background image

September 27, 2016 

 

 

 

 

           7038-206F 

 

 

         

                 13

5700 STEP TOP ACC

NOTE: I

n Canada when using a factory-built chimney it must 

be safety listed,

 Type UL103 HT (2100

o

F) CLASS “A” 

or 

conforming to 

CAN/ULC-S629M, STANDARD FOR 650

o

FACTORY-BUILT CHIMNEYS.

Floor

Protector

Chimney

Connector

Insulated " T "

Flashing

Listed Termination Cap

Trim Collar on

Inside Wall

Listed Chimney

Storm Collar

Wall Support

Roof Brace (if required)

Thimble

Figure 13.1 Prefabricated Exterior Chimney

E.  Venting Components 

Chimney Connector:

It is also known as flue pipe or appliance pipe.  The chimney 

connector joins the appliance to the chimney.  It must be a 6 

inch (152mm) minimum diameter 24 gauge mild steel black 

or 26 gauge blued steel, or an approved air-insulated double 

wall venting pipe.  

Thimble

:  

A manufactured or site-constructed device installed in 

combustible walls through which the chimney connector 

passes to the chimney.  It is intended to keep the walls 

from igniting.  Site constructed thimbles must meet NFPA 

211 Standards.  Prefabricated must be suitable for use with 

selected chimney and meet UL103 Type HT Standards.  Follow 

instructions provided by the manufacturer for manufactured 

thimbles for masonry chimney and prefabricated chimneys.

F.  Chimney Systems

Prefabricated Metal Chimney

•  Must be minimum 6 inch (152mm) diameter (ID) high 

temperature chimney listed to UL 103 HT (2100

o

F) or 

ULC S629M.

•  Must use components required by the manufacturer 

for installation.

•  Must maintain clearances required by the manufacturer 

for installation.

•  Refer to manufacturers instructions for installation.

D. Chimney Height / Rise and Run

This product was designed for and tested on a 6 inch (152mm) 

chimney, 14 to 16 feet (420-480cm) high, (includes appliance 

height) measured from the base of the appliance.  The further 

your stack height or diameter varies from this configuration,  

the greater the likelihood it may affect performance. 
Chimney height may need to be increased by 2  - 3% per 

each 1000 feet above sea level.  It is not recommended to 

use offsets or elbows at altitudes above 4000 feet above sea 

level or when there are other factors that affect flue draft.

WARNING

Asphyxiation Risk.

•  DO NOT CONNECT THIS Appliance TO A CHIM

-

NEY FLUE SERVICING ANOTHER APPLIANCE.

•  DO NOT CONNECT TO ANY AIR DISTRIBUTION 

DUCT OR SYSTEM.

May allow flue gases to enter the house.

Improper installation, adjustment, alteration, service or main-

tenance can cause injury or property damage. Refer to the 

owner’s information manual provided with this appliance. For 

assistance or additional information consult a qualified installer, 

service agency or your dealer.

WARNING

Fire Risk

.

Inspection of Chimney:

•    Chimney must be in good condition.
•    Meets minimum standard of NFPA 211

•  Factory-built chimney must be 6 inch (152mm) UL103 HT.

WARNING

Chimney

:

The chimney can be new or existing, masonry or prefabricated 

and must meet the following minimum requirements and as 

specified in Section 4F.

Содержание 57ST-ACC-B

Страница 1: ...er fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause a ho...

Страница 2: ...cations 3 E Non Combustible Materials 3 F Combustible Materials 3 2 Getting Started 4 A Design and Installation Considerations 4 B Fire Safety 4 C Negative Pressure 5 D Tools And Supplies Needed 5 E I...

Страница 3: ...ly grounded to the frame of the mobile home with 8 copper ground wire Outside Air Kit part OAK ACC must be installed in a mobile home installation Improper installation adjustment alteration service o...

Страница 4: ...nstallation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building fire officials or authori ties having jurisdiction about restrictions inst...

Страница 5: ...ustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways o...

Страница 6: ...o the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the...

Страница 7: ...11 16 686mm 9 1 8 232mm 19 1 4 489mm 24 610mm 5700 Step Top Pedestal Model 14 15 16 380mm 9 3 16 233mm 17 1 8 435mm 21 1 16 535mm 26 1 16 662mm 33 7 8 861mm Figure 7 3 Front View 5700 Step Top Queen A...

Страница 8: ...016 5700 STEP TOP ACC A Appliance Dimensions continued NOTE Flue Collar size is 6 inch 152mm diameter ID Figure 8 2 Side View Figure 8 1 Front View 5700 Step Top Traditional Leg Model 33 7 8 860mm 24...

Страница 9: ...imilar floor protection must be provided 18 inches 457mm in front and 8 inches 203mm from the sides and rear of the appliance Figure 9 2 See exception EXCEPTION Non combustible floor protector must ex...

Страница 10: ...1 45 1143 18 457 DOUBLE WALL PIPE 12 1 2 318 7 1 2 191 15 381 2 51 15 381 45 1143 13 330 INSTALLATION 90 DEGREE ELBOW OFF TOP OF STOVE THROUGH BACKWALL SINGLE WALL PIPE 12 1 2 318 7 1 2 191 28 1 2 724...

Страница 11: ...warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of...

Страница 12: ...vel and or when there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Fig 12...

Страница 13: ...r ULC S629M Must use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for installatio...

Страница 14: ...commended by chimney connector manu facturer Figure 14 2 Instructions 1 Open inside wall at proper height for the chimney con nector to entry the masonry chimney Figure 14 2 2 Entry hole to masonry ch...

Страница 15: ...Wall Spacer Wall Band Trim Collar Chimney Connector 1 inch 25mm Air Space to Chimney Section Min Clearance 2 inch 51mm Min Chimney Clearance to Wall Spacer and Combustibles 2 inch 51mm Chimney Sectio...

Страница 16: ...6 3 9 Install ARS latch by sliding latch assembly over 2 threaded studs protruding from the bottom on the left hand side of the appliance Secure by using two nuts use 7 16 socket wrench Figure 17 1 on...

Страница 17: ...pedestal base 3 Install ARS access cover inside of ARS Channel that is located inside the firebox Figure 18 2 NOTE If installing a floor installation of an outside air kit on a Step Top model with a p...

Страница 18: ...side of firebox and set aside 2 Remove the 3 bricks in the front most part of the firebox Figure 16 1 on page 16 3 Lay appliance on its back on a protective pad or pallet Figure 16 2 on page 16 4 Remo...

Страница 19: ...s head screwdriver Start bottom two bolts through ash drawer leg mount and into the bottom of the appliance Figure 19 1 Align top holes and repeat secure all four bolts 4 Install legs onto mounting br...

Страница 20: ...right and a left of the leg brackets Figure 20 1 5 Install six screws to the bottom of the leg brackets Figure 20 1 6 Attach legs onto leg brackets and secure with bolts and wash ers 7 Carefully stan...

Страница 21: ...ew driver Silicone sealant Drills and saws necessary for cutting holes through the wall or flooring in your home Installation Instructions 1 Remove all materials from packing box 2 Floor Rear Installa...

Страница 22: ...d blow gently but should not stop G Blower Optional Tools Required 2 Phillips head screwdriver 1 Locate bolts supplied with the blower 2 Align holes in mounting flange of blower with bolt holes in app...

Страница 23: ...must be connected to a 6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when in...

Страница 24: ...24 7038 206F September 27 2016 5700 STEP TOP ACC 7 Reference Materials Date of Service Performed By Description of Service...

Страница 25: ...September 27 2016 7038 206F 25 5700 STEP TOP ACC Date of Service Performed By Description of Service...

Страница 26: ...26 7038 206F September 27 2016 5700 STEP TOP ACC Date of Service Performed By Description of Service...

Страница 27: ...Head Philips 8 32 X 3 8 Pkg of 40 225 0500 40 Y Screw Sheet Metal 8 X 1 2 S Grip Pkg of 40 12460 40 Y Washer 1 4 Sae Pkg of 24 28758 24 Y Washer 3 8 Sae Pkg of 3 832 0990 Y Fiber baffle Ceramic blank...

Страница 28: ...peration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This pro...

Отзывы: