background image

 28 

 

 

 

 

                       7014-258B 

 

 

 

     November 30, 2017

CONTACT INFORMATION 

Hearth & Home Technologies

352 Mountain House Road

Halifax, PA  17032

Division of HNI INDUSTRIES

Please contact your Quadra-Fire dealer with any questions or concerns. 

For the number of your nearest Quadra-Fire dealer

log onto www.quadrafire.com

DO NOT DISCARD THIS MANUAL

CAUTION

•  Important operating and 

maintenance  instruc-

tions included.

• 

Leave this manual with 

party responsible for use 

and operation.

• 

Read, understand and 

follow  these  instruc-

tions for safe installa-

tion and operation.

DO NOT

DISCARD

We recommend that you record the following pertinent

 information for your heating appliance.

Date purchased/installed:_________________________________________________________________________

Serial Number:____________________________________ Location on appliance:___________________________

Dealership purchased from:________________________________________ Dealer phone:_1(_____)_____-______

Notes:________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962 

or other U.S. and foreign patents pending.

Содержание CB1200M-MBK

Страница 1: ...allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing...

Страница 2: ...4 B Thermostat Wall Control Location 5 C Tools And Supplies Needed 5 D Inspect Appliance and Components 5 E Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearances to...

Страница 3: ...without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Risk Hearth Hom...

Страница 4: ...the installation Location of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to mini...

Страница 5: ...s location will have some affect on the appliance s operation Maximum wire length from appliance is 100 feet 30 48m continuous non spliced wire Recommended 20 gauge wire solid copper When located clo...

Страница 6: ...ation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the a...

Страница 7: ...ESTANDING Figure 7 1 Top View Figure 7 2 Side View Figure 7 3 Front View 6 1 4 159 8 203 8 203 25 3 4 654 27 5 8 702 8 204 25 3 4 654 28 1 2 724 31 5 8 803 28 1 2 725 21 1 4 539 10 3 8 264 3 Dimension...

Страница 8: ...62 33 1 8 841 31 1 4 795 Figure 8 1 Top View with Top Vent Adapter TPVNT 1 and Offset Adapter 812 3570 Figure 8 2 Side View with Top Vent Adapter TPVNT 1 and Offset Adapter 812 3570 Figure 8 3 Top Vie...

Страница 9: ...REESTANDING 2 3 8 62 2 3 4 69 3 7 8 100 6 1 4 159 8 203 8 203 15 51 8 398 14 357 Figure 9 1 Top View with Top Vent Adapter TPVNT 6 and Offset Adapter 811 0720 Figure 9 2 Side View with Top Vent Adapte...

Страница 10: ...ack Wall to Appliance 7 5 191 Corner Installation Inches Millimeters G Side Wall to Flue Pipe 2 51 Installations with TPVNT 1 Top Vent Adapter with Heat Shield and Clean out TPVNT 6 Top Vent Adapter w...

Страница 11: ...pipe shaded area to the wall thimble CANADA 47 3 4 in 26 1 4 in 21 1 2 in 41 3 8 in 6 in from the fuel door opening USA 1214mm 666mm 545mm 1051mm 152mm front door opening CANADA Must extend 51mm beyo...

Страница 12: ...strations diagrams are not drawn to scale Actual installation may vary due to individual design preference D Alcove Figure 12 1 All minimums listed are to a combustible surface Figure 12 2 Minimum Max...

Страница 13: ...lk paved driveway located on public property M 12 in Under an open veranda porch deck or balcony N See Note below Electric service above below or to the side location must not obstruct or interfere wi...

Страница 14: ...t of the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be necessary to add additional vent...

Страница 15: ...mm diameter type L or PL venting system It can be vented vertically or horizontally 2 Mobile Home Approved for all Listed pellet vent If using the 3 inch 76mm vertical Top Vent Adapter Kit or the 3 to...

Страница 16: ...F FEET 0 20 30 1 2 3 4 5 6 7 8 9 10 4 in 102mm Diameter Pipe Only 10 Example 1 Example 2 Example 1 If the equivalent length of pipe is 23 feet 7m with altitude of 8 000 feet 2438m you must use 4 inch...

Страница 17: ...d for mobile home installa tions Must use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage t...

Страница 18: ...g Rain Cap 6 in 152mm Min Non combustible Hearth Pad 3 in 76mm Min 24 in 610mm Minimum 3 in to 3 in 76 76mm Top Vent Kit Clean out Cover All three installations are approved for mobile home installa t...

Страница 19: ...pace Concrete Cap 1 in 25mm Clearance with Firestop 6 in 152mm Minimum Non Combustible Hearth Pad Sheathing 2 in 51mm Minimum 1 in 25mm Clearance Flashing Fireclay Flue Liner withAirspace Concrete Cap...

Страница 20: ...utside termination cap with second hose clamp e Secure termination cap to outside surface f Secure trim ring to interior wall g Snip corners and remove plate Figure 20 1 h Align and secure collar asse...

Страница 21: ...ppliance using the outer shield as a pattern make sure the assembly is vertical Figure 21 1 4 Install the 4 mounting screws 5 Install the vent pipe into the top vent adapter be sure to silicone all jo...

Страница 22: ...2 studs into the already drilled holes See Figure 22 4 Figure 22 3 F Thermostat Installation and Operation There is a 4 screw terminal block located on the back lower left corner of the stove directly...

Страница 23: ...REPLACE BATTERY warning begins flashing The warning flashes about two months before the batteries are depleted Even if the warning does not appear you should replace batteries once a year If batteries...

Страница 24: ...CFR 3280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 24 1 CAUTION Never draw outside combustio...

Страница 25: ...November 30 2017 7014 258B 25 CB1200 FREESTANDING 8 Accessory List A Service Maintenance Log Date of Service Performed By Description of Service...

Страница 26: ...26 7014 258B November 30 2017 CB1200 FREESTANDING Date of Service Performed By Description of Service...

Страница 27: ...er Outside Air Kit Floor 411 1071 Hose Alum Flex 2 Inch x 3 Ft Qty 3 Ft Req SRV200 0860 Outside Air Cap Assembly 7001 044 Outside Air Collar Assembly SRV7001 045 Trim Plate Outside Air Kit 412 7100 Sm...

Страница 28: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...

Отзывы: