background image

Page  46

7036-135E

September 1, 2008

R

Mt. Vernon Pellet Insert (AE)

Item No.

Appliance

Part No.

Mt. Vernon Insert, Advanced Energy (AE), Matte Black

MTVERNINSAE-MBK

Mt. Vernon Insert, Advanced Energy (AE), Powder Coat, Sienna Bronze

MTVERNINSAE-CSB

Mt. Vernon Insert, Advanced Energy (AE), Powder Coat, Willow

MTVERNINSAE-CWL

Mt. Vernon Insert, Advanced Energy (AE), Porcelain, Mahogany

MTVERNINSAE-PMH

Rivet, Button Head, Gold

Qty 1:  72171
Qty 2:  844-5750

Rivnut Repair Kit, 1/4-20

RIVNUT-REPAIR

Screw 1/4-20 x 3/8”, Qty: 24 

7000-401/24

Screw 1/4-20 x 5/8”, Qty: 24

7000-398/24

53

Sensor, Overheat  (Snap Disc #3, Manual Re-set))

230-1290

Sensor, Fuel Level

7000-380

67

Side Window Backer

414-0280

66

Side, Matte Black (left & right are interchangeable)

7036-103MBK

66

Side, Porcelain, Mahogany, (left & right are interchangeable)

7036-103PMH

66

Side, Powder Coat, Sienna Bronze, (left & right are interchangeable)

7036-103CSB

66

Side, Powder Coat, Willow, (left & right are interchangeable)

7036-103CWL

13

Spring, Auto-Clean, Qty: 4

7000-299/4

43

Switch, Magnetic

7000-375

30

Switch, Micro, Normally Open

7000-327

55

Switch, Optical Assembly

7034-038

17

Thermocouple, Firepot

SRV7000-334

19

Thermocouple Cover

SRV7034-186

Thermocouple Ring Mount

SRV7000-381

Thermostat Wire, 3 Conductor

7000-409

62

Top, Matte Black

7036-101MBK

62

Top, Porcelain, Mahogany

7036-101PMH

62

Top, Powder Coat, Sienna Bronze

7036-101CSB

62

Top, Powder Coat, Willow

7036-101CWL

Top Mount, Left

SRV7036-117

Top Mount, Right

SRV7036-115

Vacuum Hose

7000-373

44

Vacuum Switch

SRV7000-166

Wall Control, Thermostat, Programmable

SRV7000-451

Wire Harness, Auger, Auto Clean, Vacuum Switch

SRV7034-191

Wire Harness, Battery Back-up

7034-202

Wire Harness, Convection Blower

7034-219

Wire Harness, Door, Hopper

SRV7034-192

Wire Harness, Igniter (Heating Element)

SRV7034-199

Wire Harness, Overheat Sensor

7034-193

Wire Harness, Power Out, AC Current

7034-220

Wire Harness, Power Out, DC Current

7034-221

Wire Harness, Power (Supply) Receptacle

SRV7034-233

Wire Harness, Thermostat

SRV7034-200

Item No.

Service Parts

Part No.

Содержание MT VERNON Pellet Insert Advanced Energy (AE)...

Страница 1: ...am mable vapors and liquids in the vicinity of this or any other appliance Do not over re If any external part starts to glow you are over ring Reduce feed rate Over ring will void your warranty Comp...

Страница 2: ...CLOTHINGAND FURNITUREAWAY CONTACT MAY CAUSE SKIN BURNS SEENAMEPLATEANDINSTRUCTIONS Operate this unit with fuel hopper lid closed Failure to do so may result in emissions products combustion from the...

Страница 3: ...without Outside Air 15 B Direct Connect witht Outside Air 15 C Full Reline with Outside Air 16 Section 6 Mobile Home Installation 17 Section 7 Appliance Set Up A Leveling System 18 B Outside Air Kit 1...

Страница 4: ...RD C 1482 D Electrical Rating 115 VAC 60 Hz Start 5 Amps Run 1 25 Amps BTU output will vary depending on the brand of fuel you use in your appliance Consult your Quadra Fire dealer for best results NO...

Страница 5: ...loca tion of the vent termination CAUTION If burning shelled field corn you must use ap proved venting specifically designed for corn to prevent corro sion or degradation Follow the instructions from...

Страница 6: ...e heating season Ensure adequate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appli...

Страница 7: ...Measure Plumb Line Level Framing Material Hi temp Caulking Material Gloves Safety Glasses Framing Square Electric Drill Bits 1 4 1 4 Self Tapping Screws May also need Vent Support Straps Venting Paint...

Страница 8: ...th Basic Surround Panel Set Figure 8 1 Top View Figure 8 2 Side View 26 1 4 in 667mm 13 1 8 in 333mm 15 in 382mm 23 7 8 in 606mm 32 in 812mm 8 1 8 in 206mm 2 3 8 in 59mm C L 29 3 4 in 756mm 23 7 8 in...

Страница 9: ...sign preference A C B D C B 0 inch Clearance To Exposed Section And Face Trim E B Clearance To Combustibles UL and ULC Location Con guration Inches Millimeters A Top of Hopper Top or Rent Vent 3 76 B...

Страница 10: ...2 Figure 10 3 C Masonry and Zero Clearance Fireplaces Location Inches Millimeters D Floor protection hearth extension from door opening 6 152 E Floor protection to the side of door opening 6 152 D Fl...

Страница 11: ...e the installation of the insert only when a 1 4 inch 6mm airspace is provided between the insert and the oor of outer wrap Figure 11 1 Measure and mark the metal oor for cutting With a drill make a s...

Страница 12: ...line of regulator I 36 in USA 72 in Canada Clearance to service regulator vent outlet J 12 in 48 in no OAK Clearance to non mechanical air supply inlet to the building or the combustions air inlet to...

Страница 13: ...e approved venting specifically designed for corn Follow the instructions from the venting manufacturer Fire Risk Only LISTED venting components may be used NO OTHER vent components may be used Substi...

Страница 14: ...you reach your altitude above sea level If you fall below the diagonal line 3 or 4 inch 76 to 102mm pipe may be used If it is anywhere above the diagonal line a 4 inch 102mm diameter pipe is required...

Страница 15: ...mum standard of NFPA 211 Factory built chimney must be 6 inch 152mm UL103 HT WARNING CAUTION Never draw outside combustion air from Wall oor or ceiling cavity Enclosed space such as an attic or garage...

Страница 16: ...not use high temperature caulk ing materials to seal an edge to prevent future serviceabilit NOTE Check clearances carefully for this type of instal lation to ensure adequate room for outside air vent...

Страница 17: ...ounding device 5 Refer to Clearances to Combustibles and oor pro tection requirements on pages 9 10 for listings to combustibles and appropriate chimney systems 6 Use silicone to create an effective v...

Страница 18: ...assembly 4 Slide trim ring over ex pipe and run pipe through wall 5 Attach ex pipe not included to outside termination cap with second wire tie 6 Secure termination cap to outside surface 7 Secure tr...

Страница 19: ...t to damage the nish 3 To replace the side set the bottom in rst Squeeze the latch in an open position Place the cast side into posi tion and then release the latch The latch hooks onto a bracket to h...

Страница 20: ...Install Cast Trim Header 2 Bend tabs down Included in Panel Kit 2 side panels left and right 1 panel top 1 fastener package Included in Cast Trim Kit 2 cast trim legs left and right 1 cast trim heade...

Страница 21: ...han shown here can cause excessive heat and shall void the appliance warranty Figure 21 1 Figure 21 2 Log fits over screws Left Log Log has indentations on the bottom to fit over the screw heads Log r...

Страница 22: ...y NOTE The wall control thermostat should be mounted on an inside wall and not in direct line with the appliance convection air NOTE If the wall control thermostat is located too close to the applianc...

Страница 23: ...shelled eld corn wheat and black oil sun ower seeds Burning of any other type of fuel voids your warranty CAUTION A Fuel Size Material and Storage 1 Wood Pellets Wood pellets are made from sawdust or...

Страница 24: ...t manual for detailed instructions CAUTION Tip of thermocouple must be in contact with the inside end of the thermocouple cover Missed ignitions can occur Figure 24 3 3 Auto Clean Firepot System Your...

Страница 25: ...N G Ignition Cycles The Advanced Energy engine is controlled by the digital wall control The digital display on the wall control will tell you what your appliance is doing in the upper left corner abo...

Страница 26: ...ding fuel and allow the re to dimin ish The convection blower will continue to run until the appliance cools to appropriate temperature and will go into the auto clean cycle 5 Auto Clean The repot aut...

Страница 27: ...the repot 8 Be sure the hopper lid and glass door are both closed 1 At the starting screen press MENU Buttons U R A et at M E U U MENU Wall Control for Reference 6 Press DONE twice or wait 15 sec onds...

Страница 28: ...LEVEL to MEDIUM HIGH SETTING HEAT OUTPUT 1 Press and hold UP or DOWN but ton to set desired temperature 2 Press HOLD TEMP SETTING COMFORT LEVEL R A et at M E U U MENU NOTE Set temperature must be 3 d...

Страница 29: ...low the more frequent clean ing of the glass is required 4 Fire has tall ames with black tails and is lazy 4 The ame height adjustment needs to be reduced or the repot needs cleaning Heat exchanger or...

Страница 30: ...MB BLOWER JAMMED Combustion blower is blocked jammed Remove blockage Replace blower if necessary Must unplug the appliance to clear error AUGER JAMMED Auger jammed feed motor bad Pull the feed system...

Страница 31: ...in this section for each step listed in the chart below Cleaning or Inspection Frequency Daily Weekly Every 2 Weeks Monthly Yearly Ash Pan Burning Pellets Every 5 bags of fuel OR X Ash Pan Burning Alt...

Страница 32: ...ly depending on fuel type By Homeowner a The appliance must be in complete shutdown completely cool and the exhaust blower off b Inspect the auto clean springs for any degradation or deformation As th...

Страница 33: ...mplete shutdown completely cool and the exhaust blower off b It is necessary to remove the baf e to gain access to the heat exchanger Follow instructions for baf e removal on page 36 c Vacuum the ash...

Страница 34: ...on blower is mounted in the bottom right rear of the appliance Figure 34 1 2 Use an 11 32 nut driver to loosen all six nuts but do not remove Rotate the blower and remove from the housing Figure 34 2...

Страница 35: ...Burn Season Frequency At the end of heating season By Homeowner a The appliance must be in complete shutdown completely cool and the exhaust blower offf b Remove all ash from the rebox and vacuum thor...

Страница 36: ...tion and push down and the bottom of the latch will fall forward off of post Locating ears 1 on each side Fit behind bottom edge Figure 36 2 WARNING Cast iron is a very heavy material The baf e is mad...

Страница 37: ...37 1 a Swing open the face and remove door from the appli ance by lifting door off of hinge pins and lay on a at surface face down b Using a Phillips head screw driver remove 4 screws 2 on the top and...

Страница 38: ...commended to protect the electronics When describing the location of a component it is always AS YOU FACE THE FRONT OF THE APPLIANCE 5 Convection Blower The convection blower is mounted at the bottom...

Страница 39: ...ted on the right side of the appliance under the feed motor behind the right side panel and connects to the drop tube with a hose This switch turns the feed system on when vacuum is present in the reb...

Страница 40: ...wer Figure 40 3 Heat Exchanger Baffle Ash Pan Firepot Thermocouple Thermocouple Cover Baffle Firepot Ash Pan Thermocouple and Thermocouple Cover Heat Exchanger Front Back Power Supply Control Board Co...

Страница 41: ...niter SRV7000 226 17 Thermocouple SRV7000 334 18 Clip Half 7000 321 19 Thermocouple Cover SRV7034 186 20 Firepot Assembly SRV7034 010 21 Gasket Firepot 7034 190 22 Auto Clean Motor Arm Assy 7034 020 2...

Страница 42: ...DC Current 68 Glass Side with Gasket 40 Gasket Ash Door 55 Switch Optical Assembly 69 Gasket Rope Door 41 Bottom Base 56 Bracket Feed Motor 70 Hinge Male Door 42 Bracket Latch Assembly 57 Gasket Feed...

Страница 43: ...TR CAST CSB Trim Cast Set Powder Coat Willow TR CAST CWL Trim Cast Set Porcelain Mahogany 811 0960 Item No Service Parts Part No 39 Ash Pan Assembly 7034 013 77 Ash Pan Door 7034 133 Auto Clean Botto...

Страница 44: ...Assembly 7034 006 1 Door Frame Assembly 7034 026 7 Door Air De ector 7034 185 75 Door Left Matte Black 7005 110MBK 75 Door Left Porcelain Mahogany 7005 110PMH 75 Door Left Powder Coat Sienna Bronze 7...

Страница 45: ...10 60 Hinge Assembly Top 7036 006 5 Hinge Female Door 450 2910 70 Hinge Male Door 7034 138 73 Hinge Pin Retainer Front Door 7036 112 74 Hinge Pin Front 4 inches Door 7036 110 61 Hopper Lid Matte Black...

Страница 46: ...ft right are interchangeable 7036 103CWL 13 Spring Auto Clean Qty 4 7000 299 4 43 Switch Magnetic 7000 375 30 Switch Micro Normally Open 7000 327 55 Switch Optical Assembly 7034 038 17 Thermocouple Fi...

Страница 47: ...R September 1 2008 7036 135E Page 47 Mt Vernon Pellet Insert AE Date of Service Performed By Description of Service E Service And Maintenance Log...

Страница 48: ...Page 48 7036 135E September 1 2008 R Mt Vernon Pellet Insert AE Date of Service Performed By Description of Service E Service And Maintenance Log Cont d...

Страница 49: ...R September 1 2008 7036 135E Page 49 Mt Vernon Pellet Insert AE F Homeowner s Notes...

Страница 50: ...ee Conditions Exclusions and limitations 9 01 08 CONDITIONS EXCLUSIONS LIMITATION OF LIABILITY This warranty applies to the original owner and is transferable up to two years from date of purchase to...

Страница 51: ...chlorine uorine or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation or there is any damage to the appliance or other components due to water or weathe...

Страница 52: ...6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6863064 686...