Qtx UMBRA-1200 Скачать руководство пользователя страница 5

 

160.480UK User Manual

 

Operation 
 

Before mist can be produced, the UMBRA-1200 needs to heat up, for 3 to 5 minutes. 
If the display shows 

Warming

, the heater is pre-heating. 

 
If the display shows 

Ready to Fog

, it is at the required temperature for operation. 

Settings and standalone operation are entered on the control panel as follows.

 

 

Display (FUNC) 

Setting (UP/DOWN) 

Description 

Man Vol

 

1% - 100% (percent)

 

Mist Volume in Manual operation 

Interval Set

 

1s - 900s (seconds)

 

Interval between output on timer 

Duration Set

 

1s - 200s (seconds)

 

Duration of output on Timer 

Volume OUT

 

1% - 100% (percent)

 

Mist Volume in Timer operation 

Wind Set

 

1% - 100% (percent)

 

Mist blowing fan speed 

DMX512 Add

 

001-512

 

Set the DMX start address 

 

To produce mist on demand, press MANUAL and the START/STOP button for continuous mist 

output and press again to stop. The internal Manual and Wind Set settings will affect the 
amount and rate of output. 

 
To initiate a timed output, using FUNCTION and UP/DOWN buttons, set the required 

Duration (mist output) and Interval (no mist output) times and then press TIMER to 
initiate the timer (time countdown will show in the display) 
Press TIMER again to stop the timer operation. 

 
The Volume OUT and Wind Set settings will affect the amount and rate of output. 

To operate remotely via DMX, use FUNCTION and UP/DOWN buttons to set the DMX 
start address and then operate across 3 DMX channels as described below 

(Note: If a DMX signal is being received, this will override Manual or Timer modes) 
 

 
After use, switch off the mist output and wait until no more mist is produced. 

Unplug from the mains supply and allow the unit to cool down. 
Remove and empty the fog fluid tank and empty the water reservoir via a tap near the 

bottom. 
 

Stow away or replace the control panel if removed from the housing. 
Replace the funnel and flexible duct before fitting the lids and moving the UMBRA-1200

 

 

 
 
 

DMX Channel 

Value 

Function 

Channel 1 (start address) 

0-255 

Mist output volume 0%-100% 

Channel 2 (start a 1) 

0-255 

Fan speed 0%-100% 

Отзывы: