![Quality Cable & Electronics Indoor Fiber Optic Receiver Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/quality-cable-and-electronics/indoor-fiber-optic-receiver/indoor-fiber-optic-receiver_user-manual_3394643005.webp)
5
INDOOR FIBER OPTIC RECEIVER
INSTALLATION AND ADJUSTMENT
1. Power Connection
Under normal circumstances, after the power is connected. Status light lits red.
2. Fiber Connection
Cut off the power and take down the bolt in Fiber Input Port then perform the following steps:
•
Carefully remove the protective cap from the SC/APC connector.
•
Clean the end of the connector with a lint free tissue moistened with alcohol.
•
Insert the connector into the receptacle of the SC/APC adapter.
•
Power on, the status light in front panel lits green when the input power is above -8dBm.
Otherwise, it lits red.
3. Test points
On the front panel there are two points for the use of testing input power by a multimeter.
4. Cable Connection
Connect the cables accordingly.
Important: all the input or output ports (not including the test ports) not in use should be
connected to 75
Ω
resistance.
5. Optical Power Monitoring
Status light shows when the input optical power is lower than
–
8dBm. In this case, you should
check the optical link, the SC/APC connector and the output optical power of the transmitter.
6. Technical Support
Any technical questions or operation problems please resort to the supplier.