02/23

7039-802G

F. Sleeping Room

G. California - Prop65

This product and the fuels used to operate this product (wood), and the 

products of combustion of such fuels, can expose you to chemicals 

including carbon black, which is known to the State of California to 

cause cancer, and carbon monoxide, which is known to the State of 

California to cause birth defects or other reproductive harm. For more 

information go to: WWW.P65Warnings.ca.gov

WARNING

When installed in a sleeping room it is recommended that 

a smoke and/or CO alarm be installed in the bedroom. The 

size of the room must be at least 50ft³ per 1,000 Btu/hr 

stove input, if the stove exceeds the room size, outside air 

must be installed.

NOTE:

 Hearth & Home Technologies, manufacturer 

of this appliance, reserves the right to alter 

its products, their specifications and/or price 

without notice.

E. Mobile Home Approved

•  This appliance is approved for mobile home 

installations when not installed in a sleeping room and 

when an outside combustion air inlet is provided.

• 

The structural integrity of the mobile home floor, ceiling, 

and walls must be maintained.

• 

The appliance must be properly grounded to the frame 

of the mobile home with #8 copper ground wire, and 

chimney must be listed to UL103 HT or a listed UL-

1777 full length six inch (152mm) diameter liner must 

be used.

• 

Outside Air Kit, part OAK-ACC must be installed in a 

mobile home installation.

Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage.

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

D. Glass Specifications

This appliance is equipped with 5mm ceramic glass. 

Replace glass only with 5mm ceramic glass. Please 

contact your dealer for replacement glass.

 

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be 

voided by, the following actions:

• 

Installation and use of any damaged appliance. 

• 

Modification of the appliance.

• 

Installation other than as instructed by Hearth & 

Home Technologies.

• 

Installation and/or use of any component part not 

approved by Hearth & Home Technologies.

• 

Operating appliance without fully assembling 

all components.

• 

Operating appliance without legs attached (if 

supplied with appliance).

• 

Do NOT Over fire

 - If appliance or chimney 

connector glows, you are over firing.

Any such action that may cause a fire hazard. 

Содержание 21M-ACC-C

Страница 1: ...MATIC COMBUSTION CONTROL ACC MODEL NUMBER 21M ACC C If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store o...

Страница 2: ...8 in USA Fuel loading door 5 3 4 in 2 1 4 in 29 5 8 in minimum 39 in minimum CANADA 203mm 8 in 203mm 8 in 203mm 8 in 457mm 18 in 1245mm 49 in minimum 1006mm 39 5 8 in minimum Made in U S A of US and...

Страница 3: ...7 B Appliance Emissions Certification 7 C BTU Efficiency Specifications 7 D Glass Specifications 8 E Mobile Home Approved 8 F Sleeping Room 8 G California Prop65 8 2 Operating Instructions A Over Fir...

Страница 4: ...on boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baffles 6 years 3 years X...

Страница 5: ...overed by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRANTY...

Страница 6: ...INDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The appliance...

Страница 7: ...r Output 44 400 Vent Size 6 inches Firebox Size 1 48 cubic feet Recommended Log Length 16 inches Fuel Seasoned Cord Wood 20 moisture Weighted average LHV Low Heating Value efficiency using Douglas Fir...

Страница 8: ...maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diam...

Страница 9: ...ver such as in a shed or covered with a tarp plastic tar paper sheets of scrap plywood etc as uncovered wood can absorb water from rain or snow delaying the seasoning process C Burning Process In rece...

Страница 10: ...n the stove top after start up you know the stove is hot enough and it may be time to adjust the air control if a sufficient ember bed has also been established Note that the stove will warm up much s...

Страница 11: ...Combustion Control system an over fire situation can occur and may result in a chimney fire Over firing will void the appliance warranty WARNING Injury Risk Gloves recommended CAUTION Figure 11 2 HIG...

Страница 12: ...are in the immediate area of the appliance Be sure the room is adequately ventilated and the flue unobstructed 5 Light the paper in the appliance NEVER light or rekindle fire with kerosene gasoline or...

Страница 13: ...turning the speed control clockwise to Low or counterclockwise to High 3 Snap Disc Location If you find the blower coming on and off at undesirable temperatures relocate the snap disc to another locat...

Страница 14: ...rnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should...

Страница 15: ...he speed is increased CONTACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer Table 15 1 Fire Risk DO NOT BURN GARBAGE OR FLAMM...

Страница 16: ...r 4 cords of wood The chimney and chimney cap must be inspected for soot and creosote every two months during the burn season or more frequency if chimney exceeds or is under 14 16 ft 4 3m 4 8m measur...

Страница 17: ...nnector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it should be removed t...

Страница 18: ...lass helping to keep smoke from adhering to its surface When operated at a low burn rate less air will be flowing over the glass and the smokey relatively cool condition of a low fire will cause the g...

Страница 19: ...with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket WARNING Fire Risk Firebox damage due to improper baffle placeme...

Страница 20: ...ge 13 of the Installation manual Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Wood Selection Storage on page 9 Bed of coals not e...

Страница 21: ...r will permanently stain glass on next firing Refer to maintenance instructions NOTE Replace with 5mm ceramic glass only Service Part SRV7000 013 1 Ensure that the fire is out and the appliance is coo...

Страница 22: ...SRV230 0470 1 Locate the snap disc bracket assembly at the bottom left rear corner of the appliance 2 A magnet holds the bracket to the appliance Pull the bracket down away from the appliance to expos...

Страница 23: ...eramic blanket 4 Re install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 23 3 and Figure 23 4 5 To re instal...

Страница 24: ...r to replace the tube channel assembly a clearance of 19 inches 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the...

Страница 25: ...25 02 23 7039 802G 6 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 26: ...26 02 23 7039 802G Date of Service Performed By Description of Service...

Страница 27: ...ervice Parts 21M ACC C Beginning Manufacturing Date Feb 2020 Ending Manufacturing Date Active R Part number list on following pages 2100 Millennium Wood Stove Advanced Combustion Control ACC 01 23 1 2...

Страница 28: ...832 0550 Pkg of 6 832 3040 4 2 Brick 5 3 4 x 4 1 2 x 1 1 4 Qty 3 Req SRV7128 039 4 3 Brick 8 x 4 1 2 x 1 1 4 Qty 2 Req SRV7128 022 4 4 Brick see diagram Qty 1 Req SRV7128 807 4 5 Brick see diagram Qt...

Страница 29: ...in H SRV7000 013 Y Gasket Glass Tape Field cut to Size 5 Ft Length 832 0460 Y 10 4 Frame Glass GL FRM 21M 10 5 Screw Flat Head Philips 8 32 x 1 2 Pkg of 12 220 0490 12 Y 11 Door Handle Assembly 832 05...

Страница 30: ...SRV7039 002 17 Tube Channel Top Access Cover SRV7039 114 Component Pack SRV7039 057 18 1 Burn Rate Control Assembly SRV7039 016 18 2 Spring Handle 1 4 Black SRV7000 614 Y 18 3 Timer Air Control Assem...

Страница 31: ...lower Control Box W Switch SRV7000 194 Y Blower Convection 812 4900 Y Component Pack 7033 051 Snap Disc Bracket Assembly SRV7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness Blower 703...

Страница 32: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...