CAUTION:  

H

OT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, 

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.  SEE 

NAMEPLATE AND INSTRUCTIONS.  Operate this unit only with fuel hopper lid closed.  

Failure to do so may result in emissions of products of combustion from the hopper 

under certain conditions.  Maintain hopper seal in good condition.  Do 

not

 

over fill the 

hopper.

ATTENTION

:  

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS 

LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU.  VOIR 

L'ÉTIQUETTE ET LES INSTRUCTIONS.  

Opérez cet appareil uniquement avec le couvercle de la trémie fermé. Le défaut de ne pas 

suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne 

pas remplir la trémie trop pleine.

7014-197C

Report / Rapport

061-S77d-6.2

BARCODE LABEL

HF

Serial No. / 

N

o

 de série:

®

Castile Pellet Stove

Appareil de chauffage solide/de type de boulettes. Accepté dans l’installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour i’usage dans les 

Maisons Mobiles en accord avec OAR 814-23-9000 jusqu’à 814-23-909. OMNI-Test laboratories, Inc. a déterminé que cet appareil se conforme avec la norme de 

l’Association Canadienne de normalisation (CSA) B415.1 ainsi que le Titre 40 du Code Fédéral de Régulations des États-Unis, partie 60, sous-partie AAA. Accréditations 

OMNI-Test Laboratories : Le conseil Canadien des Normes (CCN/SCC), l’Institue des Standards Nationaux Américan (ANSI) et l’Agence de Protection Environmental 

(EPA).
Testé à: ASTM E1509-04, ULC S627-00, ULC/ORD-C1482-M1990 Room Heating Pellet Burning Type, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE 

BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS. N’utiliser aucun autre genre de combustible puissance de Rendement: 38,700 Btu’s/hr. Puissance 

l’appereil. Ne pas bloquer l’espace au dessous de l’appareil.

DANGER:

 Risque de décharge électrique. Déconnectez le dil électrique de la prise de contact avant le service.

Remplacez la vitre seulement avec une vitre céramique de 5 mm disponsible chez votre fournisseur.
Pour allumer, monter la température du thermostat en dessous de la température de oa pièce. Pour des instructions supplémentaires, référez vous au manel du 

propriétaire. Gardez la porte d’ouverture et la porte des cendres fermées hermétiquement durant l’opération.

PRÉVENTION DES FEUZ DE MASON - 

Installez et utilisez en accord avec les instructions d’installation et d’opération du fabricant. Contactez le bureau de la constuction 

ou le bureau des incendies au sujet des restrictions et des inspections d’installation dans votre voisinage. Ne pas obstruex l’espace en dessous de l’appareil.

AVIS - Pour les Maisons Mobiles:

 Ne pas installer dans une chambre à coucher. Un tuyau extérieu de combustion d’air doit être maintenue intacte.

Référez vous aux instructions de fabricant et des codes locaux pour les précautions requises pour passer une cheminée à travers un mur ou un plafond combustibles, et 

les compemsations maximums. Inspectez et nettoyez la cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un autre appareil. Utilisez systèm 

de ventilation “L” ou “PL” diamètre 76mm ou 102mm.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

Note 1:

 In residential installations, when using Perts 811-0890, (3” - 3” Top Vent Adapter) and 812-3570 (3” - 6” Offset Adapter), 24 gauge 

Note 1:

 Dans les installations résidentielles. Lorsque les pièces 811-0890, (dessus de l’adapteur 76mm - 76mm) et 812-3570 (dessus de 

l’adapteur 76mm - 152mm), un tuyau connecteur de 6” pour mur simple de calibre 24 peut être utilisé.

Note 2:

 In manufactured home installation, when using Part 811-0890, (3” - 3” Top Vent Adapter) and (3” - 6” Offset Adapter), use listed 

Note 2:

 Pour l‘utilisation dans les maisons prèfabriquées, lorsque les pièces 811-0860, (dessus de l’daptateur d’ventilation 76mm - 76mm) 

et 812-3570 (le ressaut de l’adapteur 76m - 152mm), utilisez un tuyau connecteur evregistré pour mur double. Un assemblage d’air extérieur 

(pièce 811-0872), doit être utilisé pour l’installation dans les maison préfabriquées.

C

C

A

B

“B” is to Cast Top

(“B” du haut)

D

E

“E” is to Cast Top

(“E” du haut)

F

F

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:

A  Back Wall to Stove / Mur Arrière du poêle 

2” / 51mm

B  Side Wall to Cast Top / Mur De Côté du haut 

6” / 152mm

Corner Installation / Installation du Coin:

C  Side Wall / Mur De Côté 

2” / 51mm

Vertical 3 in. - 6 in. Adapter Kit (Part #812-3570 Installation / Unassemblage Pour 

Adapteur 76mm - 152mm (Pièce 812-3570 Pour Installation verticale:

D  Back Wall to Flue Pipe / Mur Arrière tuyau rigide 

3” / 76mm

E  Side Wall to Cast Top / Mur De Côté du haut 

6” / 152mm

Corner  Installation  with  Vertical  Adapter  Kit  /  Installation  du  coin  avec  un 

assemblage d’adapteur verticale:

F  Side Wall / Mur De Côté 

2” / 51mm

Alcove Installation / Installation de l’alcove:

Min. Alcove Height / Une hauteur minimum de l’alcove: 

43” / 1092mm

Min. Alcove Side Wall / Une hauteur minimum mur de côté de l’alcove:  6” / 152mm
Max. Alcove Depth / La profondeur maximum de l’alcove: 

36” / 914mm

G

G

I

H*

USA

G = 6” / 152mm

H* = 2” / 51mm

I  = 6” / 152mm
Canada

G = 203mm

H* = 51mm

I  = 457mm

FLOOR PROTECTION / PROTECTION DU SOL

pipe  when  installed  with  horizontal  venting  or  under  the  Top 

Vent Adapter with vertical installation. 

Recommended in USA; 

Required in Canada.

Floor  protection  must  be  non-combustible  material,  extending 

beneath heater and to the front/sides/rear as indicated. Measure 

front distance (I) from the surface of the glass door.
*La protection du sol non combustible doit se prolonger sous la 

conduite de fumée lorsqu’elle est installée avec une ventilation 

horizontale ou sous l’adaptateur de ventilation supérieure avec 

une  installation  verticale.  Recommandé  aux  USA;  Obligatoire 

au Canada.
La protection du sol doit être incombustible, s’étendant sous le 

radiateur et à l’avant / aux côtés / à l’arrière comme indiqué. 

Mesurer la distance avant (I) à partir de la surface de la porte 

vitrée.

7021-131_R6

Date of Manufacture / Date de fabrication:

2017   2018   2019   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

U.S. Environmental Protection Agency

A Method 28 & 5G. Not approved for sale after May 15, 2020

This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s Manual for further information. It is against federal 

regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ETIQUETTE

Made in the U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

Listed solid fuel Room Heater/Pellet Type. Also suitable for Mobile Home Installation. This appliance has been tested and listed for use in 

Manufactured Homes in accordance with OAR 814-23-9000 through 841-23-909. OMNI-Test Laboratories, Inc. has determined that this 

appliance complies with Canadian Standards Association (CSA) B415.1 and Title 40 of the U.S. Code of Federal Regulations, Part 60, SubPart 

AAA.OMNI-Test Laboratories Accreditations: The Standards Council of Canada, the American National Standards Institute, and the U.S. 

Environmental Protection Agency.

Tested to: ASTME E1509-04, ULC S627-00, ULC/ORD-C1482-M1990 Room Heating Pellet Burning Type, (UM) 84-HUD FOR USE ONLY WITH 

PELLETIZED WOOD OR SHELLED FIELD CORN FUEL. Do not use any other type of fuel.

Input Rating: 38,700 Btu’s/hr  Electrical Rating: 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps. Route power cord away from unit. Do not route 

cord under or in front of appliance. Do not obstruct the space beneath the heater.

DANGER: 

Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm ceramic available from your 

dealer. To start, set thermostat above room temperature, the stove will light automatically. To shutdown, set thermostat to below room 

temperature. For further instruction refer to owner’s manual. Keep viewing and ash removal doors tightly closed during operation.

PREVENT HOUSE FIRES

 - Install and use only in accordance with manufacturer’s installation and operating instructions. Contact local 

building or fire officials about restrictions and inspections in your area.

WARNING - FOR MOBILE HOMES: 

Do not install appliance in a sleeping room. An outside combustion air inlet must be provided. The structural 

integrity of the mobile home floor, ceiling and walls must be maintained.

DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE. 

 Use a 3 in or 4 in diameter type”L” or “PL” venting system.

A. Sample of Serial Number / Safety Label

LOCATION:  Back of Appliance

Serial No.

S A

M P

L E

Model 

Name

Test Lab & 

Report No.

Mfg. Date

NOTE: Clearances may only be reduced by means approved by 

the regulatory authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Содержание CASTILE-B series

Страница 1: ...ons installation inspection and permits Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies recommends HHT Factory Trained or NFI certified p...

Страница 2: ...ner Installation Installation du Coin C Side Wall Mur De C t 2 51mm Vertical 3 in 6 in Adapter Kit Part 812 3570 Installation Unassemblage Pour Adapteur 76mm 152mm Pi ce 812 3570 Pour Installation ver...

Страница 3: ...Your First Fire 10 F Filling the Hopper 10 G General Operating Information 10 H Starting Your First Fire 11 I Fire Characteristics 11 J Feed Rate Adjustment Instructions 11 K Ignition Cycles 12 L Rest...

Страница 4: ...lectronic components and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceram...

Страница 5: ...arranging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warran...

Страница 6: ...ue to water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS...

Страница 7: ...N A EPA BTU Output 8 500 to 28 200 hr BTU Input 11 600 to 38 700 hr Vent Size 3 4 or 6 inches L or PL Hopper Capacity 45 lbs Fuel Wood Pellets Weighted average LHV efficiency using data collected duri...

Страница 8: ...installed in a sleeping room it is recommended that 3ft of vertical be installed prior to horizontally exiting the room and a smoke CO alarm be installed in the bedroom The size of the room must be at...

Страница 9: ...Plaster Brick Iron Concrete Tile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method for Behavior of Metals in a Vertical Tube Furnace of 750 C Wood Compressed Paper Plant Fiber...

Страница 10: ...on instructions 2 Double check that the ash drawer and firebox are empty 3 Close the front door IMPORTANT DETAIL The tip of the thermocouple must be in contact with the inside end of the thermocouple...

Страница 11: ...t the feed rate may require a slight adjustment If the appliance is running all of the time 100 corn will work after the fire has been started using wood pellets I Fire Characteristics A properly adju...

Страница 12: ...ts NOTICE Clearances may only be reduced by means approved by the regulatory authority having jurisdiction Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of...

Страница 13: ...tart with item 01 and is advanced to each following item by a single press of the NEXT button The options for each item are changed using the UP or DOWN buttons ITEM 01 CLK CLOCK FORMAT 12Hr default T...

Страница 14: ...P or DOWN The temporarily changed set temperature will return to the programmed value stored in memory when start time of the next upcoming scheduled event is reached MORN DAY EVE OR NITE While the te...

Страница 15: ...libration 1 Move TEMPERATURE switch to OFF 2 Move SET switch to RUN 3 Press and hold both UP and DOWN buttons together for at least 5 seconds the words SET and CAL will appear on the display along wit...

Страница 16: ...he LO BATT appears on the display screen The batteries are located on the back of the thermostat s circuit board The front portion of the thermostat can be removed from the back half by using the tabs...

Страница 17: ...the operation or longevity of your insert 2 Ash buildup on glass 2 This is normal Clean the glass 3 Glass has turned dirty 3 Excessive build up of ash The lower burn settings will produce more ash th...

Страница 18: ...R X Glass When clear view of fire pot becomes obscured OR X Heat Exchanger Drop Tube Every 1 ton of fuel OR X Hopper Every 1 ton of fuel or when changing fuel types OR X Venting System More frequently...

Страница 19: ...the left and right of the fire pot are 2 cleaning slide plates with finger holes Pull both slide plates out and then open the glass door Sweep the remaining ash from the firebox into the 2 open holes...

Страница 20: ...baffle This will require removing the cast baffle Please refer to page 35 for a detailed explanation of removing the baffle WARNING Heat exchanger cleaning rods may be warm to the touch For safety pur...

Страница 21: ...s 11 Cleaning the Glass Frequency When clear view of the fire pot becomes obscure By Homeowner a Appliance must be completely cool before cleaning glass b Vacuum fly ash from glass and door rope c Use...

Страница 22: ...fuel is shown in Figure 22 2 The correct flame size when good quality premium pellet fuel is burned is shown in Figure 22 3 If the ash buildup exceeds the half way point in the fire pot IMMEDIATE ATT...

Страница 23: ...control box Call light on No fire Partially burned fuel in fire pot Fire pot clean out plate not closed Fire pot is dirty missed ignition Check that fire pot clean out plate is fully closed Clean fire...

Страница 24: ...g loss of vacuum Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 screws and jiggle feed assembly C...

Страница 25: ...ick panels Change fuel brand to premium Check that fire pot clean out plate is fully closed Reduce feed rate using feed rate adjustment control rod located inside hopper Nuisance shutdowns Low flame S...

Страница 26: ...thermostat and let the appliance completely cool down After the appliance has cooled down unplug it and remove the ash drawer 2 The wire leads to the igniter are connected to the wire harness with 1 4...

Страница 27: ...the back 2 screws and nuts 4 total that is securing the blower to the housing g Remove blower and replace with new blower h Re install in reverse order Figure 27 3 Combustion Blower Remove 6 screws Fi...

Страница 28: ...epeat for left brick Figure 28 3 Remove Right Left Brick Vacuum Exhaust Area Right Brick Removed E Baffle Brick Set Installation 1 Place right brick in behind the right bracket and then slide to the l...

Страница 29: ...021 155H CASTILE FREESTANDING Right Brick Installed Lift Brick pull forward at an angle and drop down into notches Opening at left side of Baffle Insert Baffle Tab into Slot Figure 29 3 Figure 29 4 Fi...

Страница 30: ...6 times in a row for 60 seconds and then will stop E NOTE Do NOT open the control box This will void the warranty If you need to plug in or remove the control box you must first unplug the appliance...

Страница 31: ...t itself 19 Snap Disc 3 Back Burn Protector 250 F Snap disc 3 is mounted on the back of the auger tube in the center of the appliance and has a reset button To access it remove the right side panel If...

Страница 32: ...ed Motor High Med Low Heat Output Switch Reset Button Reset Button Combustion Blower TERMINAL BLOCK CENTER 2 SCREWS FOR THERMOSTAT WIRES POWER OUTLET FUSE Fuse Red Call Light is located on top of Junc...

Страница 33: ...33 February 11 2019 7021 155H CASTILE FREESTANDING C Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 34: ...Date Oct 2009 Ending Manufacturing Date Active 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 30 25 26 27 28 29 Castile Pellet Freestanding Stove CASTILE CSB B CASTILE MBK B CASTILE PM...

Страница 35: ...7021 101CWL 3 Cast Retainer Upper SRV7021 141 4 Convection Air Director SRV7021 123 5 Hinge Bracket SRV7021 115 6 Outer Skin Left SRV7021 119 7 Brick Left Right Cast SRV414 0270 8 Brick Center Cast SR...

Страница 36: ...3 0010BK Mahogany 413 0010PMH Porcelain Color 413 0010POR Powder Coat 413 0010PWD 13 Face Black 413 0030BK Mahogany 413 0030PMH Porcelain Color 413 0030POR Powder Coat 413 0030PWD 14 Door Assembly No...

Страница 37: ...er Lower Right Assembly SRV7021 021 22 Side Black SRV7021 125MBK Mahogany SRV7021 125PMH Sienna Bronze SRV7021 125CSB No longer available SRV7021 125CWL 23 Convection Plenum Back SRV7021 120 24 Outer...

Страница 38: ...g Assembly 7000 000 Paint Touch Up 4 Oz Matte Black 812 0910 Mahogany 855 1450 Sienna Bronze TOUCHUP CSB Power Cord 812 1180 Y De ector Bottom Airwash 413 0680 Feed Adjustment Plate 7001 182 Fuse 7 Am...

Страница 39: ...e Air Collar Assembly SRV7001 045 Trim Plate Outside Air Kit 412 7100 Pullrod Handle PULLROD HNDL Thermostat programmable PROG STAT Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical...

Страница 40: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...

Отзывы: