You must use a Quadra-Fire Outside Air Kit for 

installation in a mobile home.

1.  An outside air inlet must be provided for the combustion 

air and must remain clear of leaves, debris, ice and/or 

snow.  It must be unrestricted while the appliance is in 

use to prevent room air starvation which causes smoke 

spillage.  Smoke spillage can also set off smoke alarms.  

2.  The combustion air duct system must be made of metal.  

It must permit zero clearance to combustible construction 

and prevent material from dropping into the inlet or into 

the area beneath the dwelling and contain a rodent 

screen.

3. The appliance must be secured to the mobile home 

structure by bolting it to the floor (using lag bolts).  Use 

the same holes that secured the appliance to the shipping 

pallet.

4. The appliance must be grounded with #8 solid copper 

grounding wire or equivalent, terminated at each end with 

an NEC approved grounding device.

5.  Refer to Clearances to Combustibles and floor protection 

requirements on page 8  for listings to combustibles and 

appropriate chimney systems.

6.  Use  silicone  to  create  an  effective  vapor  barrier  at 

the location where the chimney or other component 

penetrates to the exterior of the structure.

7. Follow the chimney manufacturer’s instructions when 

installing the vent system for use in a mobile home.

8.  Installation shall be in accordance with the Manufacturers 

Home & Safety Standard (HUD) CFR 3280, Part 24.

PART NUMBER: 811-0872

Spark Arrestor Cap 

Roof Flashing 

Storm Collar

Joist Shield/Firestop 

Double Wall 

Connector Pipe  

Figure 24.1

Mobile Home Installation 

Products of combustion generate carbon monoxide and 

different fuels generate different levels. Carbon monoxide
•  Only use approved fuels in this appliance.
•  Always keep door shut during operation. Operating 

this appliance with doors open can allow CO to leak 

into the home.

CO can kill you before you are aware it is in your home. 

At lower levels of exposure, CO causes mild effects 

that  are  often  mistaken  for  the  flu.  These  symptoms 

include headaches, dizziness, disorientation, nausea 

and fatigue. The effects of CO exposure can vary greatly 

from person to person depending on age, overall health 

and the concentration and length of exposure.

WARNING

THE STRUCTURAL INTEGRITY OF THE MOBILE 

HOME FLOOR, WALL AND CEILING/ROOF MUST BE 

MAINTAINED

Do NOT cut through:

•  Floor joist, wall, studs or ceiling trusses.

•  Any supporting material that would affect the structural 

integrity.

This  appliance  is  to  be  connected  to  a  factory-built 

chimney  conforming  to  CAN/ULC-S629,  Standard  for 

650°C Factory-Built Chimneys.

For removal of the chimney for mobile home 

transportation, contact the proper transportation officials.

CAUTION

Never draw outside combustion air from:
• 

Wall, floor or ceiling cavity

•  Enclosed space such as an attic or garage

CAUTION

It is critical to have a working smoke detector 

installed in the home of appliance operation.

 

•  Smoke alarms that are properly installed and 

maintained play a vital role in reducing fire deaths and 

injuries. Having a working smoke alarm reduces the 

chance of fire related injuries..

WARNING

NEVER INSTALL IN A SLEEPING ROOM.

WARNING

Содержание CASTILE-B

Страница 1: ...ction about restrictions installation inspection and permits CAUTION WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not ov...

Страница 2: ...ls And Supplies Needed 6 D Inspect Appliance and Components 6 E Install Checklist 7 3 Dimensions and Clearances A Appliance Dimensions 8 B Clearances to Combustibles UL and ULC 10 C Hearth Pad Require...

Страница 3: ...tions to operate this pellet appliance in a manner inconsistent with operating instructions in this manual Emissions Report Number 0061PM077E EPA Certification 175 19 EPA Certified Emissions 1 1 grams...

Страница 4: ...erial that can ignite and burn flame proofed or not plastered or non plastered H Sleeping Room When installed in a sleeping room it is recommended that 3ft of vertical be installed prior to horizontal...

Страница 5: ...fficient additional support to meet this weight requirement prior to installation The weight of the appliance is 208 lbs Installation MUST comply with local regional state and national codes and regul...

Страница 6: ...all the parts and articles packed inside the Component Pack Inspect all the parts and glass for shipping damage Report to your dealer any parts damaged in shipment All labels have been removed from th...

Страница 7: ...ng this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appliance Check...

Страница 8: ...op View with TPVNT 6 and 811 0720 5 3 4 in 146mm 3 1 2 in 89mm Figure 8 2 Top View with TPVNT 2 and 812 3570 5 in 127mm 11 7 8 in 297mm 3 in 76mm 1 3 4 in 44mm Figure 8 4 Top view with TPVNT 2 and 811...

Страница 9: ...Figure 9 4 Side View with TPVNT 2 and 811 0720 28 5 8 in 727mm 27 in 686mm Figure 9 3 Side View with TPVNT 6 and 811 0720 24 1 2 in 622mm 22 7 8 in 581mm Figure 9 2 Side View 22 7 8 in 581mm 17 in 43...

Страница 10: ...preference Horizontal Through the Wall Inches Millimeters A Back Wall to Appliance 2 51 B Side Wall to Appliance 6 152 Corner Installation Inches Millimeters C Walls to Appliance 2 51 C C A B Vertical...

Страница 11: ...m to both sides of the fuel loading door Open the door and measure 6 inches 152mm from the side edge of the opening in the face of the appliance See exception CAUTION Hearth and Home Technologies does...

Страница 12: ...a All minimums listed are to a combustible surface NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation...

Страница 13: ...e P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in Above grass top of pla...

Страница 14: ...mands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation to t...

Страница 15: ...sful draft include Preventing negative pressure Location of appliance and chimney E Chimney and Exhaust Connection 1 Chimney Connector Use 3 or 4 inch 76 102mm diameter type L or PL venting system It...

Страница 16: ...ch your altitude above sea level 3 If you fall below the diagonal line 3 or 4 inch 76 to 102mm pipe may be used 4 If it is anywhere above the diagonal line a 4 inch 102mm diameter pipe is required Pel...

Страница 17: ...ust use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage through a wall or partition of comb...

Страница 18: ...4 in 610mm Minimum Ceiling Support 6 in 152mm Flue Connector 6 in 152mm Class A Chimney Connector Adapter 3 in to 6 in 76 152mm Top Vent Kit B Vertical into Existing Class A Chimney We recommend a min...

Страница 19: ...1 in 25mm clearance with firestop 6 in 152mm minimum Fireclay Flue Liner with airspace Concrete Cap Fire Risk Inspection of Chimney Masonry chimney must be in good condition Meets minimum standard of...

Страница 20: ...aw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage CAUTION 4 Measure distance from floor to air vent opening in appliance and mark location on wall U...

Страница 21: ...t Do not put silicone inside of pipe Figure 21 1 2 Slide the adapter onto the rear exhaust outlet and adjust the assembly to the appropriate position 3 Install the vent pipe into the adapter Follow ve...

Страница 22: ...ends are held ALL the way into the terminal block while the screws are being tightened 7 Snap the thermostat to the base plate 6 There are two AA ALKALINE ONLY batteries already installed into the the...

Страница 23: ...rasive nature of a pellet appliance fire the logs are not covered under warranty Any placement variation other than shown here can cause excessive heat and shall void the appliance warranty E Leg Leve...

Страница 24: ...Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 24 1 7 7 Mobile Home Installation Products of combustion generate carbon monoxide and different fuels generate differ...

Страница 25: ...25 08 22 7021 801F A Service and Maintenance Log Date of Service Performed By Description of Service 8 8 Reference Materials...

Страница 26: ...26 08 22 7021 801F Date of Service Performed By Description of Service...

Страница 27: ...llar Offset Top Vent 812 3570 Damper 3 Inch Tall Vertical Installs Only PEL DAMP3 Y Damper 4 Inch Tall Vertical Installs Only PEL DAMP4 Outside Air Kit Rear 811 0872 Channel Air Intake SRV413 7040 Cov...

Страница 28: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: