background image

Page  4

7037-141D

October 12, 2015

2100 & 4300 Millennium ACC Wood Burner

Draw

ing

 not

 to 

s

c

ale

 

FLOOR PROTECTOR

 

1.QF.1B

 

Quadra-fire 2100 & 4300 Millennium ACC do not require a insulating Floor Protector, as they are tested 

and comply with the minimum Floor Protector requirements of AS/NZS 2918:2001.

 

Note:

 

ŀ

 The minimum Floor Protector sizes are specified in the clearance chart, see Table 1 & 2.

 

ŀ

 A Floor Protector can include ceramic tiles with grouted joints fixed directly onto a wooden floor or a 

sheet of toughened glass, panel steel or any other non combustible material laid directly onto a 

wooden floor.

 

ŀ

 If installed directly onto a concrete slab, the concrete slab can be considered as the floor protector,

 

but must maintain the minimum measurement listed.

 

PARALLEL POSITIONING

 

Fig. 3

A

 

E

 

B

 

F

 

D

 

C

 

G

 

Table 1

DESCRIPTION

 

Pioneer Double Flue Mounted Shield Universal

 

Shall be Fitted

 

With Double Flue

 

Shield Fitted

 

2100

 

4300

 

A 

Min. clearance from firebox to rear wall

 

150

 

200

 

B 

Min. clearance from firebox to side wall

 

550

 

400

 

C 

Min. distance from firebox opening to floor protector front

 

300

 

300

 

D 

Min. distance from firebox to floor protector side

 

76

 

69

 

E 

Min. distance from flue centre to side wall

 

847

 

730

 

F 

Min distance from rear wall to front of floor protector

 

1034

 

1133

 

G 

Width of floor protector

 

746

 

798

 

NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS

 

Clearances may be reduced by provision of an appropriately located heat shield refer to

 

AS/ NZS 2198:2001 3.2.3 Table 3.1

 

DESCRIPTION

Pioneer Double Flue Mounted Shield Universal

Shall be Fitted

With Double Flue Shield Fitted

2100-NZ

2100-AU

4300

A

Min. Clearance from fi rebox to rear wall

150

160

200

B

Min. clearance from fi rebox to side wall

550

280

400

C

Min. distance from fi rebox opening to fl oor protector front

300

300

300

D

Min. distance from fi rebox to fl oor protector side

76

76

69

E

Min. distance from fl ue centre to side wall

847

577

730

F

Min. distance from rear wall to front of fl oor protector

1034

1043

1133

G

Width of fl oor protector

746

746

798

Содержание 21M-ACC-NZ

Страница 1: ...30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 6 7 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitc...

Страница 2: ...mm 271mm 475mm 373mm 660mm 247mm 330mm C L 292mm 527mm 406mm C L L C 729mm 668mm 170mm 108mm Outside Air Connection Fig 2 Quadra Fire 4300 Millenium ACC Wood Burner Dimensions roomfor 14x 875 S N 1 5...

Страница 3: ...ESTEDINACCORDANCEWITHAS NZS4013 MAXIMUMAVERAGEHEATOUTPUTBURNINGSOFTWOOD APPROVEDFUEL WETBACK ALLMODELS MANUFACTUREDBY PERFORMANCEMAYVARYFROMTESTVALUESDEPENDINGONACTUAL OPERATINGCONDITIONS U S ENVIRONM...

Страница 4: ...0 4300 A Min clearance from firebox to rear wall 150 200 B Min clearance from firebox to side wall 550 400 C Min distance from firebox opening to floor protector front 300 300 D Min distance from fire...

Страница 5: ...is being used position now Place the firebox on the floor protector to suit the minimum installation clearances See Fig 3 or 4 2 Seismically restrain the firebox and the floor protector to the floor...

Страница 6: ...t roof penetration see NZ Building Code E2 Acceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition...

Страница 7: ...sing cover is necessary minimum 25mm gap between flue pipe casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing...

Страница 8: ...b Fig 4 6 downward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7...

Страница 9: ...legs from the bracket 5B leaving the entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower ont...

Страница 10: ...ESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RE...

Страница 11: ...October 12 2015 7037 141D Page 11 2100 4300 Millennium ACC Wood Burner Service And Maintenance Log Date of Service Performed By Description of Service...

Страница 12: ...verage under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whicheve...

Страница 13: ...ents not supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or...

Страница 14: ...Page 14 7037 141D October 12 2015 2100 4300 Millennium ACC Wood Burner Homeowner s Notes...

Страница 15: ...C Wood Burner Service Parts 21M ACC AU 21M ACC NZ Beginning Manufacturing Date July 2012 Ending Manufacturing Date Active R Part number list on following pages 2100 Millennium Wood Stove Advanced Comb...

Страница 16: ...4 1 2 x 1 1 4 Qty 9 Req 4 2 Brick 5 3 4 x 4 1 2 x 1 1 4 Qty 3 Req 4 3 Brick 8 x 4 1 2 x 1 1 4 Qty 2 Req 4 4 Brick see diagram Qty 1 Req 4 5 Brick see diagram Qty 1 Req Brick Uncut Pkg of 1 832 0550 Pk...

Страница 17: ...6 7 Air Control Rod Guide 7033 210 16 8 Timer Only Replacement Assembly SRV480 1940 Y 16 9 Timer Arm Assembly 7033 034 Y 16 10 Door Gasket Front Air Timer Door 7033 282 Y 17 1 Door Assembly Black SRV7...

Страница 18: ...provide model number and serial number All parts listed in this manual may be ordered from an authorized dealer Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Gasket Glass Tape 5 FT 832 0460...

Страница 19: ...19 2100 4300 Millennium ACC Wood Burner Service Parts R 43M ACC NZ Beginning Manufacturing Date July 2009 Ending Manufacturing Date Active Wood Stove Part number list on following page 43M ACC NZ 1 2...

Страница 20: ...9 1 2 832 3390 Y 7 Tube Support Rack 7033 148 8 Baf e Fiber Board 9 1 2 W x 15 3 4 H Qty 2 SRV7037 112 Y 9 Brick Retainer 7033 149 10 Tube Channel Assembly Manifold Tubes SRV7033 023 Y 11 Label Burn R...

Страница 21: ...T NUMBER 16 Brick Assembly Complete Set Pkg of 20 SRV7037 003 16 1 Brick 9 x 4 5 x 1 25 Qty 12 Reg 16 2 Brick 6 x 4 5 Qty 4 Reg 16 3 Brick 9 x 4 5 with angle Qty 1 Reg 16 4 Brick 9 x 3 with angle Qty...

Страница 22: ...Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 18 1 Door Assembly Black DR 31 43BK FH 18 2 Hinge Pins 1 2 Black 7000 606 2 18 3 Door Handle Assembly 832 0540 Cam Latch 430 1141 Key Cam Latch 4...

Страница 23: ...om your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 19 Baf e Protection Channel SRV7033 298 Component Pack Includes Spring Handles 1 1 2 Inch 2 1 4 Inch Trimount Plug...

Страница 24: ...r phone Notes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow th...

Отзывы: