Quadra-Fire Direct Vent Gas Appliance COLBAY-FS-B Скачать руководство пользователя страница 26

Page  26

10/08

Quadra-Fire  •  Columbia Bay  •  250-5195 Rev. K

7

Electrical Information

A.  Recommendation for Wire

C.  Standing Pilot Ignition System Wiring

See B5 below for recommended maximum lead length (two 
wire) when using wall thermostat/switch.

B. Connecting to the Appliance

This appliance 

DOES NOT

 require 110 VAC supply for 

operation. A wiring diagram is shown in 

Figure 7.1 

on the 

next page.

This appliance is equipped with a millivolt control valve.

NOTE:

  This appliance must be electrically wired and 

grounded in accordance with local codes or, in the absence 
of local codes, with 

National Electric Code ANSI/NFPA 

70-latest edition

 or the 

Canadian Electric Code, CSA 

C221.1.

Do not connect this appliance to a thermostat serving 
any other appliance.  

Bedroom installation in Canada requires this appliance 
to be connected to a thermostat.

1.  This appliance may be used with a wall switch, wall 

mounted thermostat and / or a remote control.

2. 

If using thermostat, use one compatible with a millivolt 
gas valve system.

3. 

Follow parameters for locating thermostat (see individ-
ual thermostat instructions) to ensure proper operation 
of appliance.

4. 

Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.

5. 

Use the following chart for wire sizing.

6.  Keep wire lengths as short as possible by removing 

any excess wire length.

7. 

Low voltage and 110 VAC voltage cannot be shared 
within the same wall box.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

WARNING

Shock hazard.
•   This appliance is equipped with a three 

This appliance is equipped with a three 
pronged (grounding) plug for your protection 

pronged (grounding) plug for your protection 
against shock hazard and should be plugged 

against shock hazard and should be plugged 
directly into a prop

directly into a properly grounded three prong 
receptacle. Do not cut or remove the grounding 
prong from this plug.

WARNING

Wire 110v to electrical junction box. 
Do NOT wire 110v to the valve.
Do NOT wire 110V to wall switch.
•  Incorrect wiring will damage millivolt 

systems.

8.  Ensure the thermostat is mounted level for accurate 

readings.

9. 

The thermostat should be mounted on an inside wall 
and not in direct line with the appliance convection air.

10.  If the thermostat is located too close to the appliance, 

you may need to set the temperature setting slightly 
higher to maintain the desired temperature in your 
home.

•  A 110-120 VAC circuit for this product must be protected 

with ground-fault circuit-interrupter protection, in 
compliance with the applicable electrical codes, when 
it is installed in locations such as in bathrooms or near 
sinks.

Содержание Direct Vent Gas Appliance COLBAY-FS-B

Страница 1: ...stalledasanOEM installation in manufactured home USAonly or mobile home and must be installed in accordance with the manufacturer s instructions and the manufactured home con struction and safety stan...

Страница 2: ...1 02 Le canada tuyau minimum 65 42 NG 65 96 LP APPROUV POUR LE CANADA ET LES TATS UNIS ANSI Z21 88a 2001 CSA 2 33a M01 Fournaises au Gaz avec Ventilation et les sections applicable de UL 307b Appareil...

Страница 3: ...rtical Termination 15 Section 6 Gas Information A Fuel Conversions 22 B Gas Pressures 24 C Gas Connection 24 Section 7 Electrical Information A Recommendation for Wire 26 B Connecting to the Appliance...

Страница 4: ...nput BTU Minimum Input BTU Orifice Size DMS Efficiency Up To P 4 Columbia Bay FS NG 30 000 21 000 36 84 65 42 Columbia Bay FS LP 30 000 24 500 52 86 65 96 Manufactured Home or Mobile Home installation...

Страница 5: ...ust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF A...

Страница 6: ...ro tective surface Remove log set and component pack from firebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starti...

Страница 7: ...RNING B Clearances Figure 3 1 Model A A B C D E F G H I Columbia Bay FS Inches 6 6 3 4 2 6 14 2 84 19 36 36 Millimeters 152 171 515 152 356 51 2134 483 914 914 NOTE Flooring beneath appliance may reac...

Страница 8: ...DISCHARGE OPENING 2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H Min Ft Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12...

Страница 9: ...___________________________________________ _ _ QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMA...

Страница 10: ...flue WARNING Diagonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45...

Страница 11: ...l dimension from the center line of the flue vent to the center of the 90 elbow is 7 ft 2m the horizontal run to the outer wall flange must not exceed 13 ft 4m EXAMPLE 2 If the vertical dimension from...

Страница 12: ...s per installation instructions Connect vent sections per installation instructions Maintain all clearances to combustibles Do NOT allow vent to sag below connection point to appliance Maintain specif...

Страница 13: ...c around its outside edges so as to make a seal between it and the wall attach termination cap to the exterior wall with the four wood screws provided The arrow on the vent cap should be pointing up F...

Страница 14: ...on cap must be sealed with silicone Termination caps shall not be recessed into a wall or siding Fire Risk Explosion Risk Maintain vent clearance to combustibles as specified WARNING Do not pack air s...

Страница 15: ...TIONAL RESTRICTION This installation may not have two horizontal sections connected by 90 elbows Figure 5 12 Step 1 Check the installation instructions for required 1 in 25mm clearances air space to c...

Страница 16: ...e and elbow connections are in their fully twist locked position Assemble as instructed NOTE 1 If an offset is necessary in the attic to avoid obstructions it is important to support the vent pipe eve...

Страница 17: ...ween the storm collar and the pipe OPTIONAL HIGH WIND TERMINATION CAP SECURE FLASHING WITH NON HARDENING SEALANT AND ROOFING NAILS Figure 5 16 MIN 1 in 25mm CLEARANCE CEILING FIRESTOP NAILS MIN 1 in 2...

Страница 18: ...he top edges of the support box to make a seal between it and the roof Clean out any combustible material from inside the support box Step 7 Complete the cathedral ceiling installation by following th...

Страница 19: ...8 in 3mm diameter holes through the top adapter and into the chimney top Ensure that you are drilling into the metal on the chimney Twist lock the high wind termination cap onto the top adapter Figure...

Страница 20: ...framed a wall thimble is required This allows the retro connector to mount directly on the masonry and provide the correct clearances to combustibles Figure 5 26 Step 3 Secure the flashing to the top...

Страница 21: ...that the connector is centered in the opening and the mounting holes line up with the masonry wall Step 8 Secure the top adapter to the flashing Use three sheet metal screws through the side of the t...

Страница 22: ...t pilot injector valve regulator conversion label TOOLS REQUIRED Power drill a 90 handle is helpful 2 Phillips bit 5 32 in Allen wrench 5 8 in open end wrench If the shutter is removed with the burner...

Страница 23: ...actly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of th...

Страница 24: ...sachusetts approved 1 2 inch 13mm T handle manual shut off valve and flexible gas connector are connected to the 1 2 inch 13mm control valve inlet If substituting for these components please consult l...

Страница 25: ...and connections Do not use open flame After the gas line installation is complete all connections must be tightened and checked for leaks with a commercially available non corrosive leak check soluti...

Страница 26: ...mostat 5 Use the following chart for wire sizing 6 Keep wire lengths as short as possible by removing any excess wire length 7 Low voltage and 110 VAC voltage cannot be shared within the same wall box...

Страница 27: ...can cause improper and dangerous operation Verify proper operation after servicing Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperature insulation CAUTION Red...

Страница 28: ...sed safely WARNING C Door Crown Installation IMPORTANT PREVENT PERMANENT STAINING 2 Screws 2 Screws Use a soft cloth and a window cleaning solution to clean all fingerprint oils from the gold or nicke...

Страница 29: ...e appliance E Positioning the Logs While still breakable the logs do not become fragile until after the appliance is burned and they have cured After curing any handling must be done with care as brea...

Страница 30: ...ove the existing door from the appliance Remove the crown from the existing door by removing four screws on the back side of the door assembly Pull crown off door face Install replacement door with gl...

Страница 31: ...lower housing to appliance Turn power supply back on Blower motor comes standard with 2 male spade wire connectors If your appliance has a different connec tion use the two female spade wire connector...

Страница 32: ...lame Improper adjustment can cause sooting in the firebox and or on the outside of a house with a horizontal termination After adjustment tighten nut to lock in place I Vertical Damper Adjustment Figu...

Страница 33: ...that there are no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the flow of combustion and ventilation air is not obstructed front grilles and vent caps B Controls...

Страница 34: ...t the power from the appliance 4 Open the door of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five...

Страница 35: ...detectors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if ap...

Страница 36: ...he thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocoup...

Страница 37: ...ing exhaust gases back into the system Check for proper vent connection at flue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to...

Страница 38: ...tching or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Do NOT clean glass when hot Turn off appliance after 3 4 hours of operation and ALLOW TO COOL...

Страница 39: ...t as neces sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect fo...

Страница 40: ...Page 40 10 08 Quadra Fire Columbia Bay 250 5195 Rev K B Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 41: ...ctual appliance dimensions Use for reference only For clearances refer to Section 3 Figure 12 1 Appliance Dimensions A B F G H I J K C D E Location Inches Millimeter Location Inches Millimeter A 22 1...

Страница 42: ...in 184 mm 7 1 4 in 184 mm 5 1 4 in 133 mm 25 1 4 in 641 mm 37 1 4 in 946 mm 49 1 4 in 1251 mm 13 1 4 in 337 mm 13 1 4 in 337 mm 6 5 8 in 168 mm 6 5 8 in 168 mm 6 5 8 in 168 mm 6 5 8 in 168 mm SLP45 SL...

Страница 43: ...iling Firestop SLP WS Wall Firestop SLP HVS Pipe Support Hanger 950 Vinyl Protector Kit SL Pipe DRC RADIUS Decorative Radius Cover HTI DV WT Wall Thimble RF4 8 Roof Flashing TERMINATION KITS SLP TRAP2...

Страница 44: ...250 5195 Rev K Service Parts Diagram Part number list on following page Log Set Assembly COLBAY FS B Columbia Bay Free Standing 1 2 3 4 5 6 7 8 9 R D Service Parts List Beginning Manufacturing Date Fe...

Страница 45: ...alve Cover 474 0240 Adaptor Inner 4 200 2470 Adaptor 6 5 8 7000 162 Baffle Assembly 842 4051 Baffle Hanger 452 0030 Brick Refractory Ceramic 841 0810 Burner Pan 474 0080 Burner Support Kit 842 5190 El...

Страница 46: ...30 0730 Y 3 Piezo Ignitor 291 513 Y 4 Knob On Off 571 534 Y 5 Knob Hi Lo 571 533 Y 6 Valve NG 842 0240 Y Valve LP 842 0230 Y Valve Bracket 474 0230 7 Latch Assembly 452 5070 Y 8 Blower 812 4900 Y Blow...

Страница 47: ...able under this warranty is limited to the purchase price of the product In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product Adjustments regula...

Страница 48: ...zed and approved by HHT in writing This warranty does not apply to non HHT venting components hearth components or other accessories used in conjunction with the installation of this product This warr...

Страница 49: ...___________ Columbia Bay Direct Vent Gas Appliance Do NOT discard this manual CAUTION Important operating and maintenance instructions included Read understand and follow these instruc tions for safe...