background image

3

sulfate crystals. This allows your battery to accept more power than other 
chargers can provide. Our patented PULSE technology is NOT “Pulse 
Charging” which is commonly used in the market place today. It IS a total-
ly unique 1-2 punch provided by the independent application of our unique 
high frequency conditioning pulse on one circuit and proprietary charging 
algorithms on another. This helps ensure that your new batteries will stay 
in like-new condition while your older batteries often improve dramatically.  

2 4   V O L T   S Y S T E M   U S E

Many 24 volt battery systems are composed of two (2) 12V batteries. These 
two batteries are connected “in series.” These systems are often used with 
heavy-duty, industrial or alternate energy applications. The Xtreme Charge

®

 

X2 is a great solution for 24 volt systems because each battery is charged 
and maintained independently. The X2 will test, charge, pulse and maintain 
each battery for longer useful life and optimal performance. You may leave 
the batteries connected in series (24V) without concern that the charger 
will be damaged by 24 volts. The X2 will not be damaged by these 24 volt 
systems and the X2 will not damage batteries, no matter how long it stays 
connected. Connection to each battery is easy with heavy duty lugs or 
spring clips (two sets of each are included with the X2).

S P E C I F I C A T I O N S

Xtreme Charge

®

 X2 includes charger with 2 sets of fuse-protected quick-

disconnect battery clamps and lugs, Important Safety Instructions and 
Feature and Use Guide.

Charge Output Channels - 

2

Internal Power Supply - 

2 Fully Independent

Input Voltage - 

100 - 250 V AC

Maximum Charge Current - 

2.5A (5.0 Effective) per channel

Nominal Float Voltage - 

13.6V per channel

Maximum Bulk Charge Voltage - 

14.8V per channel

Pulse Frequency - 

40-50 kHz per channel

Functional Output Cable Length - 

8’ per channel

Agency Listing - 

CUL Approved

Housing - 

Weatherproof Rubberized base

Содержание XC-QL4-K2

Страница 1: ...on 1100 South Kimball Avenue Southlake TX 76092 9009 800 580 7554 ppc pulsetech net www pulsetech net What s Included QuadLink 4 Station Charger Multiplier XC QL4 2 2 Station Battery Maintenance Charger X2 1 Battery Tester XC 822 TEST 1 2 Battery Leads with Clips XC CLIPS 2 2 Battery Leads with Lugs XC LUGS 10 5 Battery Extension Lead XC EXT 5 8 25 Battery Extension Lead XC EXT 25 4 2 pin output c...

Страница 2: ... battery post 10 Plug battery charger into 110 220 VAC power source 11 Charge battery until it s fully charged This is shown by the green 100 LED illuminating 12 Connect your battery charger s 2 pin output connector to the 2 pin input connector of the QuadLink Fig 2 13 Connect the QuadLink 2 pin output connector to the 2 pin input connector of either the battery lead with lugs or battery lead with...

Страница 3: ...Model X2 12 Volt Charger FEATURE AND USE GUIDE By ...

Страница 4: ...t determines the battery is faulty and cannot be re charged A proprietary microprocessor controlled integrated charging process measures both voltage and current and applies only the amount of charge your battery is able to accept at any given time As the patented pulse technology is applied in combination with the saturation charge the bat tery s condition improves This proprietary process inhibi...

Страница 5: ...nput If it s connected to battery correctly red Test LED lights indicating unit is testing battery s condition FAULT CONDITIONS If red No Connection light illuminates charger is not connected to battery or inline fuse on positive battery lead needs to be replaced Should all the lights flash on and off and an audi ble warning buzzer be heard battery clamps are connected in reverse Refer to Safety I...

Страница 6: ...5 or 100 After battery is charged fully green 100 light illuminates and Charging light goes off This indi cates charger is providing float charge to battery It may now be placed into service or left on the Xtreme Charge indefinitely to maintain peak condi tion If battery has been pulsing and charging for 24 hours continuously without reaching 100 state of charge unit discontinues charging Red Bad ...

Страница 7: ...ned independently The X2 will test charge pulse and maintain each battery for longer useful life and optimal performance You may leave the batteries connected in series 24V without concern that the charger will be damaged by 24 volts The X2 will not be damaged by these 24 volt systems and the X2 will not damage batteries no matter how long it stays connected Connection to each battery is easy with...

Страница 8: ... and 2 the owner is not the original purchaser that purchased the product through an authorized PulseTech dealer or distributor This warranty is void if owner attempts to disassemble the unit or to modify the cable assemblies IN NO EVENT SHALL PULSETECH BE LIABLE FOR ANY DIRECT SPECIAL INDIRECT CONSEQUENTIAL INCIDENTAL PUNITIVE OR EXEMPLARY DAMAGES EXPENSES LOST SAVINGS OR LOST PROFITS OR ANY OTHE...

Страница 9: ...5 ...

Страница 10: ...g Part 100X827 Model XC CLIPS Leave On Battery Lead with Lugs Xtreme Charge 7 5 amp fuse protected cable comes with a quick disconnect termi nal Lead is 2 feet long Part 100X830 Model XC LUGS 12V Xtreme Charge w Pulse Maintenance Ideally suited for AGM and Maintenance Free batteries Increases the duty and life cycle of all 12V batteries up to five times longer Part 100X010 Model XC100 P 12V 2 Chan...

Страница 11: ...FEATURE AND USE GUIDE Model XC QL4 4 Channel 6 12V DC Charger Multiplier ...

Страница 12: ... has multiplied this useful application by 4 times turning any 6V or 12V DC battery charger using the stan dard 2 prong output connector into a 4 station maintenance charger There s no more need to spend time or to remember to switch back and forth between vehicles or batteries in storage Utilizing a simple plug and play system QuadLink automatically splits and distributes 10 minute charge segment...

Страница 13: ...f the QuadLink Note The charger must have the same industry standard 2 prong connector to mate properly with the QuadLink 3 Connect the extension leads that come with the QuadLink to either the standard attached battery eyelet connector on each vehicle battery and or to the charging clip set that comes with your charger Be sure to first connect the red battery clip to the positive battery terminal...

Страница 14: ...ls after a circuit verification test G If you replace or add a battery to an open channel again it is always best to unplug the QuadLink from the charger and the charger from the AC power source first Once you have connected the new battery to the circuit and plugged the units back in the QuadLink will reset and recognize the additional battery in the circuit and begin the process again Use Commen...

Страница 15: ...ing the provided eyelet lug connectors up to 4 to each of the 6V or 12V segments of the multiple battery configurations and in doing so allow the QuadLink to maintenance charge each of the 6V or 12V segments of the pack in 10 minute intervals This will ensure that the entire pack is maintained at the state of charge that they were left at when stored or left unused for an extended period Specifica...

Страница 16: ...e and AGM battery with a charger that requires the use of a battery selection dial for charging different battery types what happens We suggest that you do not use the QuadLink with this type of charger Consider buying an Xtreme Charge to properly charge all these types on the QuadLink au tomatically 8 If there is no battery connected is power flowing to the battery clips or eyelet connector The a...

Страница 17: ...control of PulseTech or B damaged in transit to PulseTech or 2 the owner is not the original purchaser that purchased the product from PulseTech directly or through an authorized PulseTech dealer or distributor IN NO EVENT SHALL PULSETECH BE LIABLE FOR ANY DIRECT SPECIAL INDIRECT CONSEQUENTIAL INCIDENTAL PUNI TIVE OR EXEMPLARY DAMAGES EXPENSES LOST SAVINGS OR LOST PROFITS OR ANY OTHER DAMAGES OF A...

Страница 18: ...tion maintenance charger Part 100X004 Model XC QL4 Battery Lead with Clips This 7 5 amp fuse protected cable is supplied with a quick disconnect terminal Lead is 2 feet long Part 100X827 Model XC CLIPS Leave On Battery Lead with Lugs Xtreme Charge 7 5 amp fuse protected cable comes with a quick disconnect terminal Lead is 2 feet long Part 100X830 Model XC LUGS 5 and 25 Extension Lead Extend a stan...

Отзывы: