MT VERNON-AE TROUBLE SHOOTING MANUAL
7020-057D
9-30-2010
OPERATIONAL SYMPTOMS
UNIT HAS NO POWER OR LOSES POWER AFTER 15 TO 20 MINUTES:
SEE PAGE 20
(POWER
SUPPLY TROUBLE-SHOOTING)
UNIT IS MAKING A RUMBLING NOISE DURING START-UP:
CHECK THE FUEL SETTINGS AND
MAKE SURE THE UNIT IS CLEAN.
SEE PAGE 12
(FIREBOX VACUUM TESTING)
UNIT IS BUILDING UP BLACK SOOT ON THE GLASS:
CHECK THE FUEL SETTINGS AND
MAKE SURE THE UNIT IS CLEAN.
SEE PAGE 12
(FIREBOX VACUUM TESTING)
IGNITER IS NOT GETTING HOT: SEE PAGE 19
(IGNITER TROUBLE-SHOOTING). ENSURE THE
IGNITER CHAMBER UPDATE HAS BEEN DONE. REFERENCE THE SEPT. 18, 2007 FIELD COM-
MUNICATION.
UNIT LIGHTS AND GOES OUT DURING START-UP: SEE PAGE 16
(FIREPOT THERMOCOUPLE
TROUBLE-SHOOTING)
UNIT WILL NOT LIGHT & BURN CORN CONSISTENTLY:
CHECK FUEL SETTINGS. CORN
MUST BE SCREENED.
SEE PAGE 14
(FIREPOT & AUTOCLEAN TROUBLE-SHOOTING)
WALL CONTROL SCREEN IS SHUTTING OFF: SEE PAGE 22
(WALL CONTROL TESTING)
PAGE 9
Содержание MT VERNON-AE
Страница 16: ...MT VERNON AE TROUBLE SHOOTING MANUAL 7020 057D 9 30 2010 PAGE 16 FIREPOT THERMOCOUPLE TROUBLE SHOOTING ...
Страница 17: ...MT VERNON AE TROUBLE SHOOTING MANUAL 7020 057D 9 30 2010 FIREPOT THERMOCOUPLE TROUBLE SHOOTING PAGE 17 ...
Страница 18: ...MT VERNON AE TROUBLE SHOOTING MANUAL 7020 057D 9 30 2010 FIREPOT THERMOCOUPLE TROUBLE SHOOTING PAGE 18 ...
Страница 29: ...MT VERNON AE TROUBLE SHOOTING MANUAL 7020 057D 9 30 2010 ...