 2 

 

 

 

 

                         7060-227D 

 

 

 

         February 25, 2016

Explorer III Wood Stove

B. Sample of Serial Number / Safety Label 

LOCATION:  Back of unit

room for .14 x .875” S/N

1.5” x .375 Barcode Label

SPÉCIFICATIONS DE LA VENTILATION:

MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de 
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en 
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, 
ou une cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit 
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe 
"A, ou une cheminée de briques, avec espaces libres alloués.

MAISON MOBILE:  PAS APPROUVÉ POUR MOBILE HOME INSTALLATIONS AU 
CANADA

MINIMUM CLEARANCES TO COMBUSTIBLES  In Inches & (Millimeters)

NOTE:  All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.

LISTED ROOM HEATER, SOLID FUEL TYPE.   
ALSO FOR USE IN MOBILE HOMES USA ONLY.  
(UM) 84 HUD .  

"For Use with Solid Wood Fuel 

Only" 

Install and use only in accordance with 
manufacturer's installation and operating 
instructions.  Contact local building or fire officials 
about restrictions and installation inspections in 
your area. Do not obstruct the space beneath 
heater.

WARNING - For Mobile Homes

:  Do not install in 

a sleeping room.  An outside combustion air inlet 
must be provided and unrestricted while unit is in 
use.  The structural integrity of the mobile home 
floor, ceiling and walls must be maintained.  The 
stove needs to be properly grounded to the frame 
of the mobile home.  Components required for 
mobile home installation:  Outside Air Kit, Part 
Number OAK-ACC. 

Refer to manufacturer's 

instructions

 and local codes for precautions 

required for passing chimney through a 
combustible wall or ceiling and maximum offsets.
Inspect and clean chimney frequently - Under 
Certain Conditions of Use, Creosote Buildup May 
Occur Rapidly. Do not connect this unit to a 
chimney serving another appliance. Optional 
Components:  Optional Blower, Part BK-ACC.
Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz. 
Route power cord away from unit.  Do not route 
cord under or in front of appliance.

DANGER: Risk 

of electrical shock.

  Disconnect power supply 

before servicing. Replace glass only with 5mm 
ceramic available from your dealer. Do not use 
grate or elevate fire.  Build wood fire directly on 
hearth. Do not overfire - if heater or chimney 
connector glows, you are overfiring. Operate only 
with the fuel loading door closed.  Open only to 
add fuel to the fire.

CAUTION

:

 

PREVENT HOUSE FIRES

   

Manufactured by:

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS

INSTALLATION: FULL VERTICAL AND ALCOVE/ Verticale complète et d'une alcôve 

 A 

 

SINGLE WALL PIPE

 

7.5 (191)  7.0 (178)  24.0 (610)  12.0 (305) 

7.0 (178)  15.0 (381)  52.5 (1334) 

NA  

NA 

NA 

CONDUIT DU MUR SIMPLE

DOUBLE WALL PIPE

 

6.5 (165)  6.0 (153)  24.0 (610)  12.0 (305) 

5.0 (127)  13.0 (330)  52.5 (1334) 

NA  

NA 

NA 

CONDUIT DU MUR DOUBLE

INSTALLATION:  90

ELBOW OFF TOP OF STOVE THROUGH BACKWALL

INSTALLATION:  90

DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE

DOUBLE WALL PIPE ONLY

   

6.5 (165)  6.0 (153)  24.0 (610)  12.0 (305) 

NA 

NA 

52.5 (1334)  27.0 (686) 

NA 

NA 

CONDUIT DU MUR DOUBLE

INSTALLATION:  HORIZONTAL THRU WALL
INSTALLATION:  HORIZONTALE AU MUR

SINGLE WALL PIPE

 

 

NA 

NA 

37.5 (953)  25.5 (648) 

NA 

NA 

52.5 (1334) 

NA             12.0 (305)    52.5 (1334) 

CONDUIT DU MUR SIMPLE

INSTALLATION: ALCOVE

 - Six inch (6 inches) (152mm) diameter listed SINGLE WALL or DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built Class "A" chimney, or a masonry 

chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm) with a minimum height of 84 inches (2133mm) from floor to bottom 
of ceiling, and the referenced clearances.

INSTALLATION: ALCÔVE 

De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour du mur simple au mur double avec une cheminée bâtit en usine 103HT de Classe "A", ou une cheminée de briques. (Les 

maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48 inches (1219mm) avec une hauteur minimum de 84 inches (2133mm) la distance entre du plancher et 
plafond inférieur, et des espaces libres alloués. 

VENT SPECIFICATIONS:

SINGLE WALL:

 Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or 

blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney, 
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.

DOUBLE WALL:

 Six inch (6 inches) (152mm) diameter, listed double wall air 

insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or  a 
masonry chimney and the referenced clearances

*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree 

Factory-built chimneys.

MOBILE HOME (USA ONLY):

  Use double wall pipe by Dura-Vent DVL, Selkirk 

Metalbestos DS or Security DL double wall connector pipe. Must be equipped with a 

spark arrestor.  Apply double wall clearances below when installing unit.

SERIAL NO.

 / NUMÉRO DE SÉRIE

EXPLORER III

 WOOD STOVE

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER
DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION

:

APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE 
COMBUSTIBLE SOLIDE, PAS APPROUVÉ POUR 
MOBILE HOME INSTALLATIONS AU CANADA"Pour 
Usage Avec Bois Solide Seulement"

Installez et utilisez en accord avec les instructions 
d'installation et d'opération du fabricant. Contactez le bureau 
de la construction ou le bureau des incendies au sujet des 
restrictions et des inspections d'installation dans votre 
voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
PAS APPROUVÉ POUR MOBILE HOME INSTALLATIONS 
AU CANADA! 
Référez vous aux instructions du fabricant et des codes 
locaux pour les précautions requises pour passer une 
cheminée à travers un mur ou un plafond combustibles, et les 
compensations maximums. Inspectez et nettoyez la 
cheminée fréquemment. Sous certaines conditions, il se peut 
que la créosote s'accumule rapidement.
Ne pas connecter cet appareil à une cheminée servant un 
autre appareil. Composants Optionnels: Ventilateur Optionnel, 
Pièce BK-ACC. Puissance Électrique: 115 VAC, 1.2 Amps, 60 
Hz. Éloignez le fil électrique de l'appareil. Ne pas faire passer 
le fil électrique au dessus ou en dessous de l'appareil. 
DANGER: Il y a risque de décharge électrique.  Déconnectez 
le fil électrique de la prise de contact avant le service. 
Remplacez la vitre seulement avec une vitre céramique de 5 
mm disponible chez votre fournisseur. N'élevez pas le feu. 
Bâtissez le feu de bois directement sur l'âtre. Ne pas 

surchauffer. Si l'appareil de chauffage ou le tuyau de 

cheminée rougissent, vous surchauffez. Opérez l'appareil 

seulement lorsque la porte de chargement est fermée. 

Ouvrez la porte seulement lorsque vous devez ajouter des 

combustibles dans le feu.

PRÉVENTION DES FEUX DE MAISON

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces & 

(millimètres)

NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de 

l'entrée du conduit.

BACKWALL/SIDEWALL

MUR ARRIÈRE/MUR DE CÔTÉ 

CORNER INSTALLATION
INSTALLATION DU COIN 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée 
bâtit en usine.

007063

TESTED TO:/ TESTÉ À:

   Conforms to UL Stds 1482-11 & 737-11

Certified to ULC Std S627-00

90  OFF TOP UP & 
OUT CEILING 
CLEARANCE
ESPACE LIBRE DU 
DESSUS DE 
L'APPAREIL 
AU PLAFOND AVEC 
90  
DE COURBURE 

Made in U.S.A. 

of US and imported parts.

Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées. 

1445 N. Highway, Colville, WA 99114

www.quadrafire.com

FLOOR PROTECTION:

In the USA floor protector must be Type II with an R 
value of 1.06 extending beneath heater and to 
front/sides/rear as indicated on the diagram. 

 

Exception: Non-combustible floor protections must 
extend beneath the flue pipe when installed with 
horizontal venting and extend 2 inches (51mm) 
beyond each side. 

16 in. from glass

8 in.

Fuel loading door

35-3/8

 in. min.

39-3/8 

in.min.

8 in.

203mm (8 in.)

203mm

(8 in.)

203mm

(8 in.)

457mm (18 in.)

1254

mm 

(

49-3/8

 in.)

minimum

1114mm (43-7/8

 in.)min.

D

C

A

B

E

F

H

G

B

J

I

MANTEL
12” MAX

HORIZONTAL THRU 
WALL
HORIZONTALE AU 
MUR

PROTECTION DU PLANCHER:

Au Canada protecteur de plancher doit être de type II avec 
et la valeur de R de 1,06 étendant sous chauffage et à 
l'avant / côtés / arrière, comme indiqué sur le schéma.
Exception: protections de plancher non combustibles 
doivent s'étendre au-dessous du conduit de fumée lorsqu'il 
est installé avec ventilation horizontale et étendre 2 pouces 
(51 mm) de chaque côté.

Owners Manual

Install Manual

O-T L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Report:

 

061-S-87-2

 

U.S. ENVIRONMENTAL PROTECTION AGENCY 

Certified to comply with 2015 particulate emission standards at 2.0 g/hr EPA Methods 28 and 5G. Not approved for sale after May 15, 2020.

This wood heater needs periodic inspection and repair for proper operation.  Consult the owner’s manual for further information.  It is against federal regulations 

to operate this wood heater in a manner inconsistent with the operating instructions in the owner’s manual.

2015

2016

2017

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEP

OCT

NOV

DEC

7060-239C

Serial No.

S

A

M

P

L

E

Test Lab & 
Report No.

Model 

Name

Mfg. Date

A. Congratulations

Hearth & Home Technologies welcomes you to our tradition 
of excellence!  In choosing a Quadra-Fire appliance, you 
have our assurance of commitment to quality, durability, and 
performance.

This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 

advanced technology to achieve the optimum opera-
tion of our stoves, inserts and fi replaces.  And yet we are 
old-fashioned when it comes to craftsmanship.  Each unit 
is meticulously fabricated and gold and nickel surfaces are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.      

We wish you and your family many years of enjoyment in the 
warmth and comfort of your hearth appliance. Thank you for 
choosing Quadra-Fire.

NOTE:  Clearances may only be reduced by means 

approved by the regulatory authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Содержание EXPLR-III-MBK

Страница 1: ...ies and other flammable materials away WARNING If the information in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warran...

Страница 2: ...EZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L ESPACE DÉSIGNÉ DE L INSTALLATION LE CONTACT PEUT CAUSER DES BRÛLURES À LAPEAU GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L ESPACE DÉSIGNÉ DE L APPAREIL VOIR L ÉTIQUETTE ET LES INSTRUCTIONS ATTENTION APPAREIL DE CHAUFFAGE DE PIÈCE DE TYPE DE COMBUSTIBLE SOLIDE PAS APPROUVÉ POUR MOBILE HOME INSTALLATIONS AU CANADA Pour Usage Avec Bois Solide Se...

Страница 3: ...BTU Efficiency Specifications 7 C Mobile Home Approved USA ONLY 7 D Glass Specifications 7 2 Operating Instructions 8 A Over Firing Your Appliance 8 B Wood Selection Storage 8 C Burning Process 8 D Automatic Combustion Control ACC 9 E Air Controls 9 F Burn Rates and Operating Efficiency 10 G Building A Fire 10 H Correct Baffle Blanket Placement 11 I Blower Operating Instructions 12 J Opacity Smoke...

Страница 4: ...onstruction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for co...

Страница 5: ...Explorer III Wood Stove WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _ q _ q _ q _ q _ q _ q _ q ...

Страница 6: ...OD 4 ADD KINDLING LIGHT THE PAPER 5 WARNING Risk of Fire Close and securely latch the door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the stove unattended with the door open Starting a fire may not require an open door for draft The air control should supply adequate draft 10 Piece...

Страница 7: ...s approved for mobile home installa tions in the USA when not installed in a sleeping room and when an outside combustion air inlet is provided The structural integrity of the mobile home floor ceil ing and walls must be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length...

Страница 8: ...rocess C Burning Process In recent years there has been an increasing concern about air quality Much of the blame for poor air quality has been placed on the burning of wood for home heating In order to improve the situation we at Quadra Fire have developed cleaner burning wood stoves that surpass the requirements for emissions established by our governing agencies These wood stoves like any other...

Страница 9: ...o learn how to operate your stove with ease E Air Controls 1 Burn Rate Air Control This air supply enters at the upper front of the firebox near the top of the glass door This preheated air supplies the necessary fresh oxygen to mix with the unburned gases helping to create second third and fourth combustions This air is regulated by the Burn RateAir Control When the control is moved all the way t...

Страница 10: ...aintain a continuous fire throughout the season F Burn Rates and Operating Efficiency This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal reg ulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual NOTE Due to altitude and other circumstances this operation info...

Страница 11: ...breaking or damaging the baffle boards DO NOT operate the stove without baffle boards Fire Risk Firebox damage due to improper baffle place ment is not covered by warranty Operate the wood burning appliance with the baffle in the cor rect position only Ensure correct baffle placement and replace baffle com ponents if damaged or missing Not doing so could result in Reduced efficiency Overheating th...

Страница 12: ...that no smoke column can be seen As you become familiar with your appliance you should periodically check the opacity This will allow you to know how to burn as nearly smoke free as possible goal of 0 opacity WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt drift wood May generate carbon monoxide if burn mate...

Страница 13: ... of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed WARNING Asphyxiation Risk Negative pressure can cause spillage of combustion fumes soot and carbon monoxide Appliance needs to draft properly fo...

Страница 14: ...f Wood WEEKLY or After Every 25 Loads of Wood Keep door and glass gasket in good shape to maintain good burn times on a low burn setting To test place a dollar bill between the stove and door and then shut the door If you can pull the dollar out remove one washer from door handle behind latch cam and try again If you can still pull it out replace the door gasket Check the glass frame for loose scr...

Страница 15: ...f creosote or soot has accumulated it should be removed to reduce the risk of a chimney fire B General Maintenance Fire Risk Do not use chimney cleaners or flame colorants in your appliance Will corrode chimney pipe WARNING WARNING Fire Risk Prevent creosote buildup Inspect chimney connector and chimney once every two months during heating season Remove creosote to reduce risk of chimney fire Igni...

Страница 16: ...will be flowing over the glass and the smokey relatively cool condition of a low fire will cause the glass to become coated Operating the appliance with the Burn Rate Air Control and Start UpAir Control all the way open for 30 45 minutes should remove the built up coating CAUTION Do not use polishes with abrasives It will scratch surfaces Fire Risk Disposal of Ashes WARNING Ashes should be placed ...

Страница 17: ...nt height refer to Chimney Height Section Refer to Negative Pressure section Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire Section Flue blockage such as birds nests or leaves in termination cap Have chimney inspected for creosote an...

Страница 18: ...h retainer alternately a few turns at a time until the glass is secure DO NOT OVERTIGHTEN 9 Replace the door on the appliance Quadra Fire stoves are equipped with ceramic super heat resistant glass which can only be broken by impact or misuse Do not slam stove door or impact the glass When closing door make sure that logs do not protrude against the glass Inspect glass regularly If you find a crac...

Страница 19: ...p disc and spade connectors back inside bracket Reassemble in reverse order E Secondary Tube Baffle Board Removal Be sure to soak with penetrating oil for 15 to 20 minutes before trying to remove the bolts Remove the 6 bolts 3 of which are shown in Figure 19 3 from bottom of baffle as sembly as shown using 5 32 allen wrench Figure 19 2 Magnet Spade Connectors Snap Disc D Door Handle Assembly 1 Sli...

Страница 20: ...20 7060 227D February 25 2016 Explorer III Wood Stove ...

Страница 21: ...February 25 2016 7060 227D 21 Explorer III Wood Stove Date of Service Performed By Description of Service A Service Maintenance Log 6 Reference Materials ...

Страница 22: ...lor SKU Mfg Dates Matte Black EXPLR III MBK 02 15 Porcelain Black EXPLR III PBK 02 15 Porcelain Dark Blue EXPLR III PDB 02 15 Porcelain Frost EXPLR III PFT 02 15 Porcelain Mahogany EXPLR III PMH 02 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 28 27 30 29 31 32 33 34 35 36 22 Part number list on following page 02 16 B Service Parts Accessories ...

Страница 23: ...H Porcelain Dark Blue 7060 101PDB Porcelain Black 7060 101PBK Porcelain Frost 7060 101PFT 9 Side Left Matte Black 7060 034MBK Porcelain Mahogany 7060 034PMH Porcelain Dark Blue 7060 034PDB Porcelain Black 7060 034PBK Porcelain Frost 7060 034PFT 10 Rear Brick Retainer SRV7060 133 11 Side Brick Retainer Qty 2 req SRV7060 193 12 Brick Assembly SRV7060 017 13 Ashlip Matte Black 7060 113MBK Porcelain M...

Страница 24: ...1141 14 9 Nut 2Wy Side Lock Jam 3 Pkg of 24 226 0100 24 Y 14 10 Key Cam Latch 430 1151 15 Front Matte Black 7060 103MBK Porcelain Mahogany 7060 103PMH Porcelain Dark Blue 7060 103PDB Porcelain Black 7060 103PBK Porcelain Frost 7060 103PFT 16 Andirons 2 pcs SRV7061 020 17 Front Air Channel SRV7060 132 18 ARS Channel SRV7061 184 19 ARS Access Cover SRV7038 196 20 ARS Latch Assembly SRV7060 050 21 Bu...

Страница 25: ...036 Timer Only Replacement Assembly SRV480 1940 Y 29 Secondary Channels Qty 2 req SRV7060 208 30 BafÀe Assembly SRV7060 025 30 1 BafÀe Cover Top Includes Insulation Blanket SRV7060 238 30 2 BafÀe Blanket SRV7060 233 Y 30 3 BafÀe Plate SRV7060 250 30 4 BafÀe Board SRV7060 148 Y 30 5 Secondary Tubes Qty 3 req SRV7060 226 Y 30 6 BafÀe Cover Plates SRV7060 206 30 7 BafÀe Linkage SRV7060 044 31 Side Ri...

Страница 26: ...t Touch Up Matte Black 812 0910 Porcelain Mahogany 855 1450 Porcelain Dark Blue 1 00 0020 Porcelain Black 1 00 0022 Porcelain Frost 1 00 0021 ACCESSORIES Blower Assembly BK ACC Blower Control Box W Switch SRV7000 194 Y Component Pack 7033 051 Magnet Round SRV7000 140 Y Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Speed Control Only Rheostat 842 0370 Y Wire Harnes...

Страница 27: ...February 25 2016 7060 227D 27 Explorer III Wood Stove ...

Страница 28: ...peration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following pe...

Отзывы: