A. Appliance Safety Certification
B. Appliance Emissions Certification
C. BTU & Efficiency Specifications
Model:
43M-ACC-C & 43ST-ACC-C
Laboratory:
OMNI Test Laboratories, Inc.
Report Number:
0061WS067S
Type:
Listed Room Appliance, Solid
Fuel Type
Standard:
UL1482-11 (R2015), ULC S627-00
and (UM) 84-HUD,
Mobile Home Approved.
Model:
43M-ACC-C & 43ST-ACC-C
Laboratory:
PFS-TECO
Report Number:
19-538
Standard:
Method 28 and 5G, and
ASTM E2515
Can be found at:
www.quadrafire.com/about-us/epa-certification
This wood appliance needs periodic inspection and repair for proper operation. Consult the owner’s manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner’s manual.
NOTE:
This installation must conform with local codes. In the absence of local codes you must comply with
(UM) 84-
HUD and NFPA211 in the U.S.A. and CAN/CSA-B365 Installation Codes in Canada
.
1
Important Safety Information
EPA Certification
Number:
Number: N/A
EPA Certified
Emissions:
1.6 grams per hour
*LHV Tested Efficiency:
80.2%
**HHV Tested Efficiency:
74.2%
***EPA BTU Output:
13,200 to 36,800 / hr.
****Peak BTU/Hour
Output:
61,700
Vent Size:
6 inches
Firebox Size:
2.26 cubic feet
Recommended Log
Length
18 inches
Fuel:
Seasoned Cordwood
(20% moisture)
* Weighted average LHV (Low Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. LHV assumes the moisture
is already in a vapor state so there is no loss in energy to
vaporize.
** Weighted average HHV (High Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. HHV includes the energy
required to vaporize the water in the fuel.
*** A range of BTU outputs calculated using HHV
Efficiency and the burn rates from the EPA tests, using
Douglas Fir dimensional lumber.
**** A peak BTU out of the appliance calculated using
the maximum first hour burn rate from the High EPA Test
and BTU content of seasoned cordwood (8600) times
the efficiency.
The 43M-ACC-C & 43ST-ACC-C
are Certified to comply with
2020 crib wood particulate
emission standards.