Page 8
7036-135F
August 27, 2009
R
Mt. Vernon Pellet Insert (AE)
Fire Risk.
Comply with all minimum
clearances to combustibles as
specifi ed.
WARNING
Failure to comply may cause
house fi re.
NOTE:
•
Illustrations refl ect typical installations
and are FOR DESIGN PURPOSES
ONLY.
•
Illustrations/diagrams are not drawn to
scale.
•
Actual installation may vary due to
individual design preference.
A
C
B
D
C
B
0 inch Clearance To Exposed Section And Face Trim
E
B. Clearance To Combustibles, UL and ULC
Location
Confi guration
Inches
Millimeters
A
Top of Hopper
Top or Rent Vent
3
76
B
Side of Outside Skin
Top or Rear Vent
2
51
C
Back of Hopper
Top Vent
7-1/2
191
Rear Vent
2-3/4
70
D
Vent Pipe to Combustible
Top or Rear Vent
3
76
E
Cast Side to Side Wall
Top or Rear Vent
6
152
Outside Air
Top/Rear Vent
3 in. (76mm)
Back of Hopper
2.75 in. (70mm)
6 in
(152mm)
Built-in Unit - Rear Vent with Outside Air
Figure 8.1
Figure 8.2
Built-in Unit - Rear Vent