background image

15

Quadra-Fire  •  GARN-MBK-IPI, GARN-D-PMH-IPI, GARN-D-MBK-IPI, GARN-D-CSB-IPI Owner’s Manual  •  2345-981  •  5/14

C.  Maintenance Tasks - Quali

fi

 ed Service 

Technician

The

 

following tasks must be performed by a quali

fi

 ed ser-

vice technician.

Gasket Seal and Glass Assembly Inspection

Frequency: 

Annually

By:  

Quali

fi

 ed Service Technician

Tools needed:

 Protective gloves, drop cloth and a stable 

work surface.
•  Inspect gasket seal and its condition.
• Inspect 

fi

 xed glass assembly for scratches and nicks that 

can lead to breakage when exposed to heat. 

• Con

fi

 rm there is no damage to glass or glass frame. 

Replace as necessary.

• Verify that 

fi

 xed glass assembly is properly retained and 

attachment components are intact and not damaged. 
Replace as necessary. 

Logs

Frequency: 

Annually

By:  

Quali

fi

 ed Service Technician

Tools needed:

 Protective gloves.

•  Inspect for damaged or missing logs.  Replace as neces-

sary.  Refer to Installation Manual for log placement instruc-
tions.

•  Verify correct log placement and no 

fl

 ame impingement 

causing sooting.  Correct as necessary.

Firebox

Frequency: 

Annually

By:  

Quali

fi

 ed Service Technician

Tools needed:

 Protective gloves, sandpaper, steel wool, 

cloths, mineral spirits, primer and touch-up paint.
•  Inspect for paint condition, warped surfaces, corrosion 

or perforation.  Sand and repaint as necessary.

• Replace 

fi

 replace if 

fi

 rebox has been perforated. 

Control Compartment and Firebox Top

Frequency: 

Annually

By:  

Quali

fi

 ed Service Technician

Tools needed:

 Protective gloves, vacuum cleaner, dust 

cloths
•  Vacuum and wipe out dust, cobwebs, debris or pet hair.  

Use caution when cleaning these areas.  Screw tips that 
have penetrated the sheet metal are sharp and should 
be avoided.

•  Remove all foreign objects.
•  Verify unobstructed air circulation.

Burner Ignition and Operation

Frequency: 

Annually

By:  

Quali

fi

 ed Service Technician

Tools needed:

 Protective gloves, vacuum cleaner, whisk 

broom, 

fl

 ashlight, voltmeter, indexed drill bit set, and a 

manometer.
•  Verify burner is properly secured and aligned with pilot 

or igniter.

•  Clean off burner top, inspect for plugged ports, corrosion 

or deterioration.  Replace burner if necessary.

•  Replace Glowing embers with new dime-size pieces.  

DO NOT

 block ports or obstruct lighting paths. Refer to 

Installation Manual for proper ember placement.

•  Verify batteries have been removed from battery back-

up IPI systems to prevent premature battery failure or 
leaking.

•  Check for smooth lighting and ignition carryover to all 

ports. Verify that there is no ignition delay.

•  Inspect for lifting or other 

fl

 ame problems.

•  Verify air shutter setting is correct.  See Installation 

Manual for required air shutter setting.  Verify air shutter 
is clear of dust and debris. 

• Inspect ori

fi

 ce for soot, dirt and corrosion. Verify ori

fi

 ce 

size is correct.  See Service Parts List  for proper ori

fi

 ce 

sizing.

•  Verify manifold and inlet pressures. Adjust regulator as 

required.

• Inspect pilot 

fl

 ame pattern and strength. See Figure 4.3 

for proper pilot 

fl

 ame pattern. Clean or replace ori

fi

 ce 

spud as necessary.

• Inspect

 

IPI 

fl

 ame sensing rod for soot, corrosion and 

deterioration. Polish with 

fi

 ne steel wool or replace as 

required.

•  Verify that there is not a short in 

fl

 ame sense circuit 

by checking continuity between pilot hood and 

fl

 ame 

sensing rod. Replace pilot as necessary.

Figure 4.3  IPI Pilot Flame Patterns

Содержание GARN-D-CSB-IPI

Страница 1: ...nts for location of additional Commonwealth of Massachusetts requirements DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to do i...

Страница 2: ...liance information below Dealer Name ________________________________________________________ Address ____________________________________________________________ _____________________________________...

Страница 3: ...mation A Appliance Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specific...

Страница 4: ...on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independ...

Страница 5: ...HE EXPRESSED WARRANTY SPECIFIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color...

Страница 6: ...est edition in the U S A and the CAN CGA B149 Installation Codes in Canada 2 2 Product Specific Information B Glass Specifications Ceramic This appliance is equipped with 5 mm ceramic glass Re place g...

Страница 7: ...s of high temperatures High temperatures may ignite clothing or other flammable materials Clothing furniture draperies and other flammable materials must not be placed on or near the appliance Young c...

Страница 8: ...place WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed Figure 3 2 General Operating Parts B General Operating Parts C Fuel Specifications Figure 3 2 re...

Страница 9: ...on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 V...

Страница 10: ...circulation during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate G Heat Management Heat Output This model has a variable burn rate which is controll...

Страница 11: ...e control cavity of the appliance See Figure 3 5 for location 2 Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 3 A...

Страница 12: ...ch and the RC300 remote control to operate your fireplace the appliance switch will override any commands given by the remote 5 Module Reset This module may lock out under certain conditions When this...

Страница 13: ...To be completed by Glass Cleaning Seasonally Homeowner Remote Control Seasonally Venting Seasonally Gasket Seal and Glass Inspection Annually Qualified Service Technician Log Inspection Annually Fire...

Страница 14: ...eded in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your fireplace for an extended period of time summer months vacations trips etc to...

Страница 15: ...Use caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition an...

Страница 16: ...ng of the paint and the burning off of any oils remaining from manufacturing If appliance has not been used for some time dust can build up and cause an odor Film on the glass This is a normal result...

Страница 17: ...Check voltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than 4...

Страница 18: ...ensing rod to white sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms...

Страница 19: ...ildren See your dealer if you have questions Optional Fan If an optional fan is purchased have it installed by a qualified service technician Section 3 discusses using the fan to manage the heat outpu...

Страница 20: ...Parts R GARN MBK GARN D IPI Beginning Manufacturing Date June 2014 Ending Manufacturing Date Active Part number list on following page Log Set Assembly 3 1 2 Gas Stove DV 05 14 GARNET D CSB GARNET MB...

Страница 21: ...Coat Black 7016 109MBK Sienna Bronze 7016 109CSB Mahogany 7016 109PMH 6 Grommet 2118 420 7 Pilot Shield 2344 103 8 Pilot Assembly 2090 012 Y 9 Burner Assembly 2344 007 Y 10 Door Assembly GLA 2344 019...

Страница 22: ...ly to consumers Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 27 1 Blower Shroud Top 2344...

Страница 23: ...g service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 18 1 Battery Pack 2166 323 18 2 Junction Box 4021 013 Y 18 3 Transformer 2326 131 Y 18 4 Componen...

Страница 24: ...__________________________________________________________ ________________________________________________________________________________ ____________________________________________________________...

Отзывы: