background image

1

02/23

7037-807C

Owner’s Manual

Operation & Care

INSTALLER: Leave this manual with party responsible for use and operation. 

OWNER: Retain this manual for future reference. 

Contact your dealer with question on installation, operation, or service. 

R

4300 STEP TOP

AUSTRALIA

WOOD APPLIANCE

AUTOMATIC COMBUSTION 

CONTROL (ACC)

MODEL:

43ST-ACC-AU

•  Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

•  Do not over fire - If appliance or chimney connector 

glows,  you  are  over  firing.  Over  firing  will  void 

your warranty.

•  Comply with all minimum clearances to combustibles 

as specified.

Failure to comply may cause house fire.

If the information in these instructions is 

not  followed  exactly,  a  fire  could  result 

causing property damage, personal 

injury, or death.

 

WARNING

WARNING

HOT SURFACES!

Glass and other surfaces are hot during 

operation AND cool down.

Hot glass and appliance will cause burns.

•  Do not touch glass until it is cooled

•  Use leather gloves when reloading fuel

•  NEVER allow children to touch glass

•  Keep children away

•  CAREFULLY  SUPERVISE  children  in  same  room 

as appliance.

•  Alert  children  and  adults  to  hazards  of 

high temperatures

•  High  temperatures  may  ignite  clothing  or  other 

flammable materials.

•  Keep  clothing,  furniture,  draperies  and  other 

flammable materials away.

Fire Risk.

For use with solid wood fuel only.
Other  fuels  may  over  fire  and  generate 

poisonous gases (i.e. carbon monoxide).

WARNING

Содержание 43ST-ACC-AU

Страница 1: ...ed Failure to comply may cause house fire If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death WARNING WARNING HOT SURF...

Страница 2: ...AGE PARTICULATE EMISSION FACTOR WHEN TESTED IN ACCORDANCE WITH AS NZS 4013 0 4 g kg 1 0 g kg MAXIMUM AVERAGE HEAT OUTPUT 10 kW 12 kW APPROVED FUEL BURN ONLY WOOD WITH A MOISTURE CONTENT LESS THEN 25 d...

Страница 3: ...eneral Maintenance 17 D Correct Baffle Blanket Placement 19 4 Troubleshooting Guide 20 5 Service Part Replacement 21 A Glass Replacement Door Assembly 21 B Firebrick Replacement 21 C Door Handle Assem...

Страница 4: ...ective in materials or workmanship during the applicable warranty period HHT will at its option repair or replace the covered components HHT at its own discretion may fully discharge all of its obliga...

Страница 5: ...d is not covered under warranty Damage to printed plated or enamelled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated...

Страница 6: ...d to improper chimney or venting installation HOW TO CLAIM To make a claim against this warranty contact your local distributor during regular business hours See addresses below for a dealer nearest y...

Страница 7: ...D KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The applian...

Страница 8: ...Size 6 inches Firebox Size 2 3 cubic feet Recommended Wood Length 18 inches Fuel Orientation Front to Back Approved Fuel Softwood and Hardwood only with a Moisture content less than 25 dry basis Impr...

Страница 9: ...r wood sizzles in the fire even though the surface is dry it may not be fully cured Splitting wood before it is stored reduces drying time Wood should be stacked so that both ends of each piece are ex...

Страница 10: ...amount of heat needed to dry and rekindle the next load of wood It is best to open the Burn Rate Air and Start Up Air Controls before reloading This livens up the coal bed and reduces excessive emissi...

Страница 11: ...teAir Control spring handle up to high position for 5 minutes Then activate the ACC timer system by pushing the knob all the back toward the appliance to HI then pull forwards towards the front of the...

Страница 12: ...sticks of kindling on top of the paper 6 Make sure that no matches or other combustibles are in the immediate area of the appliance Be sure the room is adequately ventilated and the flue unobstructed...

Страница 13: ...NOT burn treated wood or wood with salt driftwood May generate carbon monoxide if burn material other than wood May result in illness or possible death WARNING When burning your first fire you will ex...

Страница 14: ...o find a dealer ISSUES SOLUTIONS Odor from appliance When first operated this appliance may release an odor for the first several hours This is caused by the curing of the paint and the burning off of...

Страница 15: ...vent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or after every 25 loads of wood Ashes must be cool before you can dispose of the ashes in a non combustible container Firebrick is...

Страница 16: ...apidly move the ARS latch handle up and down to help remove any ash from the door Use a small brush to clean off the top of the door if any ash remains Be sure to replace the cap before operating the...

Страница 17: ...e The chimney connector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it sho...

Страница 18: ...leaner left on during the next firing can permanently stain the glass and damage the finish on metal surfaces A portion of the combustion air entering the firebox is deflected down over the inside of...

Страница 19: ...CORRECT POSITION Ceramic Blanket and Baffle Board MUST be in contact with the back of the firebox and even with each other in the front WARNING Fire Risk Firebox damage due to improper baffle placeme...

Страница 20: ...uate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals...

Страница 21: ...is out and the appliance is cool to the touch 2 Protect a table or counter top with padding or towels Protect your hands and wear gloves to prevent injury 3 Remove the door with the broken glass by l...

Страница 22: ...install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 22 3 5 To re install the ceramic blanket it is easier t...

Страница 23: ...hannel assembly a clearance of 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the appliance will have to be disconn...

Страница 24: ...24 02 23 7037 807C A Service and Maintenance Log Date of Service Performed By Description of Service 6 6 Reference Materials...

Страница 25: ...25 02 23 7037 807C Date of Service Performed By Description of Service...

Страница 26: ...Parts List Service Parts R 43ST ACC AU Beginning Manufacturing Date May 2021 Ending Manufacturing Date Active Step Top Model Wood Stove Part number list on following page 02 23 1 2 3 4 5 6 7 8 9 10 1...

Страница 27: ...4 5 x 1 25 Qty 11 Reg 832 0550 4 2 Brick 6 x 4 5 x 1 25 Qty 4 Reg SRV7128 002 4 3 Brick 4 5 x 4 5 x 1 25 Qty 2 Reg SRV7128 001 4 4 Brick 9 x 4 5 x 1 25 with angle Qty 1 Reg SRV7128 806 4 5 Brick 9 x 3...

Страница 28: ...t SRV7037 010 18 Tube Channel Top Access Cover SRV7033 237 19 Tube Channel Assembly Manifold Tubes SRV7033 023 Y Gasket Manifold Pkg of 4 7038 168 4 Y 20 1 Burn Rate Control Assembly SRV7037 004 Y 20...

Страница 29: ...KIT NL 21 1 Ash Pan Assembly SRV7033 008 21 2 Legs Queen Anne Black 831 1240 Nickel LEGS QANL 21 3 Ash Pan Leg ARS Ash Pan Removal System SRV7033 050 21 4 Leg Mount Kit SRV7037 132 Component Pack Leg...

Страница 30: ...Door Assembly Required to Complete Option Black DR 31 43BK FH Y Nickel DR 31 43NL FH Y 23 1 Hinge Pins 1 2 Black 7000 606 2 Y Nickel SRV430 5320 23 2 Rope Door 3 4 x 84 Field cut to Size 7 Ft Length...

Страница 31: ...ption DR 31RCT Y 25 1 Hinge Pins 1 2 Black 7000 606 2 Y 25 2 Glass Assembly SRV7044 027 Y Gasket Glass Tape Field cut to Size 5 Ft Length 832 0460 Y 25 3 Glass Frame Set Qty of 2 SRV7044 191 25 4 Scre...

Страница 32: ...39 Outside Air Shield SRV33271 Y Upgrade Door Nickel Handles Hinge Pins Logo Nickel UK DRNL Logo Quadra Fire Pkg of 10 7000 649 10 Cast Legs Black Set of 4 TRAD LEG BK FASTENERS Avk Rivnut Repair Kit...

Страница 33: ...33 02 23 7037 807C...

Страница 34: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: