 Table 17 CN12 CRT DB 15 DVI D Connector 29 Table 18 CN13 RS 232 422 485 Port 1 2 Connector 30 Table 19 HDMI Connector...

Страница 7: ...2 Table 50 SATA3 Serial ATA Port2 Connector 42 Table 51 SATA4 Serial ATA Port3 Connector 43 Table 52 SATA5 Serial ATA Port4 Connector 43 Table 53 SATA6 Serial ATA Port5 Connector 43 Table 54 USB1 USB2...

Страница 8: ...e 68 Advanced Menu SATA Configuration 55 Table 69 Advanced Menu AMT Configuration 55 Table 70 Advanced Menu USB Configuration 57 Table 71 Advanced Menu H W Monitor 58 Table 72 Advanced Menu CPU Advanc...

Страница 9: ...y harm Use extreme caution when installing or removing components Refer to the installation instructions in this user s guide for precautions and procedures If you have any questions please contact Qu...

Страница 10: ...re both connectors are correctly oriented and aligned CAUTION Do not attempt to service the system yourself except as explained in this user s guide Follow installation and troubleshooting instruction...

Страница 11: ...If possible use antistatic floor pads and workbench pads Handle components and boards with care Don t touch the components or contacts on a board Hold a board by its edges or by its metal mounting bra...

Страница 12: ...e If there is damage notify Quanmax customer service immediately Refer to Warranty Policy for the return procedure Regulatory Compliance Statements This section provides the FCC compliance statement f...

Страница 13: ...ident acts of God or other causes beyond the control of Quanmax or the manufacturer Neglect misuse and abuse shall include any installation operation or maintenance of the product other than in accord...

Страница 14: ...furnished hereunder Quanmax s liability shall in no event exceed the purchase price of the product purchased hereunder The foregoing limitation of liability shall be equally applicable to any service...

Страница 15: ...at reduced efficiency Power Protection The greatest threats to a system s supply of power are power loss power spikes and power surges caused by electrical storms which interrupt system operation and...

Страница 16: ...ower to the system for a limited amount of time depending on the UPS system UPS systems range in price from a few hundred dollars to several thousand dollars with the more expensive unit s allowing yo...

Страница 17: ...HD audio keyboard mouse and CompactFlash The KEMX 6000 is a compact high performance industrial motherboard that is ideal for a variety of applications Checklist Driver Manual CD Quick Installation G...

Страница 18: ...4 GbE controller Audio Realtek ALC888 HD audio codec 1x audio stack connector for Line Out Line In and Mic In 1x S PDIF connector on rear I O for S PDIF out supported 1x header for front panel audio s...

Страница 19: ...for power input 1x ATX 4P for CPU core power AT ATX supported Battery 1x vertical battery socket Lithium 3V ACPI ACPI supported Expansion 2x Mini PCIe slots supported 1x 2G 3G SIM card module support...

Страница 20: ...Chapter 1 20 KEMX 6000 User s Manual System Block Diagram Figure 1 Block Diagram...

Страница 21: ...Chapter 1 21 KEMX 6000 User s Manual Mechanical Dimensions A 3 51mm B 2 6mm Figure 2 Mechanical Dimensions...

Страница 22: ...Figure 3 Jumper Connector For a three pin jumper see Figure 3 the jumper setting is designated 1 2 when the jumper connects pins 1 and 2 The jumper setting is designated 2 3 when pins 2 and 3 are con...

Страница 23: ...Chapter 2 23 KEMX 6000 User s Manual Jumper Settings and Pin Definitions For jumper and connector locations please refer to the diagrams below...

Страница 24: ...Chapter 2 24 KEMX 6000 User s Manual Figure 4 Jumper and Connector Locations...

Страница 25: ...Panel Backlight Power Selection for LVDS1 JP6 Backlight Power Enable Selection for LVDS1 JP7 Backlight Power Enable Selection for LVDS2 JP8 RTC Reset Selection JP9 SRTC Reset Selection JP11 Flash Des...

Страница 26: ...t Pin 1 5V 7 9 Short Pin 1 DCD 2 2 4 Short Pin 9 12V 4 6 Short Pin 9 5V 6 8 Short Pin 9 5V 8 10 Short Pin 9 RI Pitch 2 54mm YIMTEX 3362 05SANGR Table 7 JP5 Panel Backlight Power Selection for LVDS1 2...

Страница 27: ...INREX 222 97 03GBB1 Table 10 JP8 RTC Reset Selection 1 2 Jumper Status 1 2 Open Normal Operation 1 2 Short Clear RTC CMOS Pitch 2 54mm YIMTEX 3321 02SAGR 6T Table 11 JP9 SRTC Reset Selection 1 2 Jumpe...

Страница 28: ...15 DVI D Connector CN13 RS 232 422 485 Port 1 2 Connector CN14 Optical S PDIF Output Connector HDMI1 HDMI Connector Table 14 AUDIO1 3 Stack up Azalia Audio Phone Jack Signal Name BLUE LINE IN GREEN LI...

Страница 29: ...LED on Link 100 Green LED on Link 10 or No Link LED off 2 Right Active LED Yellow Activity Yellow LED blink Table 17 CN12 CRT DB 15 DVI D Connector Signal Name Pin Pin Signal Name Red V1 V2 Green Blu...

Страница 30: ...5 Full Duplex RS 485 2 A1 DCD TX DATA TX A2 RXD RX NA RX A3 TXD TX DATA TX A4 DTR RX NA RX A5 GND GND GND GND A6 DSR NA NA NA A7 RTS NA NA NA A8 CTS NA NA NA A9 RI NA NA NA FAN YING D20HB1102112PN Not...

Страница 31: ...in Signal 1 3 3V 13 3 3V 2 3 3V 14 NC 3 GND 15 GND 4 5V 16 PS_ON 5 GND 17 GND 6 5V 18 GND 7 GND 19 GND 8 POWER OK 20 NC 9 5VSB 21 5V 10 12V 22 5V 11 12V 23 5V 12 3 3V 24 GND Pitch 4 2mm YIMTEX 576MWA2...

Страница 32: ...V 13 38 5V GND 14 39 PCSEL GND 15 40 NC GND 16 41 Reset IDE GND 17 42 IDEIORDY SDA2 18 43 DREQ IDE Address 1 19 44 DACK IDE Address 0 20 45 IDE activity IDE Data 0 21 46 PDIAG IDE Data 1 22 47 IDE Dat...

Страница 33: ...S Request to send 8 CTS Clear to send 9 RI Ring indicator 10 NC Key Pitch 2 54mm YIMTEX 3362 05SANGR 10 Table 25 COM5 RS 232 Port 5 Pin Header 9 2 1 Pin Signal 1 DCD Data carrier detect 12V 5V 2 RXD R...

Страница 34: ...quest to send 8 CTS Clear to send 9 RI Ring indicator 12V 5V 10 NC Key Pitch 2 54mm YIMTEX 3362 05SANGR 10 Selected by JP4 Table 27 CN1 SIM Interface Wafer for MPCIE1 Pin Signal Name 1 UIM_PWR 2 UIM_D...

Страница 35: ...ital Input Output Pin Header 2 10 9 1 Pin Signal Pin Signal 1 Digital Output 0 2 Digital Input 0 3 Digital Output 1 4 Digital Input 1 5 Digital Output 2 6 Digital Input 2 7 Digital Output 3 8 Digital...

Страница 36: ...Audio GND 8 Key 9 Line2 L 10 Line2_JD Pitch 2 54mm YIMTEX 3362 05SANGR 08 Table 34 CN8 Right Channel 2W Audio AMP Output Wafer Pin Signal Name 1 Speaker 2 Speaker Pitch 2 0mm YIMTEX 503PW1 02STR Tabl...

Страница 37: ...al Pin Signal 1 Reset Button 2 Speaker 3 Reset Button 4 NC 5 HDD LED 6 Internal Speaker 7 HDD LED 8 Speaker Pitch 2 54mm YIMTEX 3362 04SANGR Note Internal Buzzer is enabled when Pin6 8 is shorted Tabl...

Страница 38: ...GND 28 27 GND DDC_Clock 30 29 DDC_Data Pitch 1 25mm HIROSE DF13 30DP 1 25 24 LVDS1 panel power can be selected by JP5 Table 44 LVDS2 Secondary 24 bit 2 channel LVDS Panel Connector 29 2 30 1 Signal Na...

Страница 39: ...ound 15 16 Reserved LPC_CLK 17 18 Reserved LPC_FRAME 19 20 W_Disable Ground 21 22 PERST PERn0 23 24 3 3VSB PERp0 25 26 Ground Ground 27 28 1 5V Ground 29 30 SMB_CLK PETn0 31 32 SMB_DATA PETp0 33 34 Gr...

Страница 40: ...eserved 19 20 W_Disable Ground 21 22 PERST PERn0 23 24 3 3VSB PERp0 25 26 Ground Ground 27 28 1 5V Ground 29 30 SMB_CLK PETn0 31 32 SMB_DATA PETp0 33 34 Ground Ground 35 36 USB_D Ground 37 38 USB_D 3...

Страница 41: ...und HSIP4 36 Ground HSIN4 37 HSOP5 Ground 38 HSON5 Ground 39 Ground HSIP5 40 Ground HSIN5 41 HSOP6 Ground Pin Side B Side A 42 HSON6 Ground 43 Ground HSIP6 44 Ground HSIN6 45 HSOP7 Ground 46 HSON7 Gro...

Страница 42: ...1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND FOXCONN LD1807V S52U Table 49 SATA2 Serial ATA Port1 Connector Pin Signal Name 1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND FOXCONN LD1807V S52U Table 50 SATA3 Serial A...

Страница 43: ...1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND FOXCONN LD1807V S52U Table 52 SATA5 Serial ATA Port4 Connector Pin Signal Name 1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND FOXCONN LD1807V S52U Table 53 SATA6 Serial A...

Страница 44: ...3362 05SANGR 09 Table 55 USB2 USB2 0 Port 6 7 Pin Header 6 1 3 10 4 5 2 8 7 Pin Signal Name Pin Signal Name 1 USBVCC 2 USBVCC 3 USB_A 4 USB_B 5 USB_A 6 USB_B 7 GND 8 GND 9 KEY 10 GND Pitch 2 54mm YIM...

Страница 45: ...gure 6 Expansion Interfaces NOTE When adding or removing expansion cards make sure that you unplug the power supply first Meanwhile read the documentation for the expansion card to configure any neces...

Страница 46: ...board and insert it at a 30 degree angle into the socket Figure 7 Align the SO DIMM Memory Module with the onboard socket 4 Fully insert the module into the socket until a click is heard 5 Press down...

Страница 47: ...ase contact Quanmax AMI s ROM BIOS provides a built in Setup program which allows the user to modify the basic system configuration and hardware parameters The modified data will be stored in a batter...

Страница 48: ...stem Date Tue 03 22 2011 System Time 11 38 22 Set the Date Use Tab to switch between Data elements Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Def...

Страница 49: ...e Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save and Exit ESC Exit Version 2 10 1208 Copyright 2010 American Megatrends Inc Primary Display Options Auto IGFX PEG PCI SG Internal...

Страница 50: ...it Version 2 10 1208 Copyright 2010 American Megatrends Inc Table 61 Advanced Menu Super IO Configuration Serial Port 1 Configuration BIOS SETUP UTILITY M a i n Ad v a n c e d B o o t C h i p s e t P...

Страница 51: ...Settings Options Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Device Mode Options Standard Se...

Страница 52: ...p s e t P o w e r S e c u r i t y E x i t Serial Port 4 Configuration Serial Port Enabled Device Settings IO 2E8h IRQ 10 Change Settings Auto Enable or Disable Serial Port COM Select Screen Select Ite...

Страница 53: ...IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F0h IRQ 3 4 5 6 7 9 10 11 12 IO 2E0h IRQ 3 4 5 6 7 9 10 11 12 Ta...

Страница 54: ...bled Resume From S3 By USB Device Disabled Resume By RTC Alarm Disabled Select the highest ACPI Sleep State the System will enter when the SUSPEND button is pressed Select Screen Select Item Enter Sel...

Страница 55: ...I RAID Table 69 Advanced Menu AMT Configuration BIOS SETUP UTILITY M a i n Ad v a n c e d B o o t C h i p s e t P o w e r S e c u r i t y E x i t Intel AMT Enabled Intel AMT Setup Prompt Enabled BIOS...

Страница 56: ...e ME Confirmation Prompt Options Disabled Enabled MEBx Debug Message Output Options Disabled Enabled Un Configure ME Options Disabled Enabled Intel AMT Password Write Enabled Options Disabled Enabled...

Страница 57: ...support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications Select Screen Select Item Enter Select Change Opt...

Страница 58: ...xit ESC Exit Version 2 10 1208 Copyright 2010 American Megatrends Inc CPU Warning Temperature Options Disabled 80C 85C 90C 95C CPU Shutdown Temperature Options Disabled 80C 85C 90C 95C Table 72 Advanc...

Страница 59: ...i n A d v a n c e d B o o t S e c u r i t y S a v e E x i t Boot Configuration Full Screen LOGO Display Disabled Setup Prompt timeout 1 Bootup NumLock On Boot Option Priorities Boot Option 1 SATA FUJ...

Страница 60: ...will hav e Administrator rights Administrator Password User Password HDD Security Configuration HDD O FUJITSU MHZ2 Set Setup Administrator Password Select Screen Select Item Enter Select Change Opt F1...

Страница 61: ...u selected are saved to the CMOS RAM The CMOS RAM is sustained by an onboard backup battery and stays on even when the PC is turned off When you select this option a confirmation window appears Select...

Страница 62: ...n be used for this operation Load Failsafe Defaults Load Optimal Default values for all the setup values This option allows you to load failsafe default values for each of the parameters on the Setup...

Страница 63: ...cted the appropriate power source power it up using the power supply and install the desired operating system You can download the drivers for the KEMX 6000 from the Quanmax website at www quanmax com...

Страница 64: ...0C bit2 DO_1 IOport 0x539 bit4 DI_2 IOport 0x50C bit3 DO_2 IOport 0x539 bit5 DI_3 IOport 0x50C bit4 DO_3 IOport 0x539 bit6 DI_4 IOport 0x50C bit5 DO_4 IOport 0x53B bit0 int main int RetVal Clear DO_1...

Страница 65: ..._1 is bit 4 DO_2 is bit 5 DO_3 is bit 6 outp 0x539 RetVal RetVal inp 0x53B IO Port 0x53B RetVal RetVal 0x01 DO_4 is bit 0 outp 0x53B RetVal system pause Reading DI_1 4 RetVal inp 0x50C IO Port 0x50C R...

Страница 66: ...0x07 outp 0x2E 0x07 outp 0x2F 0x07 0xF5 bit6 If watchdog timeout event occurs this bit will be set to 1 Write a 1 to this bit will clear it to 0 outp 0x2F 0xF5 value inp 0x2F outp 0x2F value 0x40 Set...

Страница 67: ...Appendix B 67 KEMX 6000 User s Manual outp 0x2E 0xF0 outp 0x2F 0x81 bit7 WDTRST output is enabled return 0...

Отзывы: