September 1, 2008
7033-277F
Page 1
3100 Wood Stove Series (ACC)
R
Must extend 2 in. (51mm) beyond
each side of pipe (shaded area)
NOTE: •
Illustrations and photos reflect typical installations and are FOR DESIGN PURPOSES ONLY
.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design preference
•
Hearth & Home Technologies reserves the right to alter its products.
16 in. from glass
8 in.
Fuel loading door
4-3/4 in.
3-1/4 in
.
1-5/8 in.
minimum
9-5/8 in.
minimum
20mm (8 in.)
20mm
(8 in.)
20mm
(8 in.)
457mm (18 in.)
1254mm
(49-/8 in.)
minimum
1041mm (41 in.)
minimum
USA required
Canada recommended
Figure 13.3
Figure 13.1
Figure 13.2
Figure 13.4
Step-Top Uni-Body Model
For the Step Top Pedestal Model In US installations,
it is
necessary to install a floor protector of a minimum of /8 inch
(9.5mm) thick metal clad millboard or equivalent a minimum of
16 inches (406mm) in front of glass and 8 inches (20mm)
to both sides of the fuel loading door. Open the door and
measure 8 inches (20mm) from the side edge of the open
-
ing in the face of the appliance. *
See page 12 for Canadian
clearances and horizontal venting exception.
For the Step Top Leg Model In US installations,
it is nec
-
essary to install a floor protector of a minimum thickness of
1-1/4 inch (2mm) or 1/2 inch of “k” value of 0.84 thick metal
clad millboard or equivalent a minimum of 16 inches (406mm)
in front of glass and 8 inches (20mm) to both sides of the
fuel loading door. Open the door and measure 8 inches
(20mm) from the side edge of the opening in the face of
the appliance. *
See page 12 for Canadian clearances and
horizontal venting exception.
48-9/16 in.
31-5/8 in
.
38-15/16 in
.
27-5/16 in
.
3-1/16 in
.
29-1/4 in.
135°
optional
coverage
USA
USA
CANADA