12
7038-206E
August 3, 2015
5700 STEP TOP
B. Chimney Systems
•
The chimney connector joins the stove to the chimney.
• It must be a 6 inch (152mm) minimum diameter 24 gauge
mild steel black or 26 gauge blued steel.
• Or an approved air-insulated double wall venting pipe.
Single wall connector or stove pipe
• Must be at least 24 gauge mild steel or 26 gauge blue
steel.
• Sections must be attached to the appliance and to each
other with the crimped (male) end pointing toward the
stove.
• All joints, including the connection at the fl ue collar, should
be secured with 3 sheet metal screws.
• Follow the minimum clearances to combustibles
Factory-built chimney connector (vented)
• A Listed connector (vented) must be used when installing
this unit in a mobile home.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
the owner’s information manual provided with this appliance.
For assistance or additional information consult a qualifi ed
installer, service agency or your dealer.
WARNING
Chimney Flue
Liner
Fireclay
Liner or
Equivalent
Masonry Chimney
Constructed to NFPA 211
Wall Spacer
Wall Band
Trim Collar
Chimney
Connector
1 inch (25mm) Air
Space to Chimney
Section
Min. Clearance
2 inch (51mm)
Min. Chimney Clearance to
Wall Spacer and
Combustibles - 2 inch (51mm)
Chimney Section
Figure 12.3
LINER CONNECTOR
FLUE
GAS
DIRECTION
CRIMPED
END
TOWARDS
STOVE
Figure 12.2 Chimney Connector (Stove Pipe)
Trim Collar
Chimney Section
with 2 inch
(51mm)
Clearance to
Combustibles
Chimney
Connector
Fire Clay Flue
Liner
with Airspace
Masonry
Chimney
Wall Band to
Secure Chimney
Section
Wood Studs Used
for Framing - Spaced
2 inch (51mm)
clearance from
Masonry Chimney
Wall Spacer
Solid Pack Chimney with Metal Supports as a Thimble
Figure 12.1
• The Listed connectors must conform to each other to
ensure a proper fi t and seal.
C. Chimney Height / Rise and Run
• This product was designed for and tested on a 6 inch
(152mm) chimney, 14 to 16 feet (427-487cm) high, (in-
cludes appliance height) measured from the base of the
appliance.
• The further your stack height or diameter varies from this
confi guration, the possibility of performance problems
exists.
• Chimney height may need to be increased by 2 - 3% per
each 1000 feet (304.8m) above sea level.
• It is not recommended to use offsets or elbows at altitudes
above 4000 feet (1219.2m) above sea level or when there
are other factors that affect fl ue draft.
D. Installing Chimney Components
Chimney Connector
Single wall connector or stove pipe.
This must be at least 24 gauge mild steel or 26 gauge blue
steel. The sections must be attached to the appliance and to
each other with the crimped (male) end pointing toward the
stove. All joints, including the connection at the fl ue collar,
should be secured with 3 sheet metal screws. Make sure
to follow the minimum clearances to combustibles. Where
passage through the wall, or partition of combustible con-
struction is desired in Canada, the installation shall conform
to CAN/CSA-B365.
Factory-built listed chimney connector (vented).
A listed connector (vented) must be used when installing this
unit in a mobile home. The listed connectors must conform
to each other to ensure a proper fi t and seal.