background image

 6 

 

 

 

 

                        7036-188J 

 

 

 

       October 3, 2017

MT VERNON AE INSERT

E. Install Checklist

Appliance Install                                                                                              

Appliance is leveled and connector is secured to appliance.

Hearth extension size/height decided. 

Outside air kit installed.

Floor protection requirements have been met.

If appliance is connected to a masonry chimney, it should be cleaned and 

inspected by a professional. If installed to a factory built metal chimney, the 

chimney must be installed according to the manufacturer’s instructions and 

clearances. 

Chimney

Chimney installed, locked and secured in place with proper clearance. 

Chimney meets recommended height requirements (14-16 feet).

Terminations installed and sealed.

Clearances

Combustible materials not installed in non-combustible areas.

Mantels and wall projections comply with installation manual requirements. 
Protective hearth strips and hearth extension installed per manual requirements.

Appliance Setup

All packaging and protective materials removed. 

All labels have been removed from the door.

All packaging materials are removed from inside/under the appliance.

Manual bag and all of its contents are removed from inside/under the appliance

     and given to the party responsible for use and operation.

ATTENTION INSTALLER:

Follow this Standard Work Checklist

This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.

Customer:   __________________________________________________________________________

Date Installed: __________________________________________________________________________

Lot/Address:  __________________________________________________________________________

Location of Appliance: 

______________________________________________________________

Installer: 

__________________________________________________________________________

Dealer/ Distributor Phone #:  ______________________________________________________________

Serial #: 

__________________________________________________________________________

Model :             __________________________________________________________________________

 

WARNING! Risk of Fire or Explosion! 

Hearth & Home Technologies recommends the following:

• That this checklist remain visible at all times on the appliance until the installation is complete.

Comments: 

Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:

Comments communicated to party responsible                                                         by                                             on                    
 

 

   

          

(Builder/Gen. Contractor)                           (Installer)                        (Date)

YES       IF NO, WHY?

 

Содержание MTVERNINSAE-MBK

Страница 1: ...oline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warr...

Страница 2: ...4 E Chimney and Exhaust Connection 14 F Equivalent Feet of Pipe 15 G Pipe Selection Chart 15 5 Venting Systems 16 A Full Reline With Outside Air Horizontal 16 B Full Reline With Outside Air Vertical 1...

Страница 3: ...appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operati...

Страница 4: ...t be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney offsets Place the appliance where there will be a clear passage for a Li...

Страница 5: ...rol is an integral part of the appliance No other wall control or thermostat can be substituted D Inspect Appliance and Components Open the appliance and remove all the parts and articles packed insid...

Страница 6: ...o the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the...

Страница 7: ...nd Set 36 5 8 932 15 380 13 1 8 333 12 7 8 327 32 814 23 7 8 606 3 5 8 92 3 5 8 92 23 7 8 606 32 813 13 330 15 1 8 384 13 330 36 3 4 932 45 1143 34 1 2 876 50 1270 33 838 29 3 4 756 23 7 8 605 11 3 4...

Страница 8: ...earances to Combustibles UL and ULC Fire Risk Comply with all minimum clearances to combusti bles as specified WARNING Failure to comply may cause house fire Figure 8 1 Built in Appliance Framing Dime...

Страница 9: ...010mm Figure 9 2 HEARTH EXTENSION No thermal protection required Ember protection only If mantel depth is 10 inches or less than the height from the hearth to the bottom of the mantel is 39 3 4 inches...

Страница 10: ...BURNING FIREPLACE 250 2061 Heath Home Technologies 250 2061 5 5 in width x 2 in height NON ANOD ALUM BLACK LETTERS ON SILVER with 1 8 in holes on both sides Black letters Figure 10 1 If the hearth ext...

Страница 11: ...himney cap must be re installed after installing the approved chimney liner meeting type UL 103 HT requirements 2100 F per UL 1777 If the chimney is not listed as meeting HT requirements or if the fac...

Страница 12: ...es and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in t...

Страница 13: ...space in which the pellet appliance is located Consult with your local HVAC professional to determine the ventilation demands for your house Vent Configurations When installing a pellet appliance wit...

Страница 14: ...imney NOTICE HEARTH Home Technologies assumes no responsibility for the improper performance of the chimney system caused by Inadequate draft due to environmental conditions Down drafts Tight sealing...

Страница 15: ...829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe calculate...

Страница 16: ...raw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations d...

Страница 17: ...ide Air Vertical Figure 17 1 Outside Air Termination at Chimney Top Vertical 305mm min below 305mm min above NOTE Use metal plate around exhaust vent pipe and seal all edges with non flammable insula...

Страница 18: ...g on outside of house 3 Use wire ties to secure flex pipe to collar assembly 4 Slide trim ring over flex pipe and run pipe through wall 5 Attach flex pipe not included to outside termination cap with...

Страница 19: ...then release the latch The latch hooks onto a bracket to hold the side in place Bend tabs down Shipped flat from the factory Figure 19 2 9 attachment holes 3 on each side and 3 in the front Figure 19...

Страница 20: ...tabs down Included in Surround Kit 2 side panels left and right 1 panel top 1 fastener package Included in Cast Trim Kit 2 cast trim legs left and right 1 cast trim header 2 cast trim footers left an...

Страница 21: ...Control Thermostat Installation 1 When mounting the wall control thermostat on the wall be sure to follow your wall control s installation instruc tions carefully NOTE The wall control thermostat sho...

Страница 22: ...0 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 22 1 CAUTION Never draw outside combust...

Страница 23: ...3 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim No Longer Available SP MTVS GD Component Pack 7036 042 Trim Panel Set Gold SRV250 4660 Surround St...

Страница 24: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Отзывы: