Quality Heating PRF-78 Скачать руководство пользователя страница 2

Installing your thermostat

 

8. Setting functions and options

During power off, press and hold M and       at the

same time for 5 sec. to system functions.  Then press 

M to change the different items.  All the settings will 

confirm automatically when power is on. Press     

to confirm,     to cancel.

 

Wiring your thermostat

WARNING: 

 

Please arrange the professional technician 

to install this product according to installation drawing and 

instruction. 

RISK OF ELECTRICAL SHOCK.

 

Disconnect power supply 

before making electrical connection. Contact with components 

carrying hazardous voltage can cause electrical shock and may 

result in severe personal injury or death.instruction. 

Press      to time setting of the second period.

Press      to temperature setting of the second period.

Press      to time setting of the third period.

Press      to temperature setting of the third period.

Press      to time setting of the fourth period.

Press      to temperature setting of the fourth period.

Press      to time setting of the fifth period.

Press      to temperature setting of the fifth period.

Press      to time setting of the sixth period.

Press      to temperature setting of the sixth period.

Press      to Sat. & Sun setting.

The above is the 5+2 weekly programmable.

The 6+1 weekly programmable please refer to the 

above setting.  Please change 5+2 or 6+1 in the high

senior options 7.

Factory default setting of period time and temperature

Sat & Sun

AC95~230V

IP20

N

L

1

2

3 4

M

Close

Open

5
6

NTC

GA

L1

N1

LOAD

IP20

N

L

RS485+

(Red)

RS485-

(White)

1

2

3 4

NTC

5
6

GB

Remark: 

GA is for water heating; 

GB is for electric heating;

NTC and RS485 is optional.

Wiring your thermostat

 

     

 

www.elektrische-vloerverwarming.nl

Remark: all values please press         for the adjustment.

                     Remark:  1. When the sensor type is AL, room temp. and floor temp.

                                   could be changed by pressing and holding      for 3 second.

2. Press and hold         for 5 sec. to lock/unlock the button.                          

3. Connect the LCD board into the wall plate.

4. Finished.

(Fig 4)

(Fig 3)

RS485+

(Red)

RS485-

(White)

Code  Func on 

Se ng and op ons 

Default 

1

 

Temperature 
compensa on 

-9 to +9

  (for internal sensor) 

2

 

Deadzone 
Temperature 

1 ~ 5

3

 

Sensor types 

In

Internal Sensor

to control or limit the temperature

 

Ex

External Sensor

to control or limit the temperature

 

AL

Internal/ External Sensor

Internal sensor to control temperature, 

external sensor to limit temperature

 

Remark: Please make sure the right sensor. If choose the wrong or bad 
one, LCD will display Err, the thermostat will stop working un l the 
failure is solved. 

In 

4

 

Low temperature 
protec on se ng. 

5-10

. When up to Max. 10

, press     . When display” 

. W hen display“

- -”, cancel this 

func on. When the detec ng temp. is lower than the low temperature 
protec on se ng, hea ng equipment will be forced to open. 

5

 

High temperature 
protec on se ng. 

35-70

. When down to Max. 35

, press  . When display“- -”, cancel 

this func on. When the detec ng temp. is higher than the high 
temperature protec on se ng, hea ng equipment will be forced to 
close. 

45

 

6

 

Bu on locking 

0: All bu ons are locked except power bu on. 
1

All bu ons are locked. 

7

1

 

Weekend se ng 
(op onal) 

0: Two-day Weekend

12345 and 67 

1: One-day Weekend

123456 and 7. This func on is just available for 

programmable thermostat. 

7

2

 

Communica on 
Protocol (op onal) 

0: The equipment could not be controlled by computer (communica on 
protocol) 
1:  The  equipment  could  be  controlled  by  computer  (communica on 
protocol). This func on is just available for RS485/Modbus thermostat. 

8

 

12/24 hours 

12h: 12 hours 
24h: 24 hours   

24h 

Backlight Time 

3-99 seconds 

10 

10 

Intelligent Recovery 

00: Programmable on  me 
01: Intelligent recovery. (system starts 30min. early when setpoint is 
reached by start of program period). 

00 

11 

Return to factory 
se ng 

Press        to adjust rst0    to rst9.    Press        again return to factory 
se ng. 

 

12 

485 Communica on 
IP high address 
(op onal) 

00--FF 

00  

13 

485 Communica on 
IP low address 
(op onal) 

01--FF 

01 

 

   

     

AC95~230V

This product is suitable for standard 86mm wall 

box or european 60mm round box.

1. Connect the wire of power and other equipment into 

    the terminals.

(Fig 1)

(Fig 2)

2. Fix the wall plate into the wall box by a screwdriver.