background image

July 7, 2011

7033-277I

Page  21

3100 Wood Stove Series (ACC)

R

7

Appliance Set Up

Figure 21.3

   

Do 

NOT

 operate before fully assembling components.

Burning your stove without a pedestal or leg kit
attached:

• 

Will void your warranty.

• 

May result in property damage or personal injury.

WARNING

NOTE:    The  Ash  Removal  System,  must  be 

installed fi rst before installing the pedestal.

A.  Pedestal Assembly and Ash Removal 

System (ARS) Installation for Step Top 
Uni-body

Door handle must be
in open position to
tighten set screw

Set Screw

(align with flat

side of rod)

Ash Door Rod shown
in installed position

Remove 2 bricks for

 installation and then re-install

ARS Cover

Glossy side of 
Gasket 
against firebox 
bottom

Start sliding rod at 
an angle into slot, 
slide handle over rod 
and then finish 
pushing through slot.

Ash Door 
Assembly

Magnet

Lay stove flat on 
protective padding or 
pallet

Door Handle

Figure 21.1

Figure 21.2

Included  in  Kit

:    Door  assembly,  door  handle  &  magnet, 

ash drawer, fastener package. A cover plate that is required 
for 

a fl oor outside air installation on a pedestal model is also 

included,  If not needed, discard.

Tools  Required:

    Phillips  head  screwdriver,  7/16  socket 

wrench, 3/32 and 5/36 Allen wrench.

Begin installing the ARS System.

1.  Remove 2 front bricks as shown in 

Figure 21.1.

  

2.  Lay body of stove on its back on a protective pad or pallet.

3.  Remove  the  2  nuts  and  2  bolts  holding  the  channel  in 

place  and  set  the  channel  aside.    Discard  the  2  nuts. 
Install the gasket over the 8 protruding screws.

The glossy side of the gasket needs to go against the 

fi rebox 

bottom.  

It  is  important  the  gasket  is  not  put  on  upside 
down as it could compromise its sealing capa-
bilities.

  

Figure 21.2.

4.  Install ash door assembly by sliding the rod at an angle 

into  the  slot  on  the  left  side.    As  the  rod  starts  passing 
through the slot, slide the handle over the rod and then 
fi nish pushing the rod through the slot.  

Slide the ash door over the 8 screws protruding from the 
bottom of the stove.  Secure with nuts and washers pro-
vided. 

 Figure 21.2.

5.  Re-install handle using a 3/32 Allen wrench to tighten the 

set screw in the door handle.  The set screw needs to be 
snug.   

Figure 21.3.

6.  Install  magnet  using  a  Phillips  head  screw  driver.    This 

magnet  will  hold  the  door  handle  in  an  open  position 
which in turn holds the ash door open so ashes can be 
brushed into the ash drawer.  

Figure 21.2.

Содержание 3100 Millennium

Страница 1: ... fuel only Other fuels may overfire and generate poisonous gases i e carbon monoxide Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies recommends NFI certified professionals or technicians supervised by an NFI certified professional WARNING Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch gla...

Страница 2: ...UMÉRO DE SÉRIE A B C D E F E F G H G A B C D R 16 from glass 8 USA Fuel loading door Millennium Step Top 31 5 8 Min Millennium Step Top 39 5 8 minimum 7033 278 CANADA 203mm 8 203mm 8 203mm 8 457mm 18 Millennium 1280mm 50 3 8 minimum 1040mm 41 minimum CHAUD LORS DE L OPÉRATION NE PAS TOUCHER GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L ESPACE DÉSIGNÉ DE L INSTALLATION LE CONTACT PEUT CAUSER DES BR...

Страница 3: ...n 8 Operating Instructions A Over Firing Your Appliance 25 B Wood Selection Storage 25 C Burning Process 25 26 D Automatic Combustion Control ACC 26 E Air Controls 26 27 F Burn Rates Operating Efficiency 27 G Building A Fire 28 H Baffle Blanket Placement 29 I Blower Operating Instructions 30 J Opacity Smoke 30 K Frequently Asked Questions 30 Section 9 Maintaining Servicing Appliance A Quick Refere...

Страница 4: ...eet Max Wood Length 18 inches Fuel Cord Wood Shipping Weight 325 lbs Model 3100 Millennium Step Top Uni Body ACC Laboratory OMNI Test Laboratories Inc Report No Date 061 S 66 6 Type Listed Room Heater Solid Fuel Type Standard UL1482 and ULC S627 00 and UM 84 HUD Mobile Home Approved NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specific...

Страница 5: ...g appliance and close to the sleeping areas Follow the smoke detector manufacturer s placement and installation instructions and be sure to maintain regularly 2 A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers 3 A practiced evacuation plan consisting of at least two escape routes 4 A plan to deal with a chimney fire as follows In the event ...

Страница 6: ...include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water heaters and other combustion appliances Clothes dryers Location of return air vents to furnace or air condi tioning Imbalances of HVAC air handling system Upper level air leaks Recessed lighting Attic hatch opening Duct leaks To minimize the affects of negative air pressure the following must be consid...

Страница 7: ...ce after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations F Tools And Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Reciprocating saw Pliers Hammer Phillips Head Screwdriver Flat Blade Screwdriver Plumb Line Level Tape Measure Framing Material Hi Temp...

Страница 8: ...ermination Cap Outside Air Rear Vent Spark Arrestor Cap Floor Protector Chimney Connector Ceiling Support Listed Chimney Listed Termination Cap Storm Collar Flashing Figure 8 3 Interior Prefabricated Chimney Figure 8 2 Exterior Prefabricated Chimney Figure 8 1 Masonry Chimney H Typical Stove Systems Stove system with masonry chimney consists of Stove Chimney Connector stove pipe Thimble Masonry Ch...

Страница 9: ...6mm 11 1 2 in 292mm 20 3 4 in 527mm C L 4 1 2 in 108mm Outside Air Connection C L A Appliance Dimensions Figure 9 1 Front View Figure 9 2 Side View NOTE Flue Collar size is 6 inch 152mm diameter ID 14 15 16 in 373mm 25 in 635mm 9 15 16 in 237mm 12 1 2 in 318mm 30 in 762mm 15 1 16 in 383mm 10 15 16 in 271mm 18 15 16 in 475mm C L Millennium Model ...

Страница 10: ...ep Top Leg Model 23 7 8 in 606mm 33 1 8 in 841mm 15 1 16 in 383mm 19 1 16 in 484mm 10 15 16 in 278mm 14 15 16 in 379mm 3 11 16 in 94mm 21 1 8 in 537mm 10 3 8 in 264mm 6 11 16 in 170mm 3 1 2 in 89mm C L 34 1 4 in 870mm 25 in 635mm 12 1 2 in 318mm 9 5 16 in 237mm C L 18 in 457mm 26 11 16 in 678mm 24 5 16 in 618mm 15 3 8 in 391mm 11 1 2 in 292mm 16 in 406mm 20 3 4 in 527mm ...

Страница 11: ...tove Through Backwall SINGLE WALL PIPE Flat Top Model 12 305 8 5 216 22 559 13 330 8 203 17 432 48 1220 12 305 Step Top Model 10 254 6 152 20 5 521 11 279 5 5 140 14 5 368 48 1220 12 305 DOUBLE WALL PIPE Flat Top Model 8 203 4 5 114 17 5 445 8 5 216 6 5 165 15 5 394 48 1220 9 229 Step Top Model 10 254 6 152 20 5 521 11 279 4 102 13 330 48 1220 9 229 INSTALLATION ALCOVE Six inch 6 152mm diameter li...

Страница 12: ...of the open ing in the face of the appliance See exception 16 in from glass 8 in Fuel loading door 4 7 8 in 3 1 8 in 31 5 8 in minimum 39 5 8 in minimum Must extend 2 in 51mm beyond each side of pipe shaded area 203mm 8 in 203mm 8 in 203mm 8 in 457mm 18 in 1260mm 49 5 8 in minimum 1041mm 41 in minimum In Canada similar floor protection must be provided 18 inches 457mm in front and 8 inches 203mm f...

Страница 13: ...thick metal clad millboard or equivalent a minimum of 16 inches 406mm in front of glass and 8 inches 203mm to both sides of the fuel loading door Open the door and measure 8 inches 203mm from the side edge of the opening in the face of the appliance See page 12 for Canadian clearances and horizontal venting exception For the Step Top Leg Model In US installations it is neces sary to install a floo...

Страница 14: ...ghtly sealed doors and windows an outside air source is needed An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex Adapter Termination Cap For Floor Installa tions Remove Circular Knock Out in Base of Pedestal WARNING Do not draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Close proximity to exhaust vents or chimneys Fume...

Страница 15: ...nder the bottom left rear corner as shown in Figure 15 1 See page 30 for detailed operating instructions for the blower and snap disc Shock Risk Do NOT remove grounding prong from plug Plug directly into properly grounded 3 prong receptacle Route cord away from appliance Do NOT route cord under or in front of appliance CAUTION Figure 15 1 MANUAL Over rides the Snap Disc AUTO Fan will turn ON OFF A...

Страница 16: ...teel black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connector passes to the chimney It is intended to keep the walls from igniting Site constructed thimbles must meet NFPA 211 Standards Prefabricated must be suitable for use with selected chimney and meet ...

Страница 17: ...ing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 17 1 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wall opening The spacer should be on the chimney side 6 Insert the section of the solid insulated chimney into the outer wall of the masonry chimney 7 Tightly secure the length of the solid...

Страница 18: ...ors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Stove Secure pipe sections with a minimum of 3 screws Figure 18 2 Chimney Connector Stove Pipe WARNING DO NOT CONNECT THIS UNIT TO A CHIM NEY FLUE SERVICING ANOTHER APPLI ANCE DO NOT CONNECT TO ANY AIR DISTRI BUTION DUCT OR SYSTEM May allow flue gases to enter the house Asphyxiation Risk Improper i...

Страница 19: ...roof within 10 feet 305cm Must be located away from trees or other struc tures These are safety requirements and are not meant to assure proper flue draft Figure 19 1 E 2 10 3 Rule Figure 19 2 NOTE Chimney performance may vary Trees buildings roof lines and wind conditions affect performance Chimney height may need adjustment if smoking or overdraft occurs 3 ft 91cm Minimum Less than 10 ft 305cm 2...

Страница 20: ...nnector UL103 HT chimney and terminal cap with spark arrestor Never use a single wall connector stove pipe in a mobile home installation Use only double wall connector pipe Dura Vent DVL Selkirk metalbestos DS or Security DL double wall connector or any listed double wall connector pipe 5 In Canada this appliance must be connected to a 6 inch 152mm factory built chimney conforming to CAN ULC 629M ...

Страница 21: ...included If not needed discard Tools Required Phillips head screwdriver 7 16 socket wrench 3 32 and 5 36 Allen wrench Begin installing the ARS System 1 Remove 2 front bricks as shown in Figure 21 1 2 Lay body of stove on its back on a protective pad or pallet 3 Remove the 2 nuts and 2 bolts holding the channel in place and set the channel aside Discard the 2 nuts Install the gasket over the 8 prot...

Страница 22: ...arefully stand stove up and place in desired location 5 Slip wooden decorative strips onto pedestal edges Finishing the ARS Installation 1 Re install the ARS channel that was removed in Step 3 on page one and secure with 2 bolts previously removed Set the cover into the ARS channel Replace the 2 front cut bricks Figure 22 2 2 Install the ash drawer 3 Check to make sure baffle boards and ceramic bl...

Страница 23: ...crews are located in the component pack Leave the bottom 2 screws loose so you can slide the ash pan assembly bottom slots over the screw heads This al lows the weight of the ash pan to rest on the screws while you are attaching the top 2 screws Once the ash pan is attached tighten all screws Figure 23 2 3 Loosely assemble bolts into the corner of the mounting brackets for leg attachment Figure 23...

Страница 24: ...tighten lock nut Door handle needs to move smoothly E Calculating Alternate Floor Protection Material Thermal Conductivity k value The k value indicates the amount of heat in BTU s that will flow in 1 hour through 1 square foot of a uniform material 1 inch thick for each degree F of temperature difference from one side of the material to the other The LOWER the k factor means less heat is being co...

Страница 25: ...t of wet unseasoned wood resulting in wasted heat Do not over fire Over firing may ignite creosote or will damage the stove and chimney To prevent over firing your stove DO NOT Use flammable liquids Overload with wood Burn trash or large amounts of scrap lumber Permit too much air to the fire WARNING Fire Risk Symptoms of over firing may include one or more of the following Chimney connector or ap...

Страница 26: ...s function is performed by sliding the con trol all the way back until it stops at the HI indicator on the label and then pulling forward to the front of the stove until it stops This activates the ACC system and opens the front air channel and allows air to enter the front of the stove for approximately 25 minutes The front air channel gradually shuts down until it is completely closed at the end...

Страница 27: ...is air is regulated by the Burn RateAir Control There are four settings High Medium High Medium Low and Low When the control is raised all the way up it is on the High setting and when pushed all the down it is on the Low setting Figure 27 1 NOTE These are approximate settings and will vary with type of wood or chimney draft Due to altitude and other environmental circumstances this operational in...

Страница 28: ...02mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7 Set the Burn Rate Air Control and activate the timer system ACC 8 When ready to reload It is best to fully open both the Burn Rate Air and Start up Air Controls before reload ing This livens up the co...

Страница 29: ...e to improper baffle place ment is not covered by warranty Operate the wood burning appliance with the baffle in the correct position only Not doing so could result in Reduced efficiency Overheating the chimney Overheating the rear of the firebox Poor performance WARNING Fire Risk Ensure correct baffle placement and replace baffle com ponents if damaged or missing Ceramic Blanket and Baffle Board ...

Страница 30: ...page 15 I Blower Operating Instructions WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt driftwood May generate carbon monooxide if burn material other than wood May result in illness or possible death Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance WARN...

Страница 31: ...ent pipe blockage poor draft and chimney fires Always burn dry wood to help prevent cap blockage and creosote build up Keeping the door and glass gasket in good shape will maintain good burn times on a low burn setting Check the glass frame for loose screws to prevent air leakage Check the door latch for proper adjustment This is very important especially after the door rope has formed to the stov...

Страница 32: ...that before each heating season the entire system be professionally inspected cleaned and repaired if necessary a The stove and ashes must be completely cooled down before using the Ash Removal System Reach down and locate the ash removal door handle under the left side of the stove in the center Squeeze the handle and push all the way back Amagnet will hold the handle in place which in turn holds...

Страница 33: ...ally available oven cleaner After using an oven cleaner it is advisable to remove any residue with a glass cleaner or soap and water Oven cleaner left on during the next firing can permanently stain the glass and damage the finish on plated metal surfaces A portion of the combustion air entering the firebox is deflected down over the inside of the door glass This air flow washes the glass helping ...

Страница 34: ...ch retainer just a few turns until each is secured Check again for centering of glass in door frame Continue to tighten each retainer alternately a few turns at a time until the glass is secure DO NOT OVERTIGHTEN 9 Replace the door on the appliance Quadra Fire stoves are equipped with ceramic super heat resistant glass which can only be broken by impact or misuse Do not slam stove door or impact t...

Страница 35: ... brick under clips on side of firebox and push the bottom of the brick until it is flush with the side of the appliance D Firebrick Replacement Use Part 832 0550 when ordering individual brick Provide brick dimension or copy this page mark the desired brick and take it to your authorized dealer No Brick Size Qty 1 9 x 4 1 2 x 1 1 4 12 2 6 x 4 1 2 4 3 9 x 4 1 2 with angle see drawing 1 4 9 x 3 with...

Страница 36: ... top of baffle board open up and flatten and smooth out the blanket Re check the baffle board for correct positioning Figure 36 2 Figure 36 1 Baffle Figure 36 2 Ceramic Blanket F Snap Disc Replacement Magnet Spade Connectors Snap Disc Figure 36 3 1 Locate the snap disc bracket assembly at the bottom left rear corner of the stove Figure 36 3 2 A magnet holds the bracket to the stove Pull the bracke...

Страница 37: ...ube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 3 Make sure tube channel assembly is flush against the side of the stove and secure with channel nuts 4 Re install channel cover and side shield Channel Access Cover Channel Nuts 2 Side Panel Tube Channel Assembly Channel Cover Screws 4 Tube Channel ...

Страница 38: ... appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to wood fuel sec tion Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to starting fire section Flue blockage such as birds nests or leaves in termination cap Have chimney inspected for creosote and cleaned by a certified chimney sweep Down draft or n...

Страница 39: ... Figure 39 1 Service Parts 04 11 R Step Top Wood Stove 31ST ACC Advanced Combustion Control 3100 ACC Step Top Part number list on following page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Beginning Manufacturing Date Sept 2006 Ending Manufacturing Date Active ...

Страница 40: ...Req 4 4 Brick 4 1 2 x 4 1 2 x 1 1 4 Qty 2 Req 4 5 Brick 9 x 3 x 1 1 4 w angle see diagram Qty 1 Req Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 5 Tube Support Rack 7033 148 6 Brick Retainer 7033 149 7 Ceramic Fiber Blanket 1 2 Thick 19 W x 13 3 4 H 832 3390 Y 8 Baffle Board 9 1 2 in W x 13 3 4 in H Pkg of 2 SRV7033 209 Y 9 Rear Channel Assembly 7033 002 Y 10 Access Cover SRV7038 196 11 Panel A...

Страница 41: ...229 0631 14 9 Timer Arm Assembly 7033 034 Y 14 10 Timer Only Replacement Assembly SRV480 1940 Y 15 1 Ash Pan Assembly 7033 008 Ash Pan Leg ARS 7033 050 15 2 Legs Queen Anne Black 831 1240 Gold 831 1250 Nickel LEGS QANL 15 3 Leg Mount Brackets Pkg of 2 SRV7033 183 Pedestal For Air Control PED 3143 16 1 Pedestal Assembly 7033 013 16 2 Strip Oak Trim 832 0560 Door Assembly ARS SRV7033 015 Y Ash Pan D...

Страница 42: ...MBER 17 1 Door Assembly Black 832 1092 Gold Trim 832 1912 Nickel Trim DR 31 43NL 17 2 Hinge Pins 1 2 Gold Pkg of 2 832 0250 Nickel Qty 2 req 430 5320 17 3 Door Handle Assembly 832 0540 Y 17 4 Door Handle Only 430 1131 17 5 Spring Handle Door 1 2 Gold 832 0620 Y Nickel 250 8330 Y 17 6 Trim Ring Door Gold 430 2682 Nickel 430 5340 17 7 Door Glass Assembly 15 1 2 in W x 13 3 8 in H 7000 012 Y 17 8 p 4...

Страница 43: ...Warranty Card Spring Handles in Door Assembly 7033 043 Component Pack Includes Touch Up Paint Spring Handles 1 1 2 and 2 1 4 Trimount Plug Owners Manual and Warranty Card Black Gold Trim 7033 027 Nickel Trim 7033 029 Paint Touch Up 812 0910 Plug Trimount 250 Pkg of 24 229 0880 24 Y Gasket Manifold Pkg of 4 7038 168 4 Y ACCESSORIES Blower Assembly BK ACC Blower Control Box w Switch SRV7000 194 Y Co...

Страница 44: ...anced Combustion Control ACC 3100 ACC Millennium Part number list on following page 31M ACC MBK 7 06 Active 31M ACC GT 7 06 10 06 31M ACC NT 7 06 10 06 Beginning Manufacturing Date July 2006 Ending Manufacturing Date Active 1 2 3 4 5 6 7 8 9 10 11 14 13 12 Exploded Drawing ...

Страница 45: ...3 3 4 H 832 3390 Y 9 Baffle Board 9 1 2 in W x 13 3 4 in H Pkg of 2 SRV7033 209 Y 10 Brick Assembly Complete Set Pkg of 18 SRV7033 006 10 1 Brick 9 x 4 1 2 x 1 1 4 Qty 12 Req 10 2 Brick 6 x 4 1 2 x 1 1 4 Qty 4 Req 10 3 Brick 9 x 4 1 2 x 1 1 4 w angles see diagram Qty 1 Req 10 4 Brick 9 x 3 x 1 1 4 w angle see diagram Qty 1 Req Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 11 Panel Assembly Side ...

Страница 46: ...5 Rear Air Control Arm Assembly 7033 035 Y 14 6 Start Up Control Knob 7000 343 14 7 Air Control Rod Guide 7033 210 14 8 Latch Magnet For Air Control 229 0631 14 9 Timer Arm Assembly 7033 034 Y 14 10 Timer Only Replacement Assembly SRV480 1940 Y 15 1 Pedestal Riser 7033 207 15 2 Pedestal Base 7033 163 15 3 Strip Oak Trim Pkg of 2 832 0560 16 Baffle Protection channel SRV7033 298 Additional service ...

Страница 47: ...13 Y 17 5 Trim Ring Door Gold 430 2682 Nickel 430 5340 17 6 Door Glass Assembly 15 1 2 in W x 13 3 8 in H 7000 012 Y 17 7 Glass Frame Set 4 Pieces 832 0350 17 8 Cam Latch 430 1141 17 9 Key Cam Latch 430 1151 17 10 Nut Locking Door Handle Pkg of 24 226 0100 24 Y Component Pack Includes Spring Handles 1 1 2 2 1 4 2 Hinge Pins Quadra Fire Logo Gold Trim Doors 436 5350 Nickel Trim Doors 436 5360 Gaske...

Страница 48: ... 1 4 Trimount Plug Owners Manual and Warranty Card Black Gold Trim 7033 027 Nickel Trim 7033 029 Paint Touch Up 812 0910 Plug Trimount 250 Pkg of 24 229 0880 24 Y Door Handle Assembly 832 0540 Y Upgrade Door Nickel UK DRNL Gasket Manifold Pkg of 4 7038 168 4 Y ACCESSORIES Blower Assembly BK ACC Blower Control Box w Switch SRV7000 194 Y Component Pack 7033 051 Snap Disc Bracket Assembly SRV7033 036...

Страница 49: ...July 7 2011 7033 277I Page 49 3100 Wood Stove Series ACC R E Service and Maintenance Log Date of Service Performed By Description of Service ...

Страница 50: ...Page 50 7033 277I July 7 2011 R 3100 Wood Stove Series ACC F Warranty Policy ...

Страница 51: ...July 7 2011 7033 277I Page 51 3100 Wood Stove Series ACC R ...

Страница 52: ...ship purchased from Dealer phone Notes We recommend that you record the following pertinent information for your 3100 WOOD STOVE ACC DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instructions included Leave this manual with party responsible for use and operation Read understand and follow these instructions for safe installation and operation D O N O T D I S C A R D This ...

Отзывы: