Quadra-Fire Adventure-III Скачать руководство пользователя страница 21

With proper installation, operation, and maintenance your wood burning appliance will provide years of trouble-free service. 

If you do experience a problem, this troubleshooting guide will assist you or a qualified service person in the diagnosis of a 

problem and the corrective action to be taken. 

Start Fire Problems

Possible Cause

Solution

Can not get fire started 

Excessive smoke or 

spillage 

Burns too slowly 

Not enough heat output

Not enough kindling/paper 

or no kindling/paper

Use dry kindling, more paper. Arrange kindling & wood for air 

movement.

Not enough air for fire to 

ignite

Check for restricted termination cap
Check for blockage of outside air kit (if installed).
Check for flue blockage.
Pre-warm flue before starting fire (refer to Building a Fire 

Section).
Check for adequate vent height. 14 to 16 foot minimum.

Open window below the appliance towards the wind.

Wood condition is too wet, 

too large

Use dry, seasoned wood (refer to Seasoned Wood Section).

Bed of coals not 

established before adding 

wood

Start with paper & kindling to establish bed of coals (refer to 

Building a Fire Section).

Flue blockage such as 

birds’ nests or leaves in 

termination cap

Have chimney and cap inspected and cleaned by a certified 

chimney sweep.

Down draft or negative 

pressure 

Competition with exhaust 

devices

Do not use exhaust fans during start-up.

Open window below the appliance towards the wind.

Activation button not 

pressed when starting fire

Press activation button and ensure that the indicator light 

turns solid green.

Actuator on air control 

did not move to full open 

position

In all cases the air control will move to the full open position 

after pressing the activation button.  A visual check of this 

may be in order or follow the field diagnostics guide.

Blinking red light indicated 

on activation button

This is indicating a fault of a component in the appliance.  

Refer to the diagnostics guide to analyze the blinking and to 

diagnose further. Do not operate appliance.

No AC power to appliance

Check that the power cord on the back of the appliance is 

plugged in all the way and that the power cord is plugged into 

an operational wall outlet.

Low Batteries or NO 

batteries placed in battery 

backup appliance

Low voltage of the battery pack or lack of batteries in the 

backup battery pack will not allow operation of system if 

regular AC power is not available.  Replace batteries.

Air control disconnected 

from actuator due to 

previous disconnecting 

If the air control was disconnected due to no regular AC 

power/ no batteries or low battery voltage condition then it will 

be necessary to reattach the air control to the actuator. 

Troubleshooting Guide

21

Quadra-Fire • Adventure-III Owner’s Manual • 4083-900 • Rev D • 09/15

Содержание Adventure-III

Страница 1: ...injury or death WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glas...

Страница 2: ...enance Log 26 B Service Parts Accessories 27 C Contact Information 32 1 Welcome A Congratulations 3 B LIMITED LIFETIME WARRANTY 4 2 Product Specific Information A Appliance Certification 6 B BTU Effic...

Страница 3: ...ps 60 Hz Route power cord away from unit Do not route cord under or in front of appliance DANGER Risk of electrical shock Disconnect power supply before servicing Replace glass only with 5mm ceramic a...

Страница 4: ...on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no l...

Страница 5: ...a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated o...

Страница 6: ...connector glows you are overfiring Any such action that may cause a fire hazard A Appliance Certification NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its p...

Страница 7: ...e materials gasoline and other flammable vapors and liquids clear of the appliance Do NOT store flammable materials close to the appliance use gasoline lantern fuel kerosene charcoal lighter fluid or...

Страница 8: ...cause a structure fire Ceramic Blanket and Baffle Board are NOT in contact with the back of the firebox Ceramic Blanket is NOT in contact with the back of the firebox and NOT even with the Baffle Boa...

Страница 9: ...insulating proper ties Do not operate the appliance without bricks and refractory board in place Make sure bricks are installed as shown in Figure 3 3 Do not use a grate simply build a fire on the fi...

Страница 10: ...othing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down Figure 3 4 General Operating Parts 5 Fan Speed Control option...

Страница 11: ...calling for heat then the light stays green for as long as the appliance is burning on high No Light The appliance will progress into a shutdown phase and slowly cool down and the light will turn off...

Страница 12: ...nwanted time periods except Wake Saturday and Sunday can be programmed individu ally by changing the format from 5 2 to 5 1 1 To change the format 1 Press and hold the up button and the center button...

Страница 13: ...Materials containing asbestos 7 Construction or demolition debris 8 Railroad ties or pressure treated wood 9 Manure or animal remains However if at all possible the best arrangement is to have a mix o...

Страница 14: ...s high a moisture content now as it did when it was cut To season wood Cut logs to size Split to 6 in 152 mm or less Air dry to a moisture content of around 20 Soft wood about nine months Hard wood ab...

Страница 15: ...t least annually be fore lighting or once every two months during heating season When creosote has accumulated it should be removed to reduce the risk of a chimney fire D Building a Fire 1 First Fire...

Страница 16: ...second Left thermocouple error call your dealer 3 fast red blinks then no color for 1 second Right thermocouple error call your dealer 1 red blink every 1 2 second continually Overfire indication do n...

Страница 17: ...tton on the thermostat to start the programmed event 3 Lighting the Fire 1 Set the thermostat to the desired temperature 2 Push the SBT button the air control will open and the light should illuminate...

Страница 18: ...illness or possible death Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance WARNING Do NOT store flammable materials in the appliance s vicinity...

Страница 19: ...ill pull it out replace the door gasket Check the glass frame for loose screws to prevent air leakage Check glass for cracks WEEKLY or After Every 25 Loads of Wood Check the door latch for proper adju...

Страница 20: ...mney once every two months during heating season Remove creosote to reduce risk of chimney fire Ignited creosote is extremely HOT Fire Risk Disposal of Ashes WARNING Ashes should be placed in metal co...

Страница 21: ...re Competition with exhaust devices Do not use exhaust fans during start up Open window below the appliance towards the wind Activation button not pressed when starting fire Press activation button an...

Страница 22: ...the field diagnostics to perform some testing Thermocouples in appliance are no longer in proper position The theromocouples that sense the condition of the fire in the appliance must be in the prope...

Страница 23: ...hutdown too quickly or too much heat when commanded to shutdown Three fast blinks of red light then long off 1 sec Right Thermocouple burned out open circuit Appliance will exhibit either late or prem...

Страница 24: ...glass Avoid striking scratching or slamming glass Do NOT clean glass when hot Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Refer to maintenance instructions CAUTIO...

Страница 25: ...ed the guards will come down 8 Next you will need to remove 2 screws from the side panel of the appliance for the thermocouple that you are replacing The screws are found on the back side of the appli...

Страница 26: ...Date of Service Performed By Description of Service A Service Maintenance Log 7 Reference Materials 26 Quadra Fire Adventure III Owner s Manual 4083 900 Rev D 09 15...

Страница 27: ...Baf e Blanket SRV4083 205 4 Baf e Qty 2 req SRV4083 113 5 Thermocouple Qty 2 req SRV4083 147 6 Sensor Shield 2 pcs SRV4083 212 Door Assembly See Following Pages Manifold Tube Set TUBES 4083 Y 7 Manifo...

Страница 28: ...12 Pedestal Assembly SRV4083 017 12 1 Control Plate Assembly SRV4083 035 12 2 Battery Backup SRV4083 177 Y 12 3 Pedestal Catch Bracket SRV4083 197 12 4 Pedestal Door Assembly SRV4083 033 12 5 Door Han...

Страница 29: ...SRV4083 202 16 3 Brick 9 15 16 x 4 1 2 x 1 1 4 Qty 6 req SRV4083 208 16 4 Brick 13 1 4 x 4 1 2 x 1 1 4 Qty 14 req SRV7000 306 17 Refractory Assembly SRV4083 026 17 1 Refractory Bottom Qty 3 req SRV40...

Страница 30: ...Pins 1 2 Qty 2 Gold 832 0250 Qty 2 Nickel 430 5320 19 2 Rope Door 3 4 x 84 Field cut to Size 7 Ft Length 832 1680 Y 19 3 Door Glass Assembly 17 5 8 W x 11 1 2 H 7000 014 Y Gasket Glass Tape Field cut...

Страница 31: ...Wire Harness AC SRV4083 176 Y Wire Harness Blower AC SRV4083 178 Y Manifold Clip Screw 832 0661 Component Pack SRV4083 030 Power Cord 812 1180 Y Wire Harness TSTAT Block SRV7080 152 Y Thermostat Progr...

Страница 32: ...oduct may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending DO NOT DISCARD THIS MANUAL CAUTION Important...

Отзывы: