OWNER’S MANUAL
RK2 Systems Pump
Owner’s Manual
Reliable, Energy-Efficient
Centrifugal Pumps
Important Safety Instructions
Please read all instructions completely before you install or operate your new pump. Save this manual for future reference.
General Specifications
Housing.
Corrosion resistant noryl or polypropylene.
Port size.
1½" female NPT on both inlet and discharge.
Seal.
Stationary
5
/
8
" type 6A, materials Teflon Coated 316 Stainless Steel, Silicon Carbide Faced, Buna Seat.
Motors.
NEMA 56J frame: available in
1
/
8
to
1
/
4
HP at 1725 RPM and
1
/
2
to 3 HP at 3450 RPM. Standard motor manufacturer is
Baldor, but we will substitute if availability is uncertain with equivalent motor manufacturer.
WARNINGS
1. This pump and motor unit should be installed by a qualified electrician or serviceman in accordance with all applicable
state and local codes and ordinances, and in accordance with the National Electrical Code. Improper installation may
create a mechanical or electrical hazard which could cause damage to property and which could result in serious injury or
death. Always follow the schematic on the motor for all electrical connections!
2. In order to avoid serious injury or death, always disconnect power to the motor before servicing the pump.
3. Never run the pump dry.
4. Never start the pump when the motor shaft is turning. To prevent unwanted reverse motor rotation, install a swing type check valve.
5. If you aren’t competent to install the pump, get help from a qualified source.
6. Maintain a minimum flow rate of at least two gallons per minute.
7. Visually inspect the pump and motor at least once a month. If there is any leakage from the shaft seal, replace it at once. The seal faces
wear (just like car tires) and must be replaced periodically. For critical applications, replace the shaft seal yearly.
8. The motor leads must be energized in the correct order. If you are not sure of the sequence
of your incoming supply line, remove the volute from the pump, connect the power and check
rotation. When the rotation is correct, reinstall the volute. Do not test with volute in place!
Never test rotation by bumping a switch!!! This will destroy the pump and void the warranty!!!!
If it is incorrect, exchange any two of the connected leads and retest.