Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12
24
F. Vent Diagrams
Figure 7.4
Note:
There MUST be a 25%
reduction in total H when
using fl ex vent except when
using the simple up and out
installation (see Figure 5.3).
Note:
Use SLP Series
components only.
Top Vent - Horizontal Termination
Venting with 1 elbow (NG)
V
1
Minimum
H
1
Maximum
90 Elbow
1 ft.
305 mm
1/2 ft.
152 mm
2 ft.
610 mm
1-1/2 ft.
457 mm
3 ft.
914 mm
2-1/2 ft.
762 mm
5 ft.
1.5 m
3-1/2 ft.
1.1 m
7 ft.
2.1 m
4-1/2 ft.
1.4 m
15 ft.
4.6 m
H
1
MAX. =15 ft. (4.6 m)
V
1
+ H
1
MAX. = 40 ft. (12.2 m)
V
1
Minimum
H
1
Maximum
90 Elbow
Not allowed
1/2 ft.
152 mm
1 ft.
305 mm
1-1/2 ft.
457 mm
3 ft.
914 mm
2-1/2 ft.
762 mm
5 ft.
1.5 m
3-1/2 ft.
1.1 m
7 ft.
2.1 m
4-1/2 ft.
1.4 m
15 ft.
4.6 m
H
1
MAX. =15 ft. (4.6 m)
V
1
+ H
1
MAX. = 40 ft. (12.2 m)
Top Vent - Horizontal Termination
Venting with 1 elbow (Propane)
H
1
V
1