Hearth & Home Technologies LIMITED WARRANTY

Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, 
pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or 
Canada.  Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts. 

Warranty Period

HHT Manufactured Appliances and Venting

Components Covered

Parts

Labor

Gas

Wood

Pellet

EPA 

Wood

Electric

 Venting

 

1  Year

X

X

X

X

X

X

All Parts and Material Except 

as covered by Conditions, 

Exclusion, and Limitations 

listed 

 

2 years

 

 

X

X

 

 

Igniters, Electronic Compo-

nents, and Glass

X

X

X

X

 

 

Blowers

 X

    

Molded 

Refractory 

Panels

 

years

  X

   

Firepots

 

5 years

3 years

 

 

X

X

 

 

Castings & Baffles

 

7 years

3 years

 

X

X

X

 

 

Firebox, HHT Chimney, Termi-

nation & Heat Exchanger

 

10 

years

year

X

     

Burners, Logs & Refractory

 

Limited 
Lifetime

1 year

X

 

     Firebox 

Heat 

Exchanger 

 

90 Days

X

X

X

X

X

X

All Replacement Parts

 

See Conditions, Exclusions, and limitations.            9-01-08

CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY

 

This warranty applies to the original owner and is transferable up to two years from date of purchase to the new 
homeowner, provided the purchase was made through an authorized dealer or distributor of HHT, and the appliance 
remains in its original place of installation.

 

The maximum amount recoverable under this warranty is limited to the purchase price of the product.

 

In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product.

 

Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home 
is not covered under this warranty.

 

This limited warranty does not extend to or include surface finish on the appliance or terminations, door gasketing, 
glass gasketing, glass discoloration, firebrick, pellet logs, kaowool or other ceramic insulating materials.  Rust and/or 
corrosion on any of the metal surfaces, cast iron components, baffles, firepots, doors, or firebox area are not covered 
by this warranty.

4021-645A 09-01-08

Warranty Policy

Содержание Quadra-Fire CUMBGAP-MBK

Страница 1: ...rn wet or green wood Store wood in a dry location 6 DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Do not burn treated wood or wood with salt driftwood etc Burning materials other than wood including charcoal under adverse conditions may generate carbon monoxide in the home resulting in illness or possible death 7 Do not permit creosote or soot to accumulate excessi...

Страница 2: ...Rating 115 VAC 1 2 Amps 60 Hz Route power cord away from unit Do not route cord under or in front of appliance DANGER Risk of electrical shock Disconnect power supply before servicing Replace glass only with 5mm ceramic available from your dealer Do not use grate or elevate fire Build wood fire directly on firebrick Do not overfire if heater or chimney connector glows you are overfiring Operate on...

Страница 3: ...ement 25 26 Care cleaning of plated surfaces 26 Door gasket door handle assembly 26 Brick replacement 27 Baffle removal installation 27 PARTS DIAGRAM 28 SERVICE PARTS ACCESSORIES 29 30 SERVICE MAINTENANCE LOG 31 WARRANTY POLICY 32 CONTACT INFORMATION 36 TABLE OF CONTENTS PRE USE CHECK LIST CAUTION DO NOT TILT THE UNIT ON THE CAST IRON LEGS Lift the unit upright and place it into position on the floo...

Страница 4: ...ee pages 13 14 It is intended to keep the walls from igniting CHIMNEY SYSTEMS A APPROVED MASONRY see specifications on page 12 with at least 5 8 16mm fire clay lining joined with refractory cement or other listed system suitable for use with wood stoves B PREFABRICATED 6 152mm listed high temperature UL 103 HT or ULC S629 chimney Components required by manufacturers for installation such as the chim...

Страница 5: ...e equipped with a spark arrestor and the referenced clearances Use only double wall connector pipe Dura Vent DVL Selkirk metalbestos DS Security DL double wall connector or any listed double wall connector pipe In Canada must comply with CAN ULC S629 for the 650 C Factory built chimney SERIAL NUMBER LABEL IS LOCATED ON THE BACK OF THE STOVE TOP VIEW SIDE VIEW WITH FUEL DOOR 27 1 4 692mm 18 1 8 460...

Страница 6: ...d factory built Class A chimney or a masonry chimney Mobile Home must be equipped with a spark arrestor Double Wall USA 12 305 10 5 267 25 635 26 660 15 381 16 406 N A N A N A N A 44 1118 N A Double Wall Canada 12 305 10 5 267 25 635 28 711 15 381 18 457 N A N A N A N A 44 1118 N A REAR VENT INSTALLATIONS INAMASONRY FIREPLACE OR THROUGH THE WALL HORIZONTAL FLUE HEAT SHIELD PART HTSHLD 7006 REQUIRE...

Страница 7: ...om the sides and rear of the stove See exception below EXCEPTION Non combustible floor protections must extend beneath the flue pipe when installed with horizontal venting and extend 2 51mm beyond each side Minimum 16 406mm from fuel loading door 8 200mm USA 44 7 8 1140mm Minimum 39 1 8 994mm Minimum Fuel loading doors Front Side 8 200mm Minimum 16 406mm from fuel loading door CANADA 1371mm 54 Minim...

Страница 8: ...neath it The R value of a material must be equal or larger then the required R value to be accept able Converting k to R Divide 1 by k and multiply the results times the thickness in inch es of the material R 1 k x inches of thickness Converting R to k Divide the inches of thickness by R k inches of thickness R Calculatons Example Floor protection requires k value of 0 84 and 3 4 inch thick Altern...

Страница 9: ...ce You must first decide where you are locating your stove and determine if you meet the minimum required clearances from combustibles for loading wood into the firebox from the side door If you do not meet the clearances found on pages 6 8 leave the door locked in place If you unlock the door without meeting the minimum requried clearances YOU WILL VOID YOUR WARRANTY AND ASSUME ALL RESPONSIBILITY I...

Страница 10: ...ad screws from the rear shield 2 on each side lift rear heat shield off and set aside 3 Remove 1 bolt from each side of the flue collar using a Phillps head screwdriver and 7 16 wrench 4 Turn flue collar to horizontal position Inspect sealant to ensure a leak free application Re attach bolts 5 Re attach the rear heat shield 6 Attach required accessory Horizontal Flue Shield with screws provided Figu...

Страница 11: ... chimney not including chimney cap Availability of combustion air A source of air oxygen is necessary in order for combustion to take place It is impor tant to realize that whatever combustion air is consumed by the fire must be replaced If you are using room air the air is replaced via air leakage that occurs around windows and under doors etc However in most newly constructed houses mobile homes ...

Страница 12: ...to be no more than 3 times the cross sectional area of the flue collar of the stove 28 x 3 84 square inches It is recom mended that a chimney with a larger diameter be relined since the oversized flue can cause poor performance and contribute to the accumulation of creosote See page 11 for more information about troubleshooting draft problems CAUTION DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVIN...

Страница 13: ...o the chimney must leave a minimum 18 457mm vertical clearance between the connector pipe and the ceiling to prevent the ceiling from catching fire Measure as shown in Figure 13A Cut an opening in the wall large enough to accommodate the outside dimension of the chimney section plus the minimum air space specified by its manufacturer It may be necessary to cut the wall studs and install a header and...

Страница 14: ...Clearance to Wall Spacer and Combustibles 2 51mm Chimney Section Trim Collar Chimney Section with 2 51mm Clearance to Combustibles Chimney Connector Fire Clay Flue Liner with Airspace Masonry Chimney Wall Band to Secure Chimney Section Wood Studs Used for Framing Spaced 2 51mm clearance from Masonry Chimney Wall Spacer Figure 14B Figure 14A CONNECTION TO A MASONRY FIREPLACE There are several kits ...

Страница 15: ...e the required height above the roof or other obstruction for safety and for proper draft operation The require ment is that the chimney must be at least 3 ft 91cm higher than the highest point where it passes through the roof and at least 2 ft 61cm higher than the highest part of the roof or structure that is within 10 ft 305cm of the chimney measured horizontally See page 11 In Canada when using...

Страница 16: ...nnected to a 6 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS Floor protection referenced on page 8 must be followed 8 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure 9 Follow the chimney and chimney connector manufacturer s instructions when installing the...

Страница 17: ...ed control clockwise to decrease the speed At full clockwise the blower should blow gently but should not stop 1 With the unit plugged in turn the speed control knob to slow full clockwise 2 With a small screwdriver adjust the blower speed by turning the adjustment mechanism through the hole on the side of the speed control 3 Adjust the speed so the blower runs slowly but does not stop Turn clockw...

Страница 18: ...at the bottom of the tem plate HAND BEND 1 Bend the diverter to match the same degree bend as in the template HAND BEND 2 Bend the diverter 90 to complete the process Place diverter on tem plate to confirm the bends match the template Baffle Diverter is shipped inside firebox WARNING Risk of Fire Required on all rear horizontal installations Excessive smoke or flame spillage into the room may occur ...

Страница 19: ...oth doors 2 Hold the diverter in a vertical position with the straight edge going in first and then rotate it to the inside of the firebox as you slide the bent diverter over the ceramic blanket 3 Place in position as shown in diagram below The front edge of the diverter will rest on the front edge of the manifold chamber in a flush position The back edge will butt up against the back slanted corner ...

Страница 20: ... it is used during the kindling stage of burning It must be closed pulled out after the first 5 to 15 minutes Figure 21A 2nd STAGE The next stage of burning the secondary stage is the period when the wood gives off flammable gases which burn above the fuel with bright flames During this stage of burning it is very important that the flames be maintained and not allowed to go out This will ensure the c...

Страница 21: ...hould do so responsibly To do this we need to learn to burn our stoves in the cleanest way possible Doing this will allow us to continue using our wood stoves for many years to come START UP AIR SYSTEM The combustion air enters at the rear of the firebox through the rear air tubes This air supply is controlled by the Start up Air Control For more air push control IN for less air pull control OUT PR...

Страница 22: ...ure as your stove heats You will notice an odor and perhaps see some vapor rise from the stove surface this is normal We recommend that you open a window until the odor dissipates and paint is cured NOTE Stove should be run full open for 15 minutes a day to keep air passages clean WARNING ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT DURING START UPAND RE FUEL ING OR WHEN U...

Страница 23: ... placement and replace baffle com ponents if damaged or missing CORRECT BAFFLE BLANKET PLACEMENT Ceramic Blanket and Baffle Board are NOT in contact with the back of the firebox Ceramic Blanket is NOT in contact with the back of the firebox and NOT even with the Baf fle Board in the front Ceramic Blanket is bunched up at the back of the firebox and NOT even with the Baffle Board in the front Ceramic Blan...

Страница 24: ...blower should be left off until a good burn is established then turned on at your desired setting 4 Low burn setting The blower tends to cool off the stove Leave blower off until burn is well established Then turn on at your desired rate 5 The highest blower speed is obtained by turning the speed control on and then adjusting counterclockwise towards OFF as far as possible without turning the blow...

Страница 25: ... should remove the built up coating If the deposits on the glass are not very heavy normal glass cleaners work well Heavier deposits may be removed by using a damp cloth dipped in wood ashes or by using a com mercially available oven cleaner After using an oven cleaner it is advisable to remove any residue with a glass cleaner or soap and water Oven cleaner left on during the next firing can perman...

Страница 26: ... soft rag glass cleaner and a paper towel or vinegar and a paper towel to remove the oils DO NOT use abrasive cleaners If not cleaned properly prior to lighting the first fire the oils can cause permanent stains The plating will be cured upon firing of the stove and oils will no longer affect the finish Subsequently little maintenance is then required Wipe clean as needed with a soft towel FRONT DOOR ...

Страница 27: ...etrating oil for at least 15 minutes before trying to remove them 4 To remove manifold tube slide the tube to one side until one end is out of its hole Then while lifting that end of the fiber board baffle pull tube up over the air channel and out of hole at the other end 5 Slide fiber board baffle forward to front of stove and straight out through door See Figure 27B 6 To install the fiber board baffle...

Страница 28: ...R Page 28 September 1 2008 Cumberland Gap Wood Stove 7006 188E 14 1 4 23 0 14 0 5 0 4 3 8 Ceramic Blanket 10 15 9 8 6 16 3 13 12 4 7 14 17 2 5 18 1 11 19 Part number list on following page Parts Diagram ...

Страница 29: ...06 155MBK 16 Door Left Front Porcelain specify color 7006 155POR 3 Door Right Front Matte Black 7006 154MBK 3 Door Right Front Porcelain specify color 7006 154POR 6 Door Side Matte Black 7006 225MBK 6 Door Side Porcelain specify color 7006 225POR 11 Face Matte Black 7006 223MBK 11 Face Porcelain specific color 7006 223POR 8 Flue Transition 7006 019 Gasket Rope Ash Removal Door 3 8 medium density 10...

Страница 30: ...450 Rivnut Repair Kit RIVNUT REPAIR 4 Side Right Cast Matte Black 7006 151MBK 4 Side Right Cast Porcelain specific color 7006 151POR 12 Side Left Cast Matte Black 7006 152MBK 12 Side Left Cast Porcelain specific color 7006 152POR 10 Top Cast Matte Black 7006 153MBK 10 Top Cast Porcelain specific color 7006 153POR Service Parts Accessories IMPORTANT THIS IS DATED INFORMATION The most current informati...

Страница 31: ...Page 31 Cumberland Gap Wood Stove R September 1 2008 7006 188E Date of Service Performed By Description of Service Service Maintenance Log ...

Страница 32: ...ox Heat Exchanger 90 Days X X X X X X All Replacement Parts See Conditions Exclusions and limitations 9 01 08 CONDITIONS EXCLUSIONS LIMITATION OF LIABILITY This warranty applies to the original owner and is transferable up to two years from date of purchase to the new homeowner provided the purchase was made through an authorized dealer or distributor of HHT and the appliance remains in its origin...

Страница 33: ...if the appliance has been over fired or operated in atmospheres contaminated by chlorine fluo rine or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation or there is any damage to the appliance or other components due to water or weather damage which is the result of but not limited to improper chimney or venting installation HHT s liability under this ...

Страница 34: ...R Page 34 September 1 2008 Cumberland Gap Wood Stove 7006 188E This page intentionally left blank ...

Страница 35: ...Page 35 Cumberland Gap Wood Stove R September 1 2008 7006 188E This page intentionally left blank ...

Страница 36: ...502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 D320652 D445174 D462436 Canada 1297749 2195264 2225408 or other U S and foreign patents pending Hearth Home Technologies 1445 North Highway Colville WA 99114 Division of HNI INDUSTRIES CONTACT INFORMATION Please contact your Quadra Fire dealer with any que...

Отзывы: