May 12, 2014
7021-130F
Page 15
Castile-B FS Pellet Stove
We recommend a minimum of 60 in.
(1.5m) vertical, however above the eave
is preferred.
Both installations are approved for
mobile home installations. Must use
3 or 4 inch (76 to 102mm) “L” or “PL”
listed pellet venting or listed double
wall pipe and Quadra-Fire Outside Air
Kit in mobile homes. Single wall pipe
is approved for residential installations
only.
C. Vertical
D. Through The Wall & Vertical
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
Clean-out Cover
24 in. (610mm)
Minimum
Ceiling Support
6 in. (152mm) Flue
Connector
6 in. (152mm) Class A
Chimney Connector
Adapter
3 in. to 6 in.
(76-152mm)
Top Vent Kit
Figure 15.1
Figure 15.2
Non-combustible Hearth Pad
Clean-out Cover
Support Bracket
every 60 in. (1.5m)
24 in. (610mm) minimum
Rain Cap
Flashing
2 in. (51mm) minimum
6 in. (152mm)
minimum
Tee
Wall Thimble