August 3, 2015
7033-277N
Page 11
3100 Wood Stove Series (ACC)
R
B. Clearances to Combustibles (UL and ULC)
BACKWALL / SIDEWALL
A
B
C
D
E
F
F
E
CORNER INSTALLATION
C
ALCOVE TOP VIEW
G
A
ALCOVE SIDE VIEW
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
Fire Risk.
• Comply with all minimum clearances to
combustibles as specifi ed.
• Failure to comply may cause house fi re.
WARNING
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 19 inches (483mm) is required on the right side of stove in
order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment.
G
H*
STOVE TO
CEILING
CLEARANCE
14-1/8
(359mm)
20-7/8 (531mm)
A
In USA and Canada wood is
permitted to be stored in the
pedestal if the wood does not
extend past the face (A) of the
storage area.
NOTE: A, C and F measurements
are to center of fl ue
A
B
C
D
E
F
G
H
INSTALLATION: Full Vertical or Horizontal with Vertical Rise
SINGLE WALL PIPE
- A, B, C and D dimensions are based off of standard 18” stove pipe clearances to combustibles or unit certifi ed clearances,
whichever is greater
Millennium/Limited Edition
18-1/4 [464]
11-3/4 [298]
28-1/2 [724]
16 [406]
8 [203]
20 [508]
48 [1219]
12 [305]
Step Top
15 [381]
8-1/2 [216]
25 [635]
12-1/2 [318]
5-1/2 [140]
17-1/2 [445]
48 [1219]
12 [305]
DOUBLE WALL PIPE
- A, B, C and D dimensions are based off of certifi cation clearances. Stove pipe manufacture clearances MUSt be adhered to if
they exceed certifi ed unit clearances.
Millennium/Limited Edition
13-1/2 [343]
6-1/2 [165]
25 [635]
13 [330]
6-1/2 [165]
18-1/2 [470]
48 [1219]
9 [229]
Step Top
13 [330]
6 [152]
23-1/2 [597]
11 [279]
4 [102]
16 [406]
48 [1219]
9 [229]
INSTALLATION - 90
°
Elbow off top of stove through backwall
SINGLE WALL PIPE
Millennium/Limited Edition
15 [381]
8-1/2 [216]
25 [635]
13 [330]
8 [203]
20 [508]
48 [1219]
12 [305]
Step Top
13 [330]
6 [152]
23-1/2 [597]
11 [279]
5-1/2 [140]
17-1/2 [445]
48 [1219]
12 [305]
DOUBLE WALL PIPE
Millennium/Limited Edition
11 [279]
4-1/2 [114]
20-1/2 [521]
8-1/2 [216]
6-1/2 [165]
18-1/2 [470]
48 [1219]
9 [229]
Step Top
13 [330]
6 [152]
23-1/2 [597]
11 [279]
4 [102]
16 [406]
48 [1219]
9 [229]
INSTALLATION: ALCOVE - Six inch (6”) [152] diameter listed DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built Class “A”
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48” [1220]
with a minimum height of 48” [1092] to top of unit, and the referenced clearances. Canada must comply with CAN/ULC-S269 M87 for the 650
°
factory
built chimney
DOUBLE WALL PIPE
Millennium/Limited Edition
14-3/4 [375]
8-1/4 [210]
26-1/2 [673]
14-1/2 [368]
N/A
N/A
48 [1219]
N/A
Step Top
13 [330]
6 [152]
23-1/2 [597]
11 [279]
N/A
N/A
48 [1219]
N/A
G
H
STOVE TO
CEILING
CLEARANCE
*
* If H = N/A, follow Pipe Manu-
facturer’s clearances