160.478UK User Manual
CH6
0-5
No LED effect
6-127
LED color changing mode
128-255
LED gradual change mode
CH7
0-255
LED effect speed slow to fast
Specifications:
Power supply
230Vac, 50Hz (IEC)
Fuse
F10A
Heating element
2000W
Reheat time
5 to 6 mins (approx.)
Fog output (approx.)
72,000 Cu Ft (1133m³)/ min
Tank capacity
5.5 litres
LED power
3W x 6pcs
RF Remote frequency
433MHz
DMX connection
XLR (3-pin/5pin) in/out (6-channel)
Dimensions
550 x 280 x 280mm
Weight
10kg
Troubleshooting
Warning: Hot components! ... Switch off and allow to cool before touching the unit.
No light on mains
switch
Check mains voltage is correct and socket is switched on
Check IEC lead is OK and connected properly
Check mains fuse in IEC connector and fuse in plug top
If fuse blowing repeatedly, refer to qualified service personnel
Ready message is
on but no fog
output
Check fog fluid level
If fluid is OK and pump working, the lines may be blocked
Check that nozzle is not blocked or obstructed
If blocked, clean with fog machine cleaner & distilled water
No response to
DMX
Check that XLR leads are connected properly
Check that DMX signal is OK by testing on other equipment
Check the DMX settings are set to the correct address
Ensure that the other remote control is not overriding DMX
No LED output
Check LED settings on rear control panel
Check LED is not switched off on RF remote
This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its
useful life. The goods must be disposed of according to your local council guidelines.
Errors and omissions excepted.
Copyright© 2022 AVSL Group Ltd, Unit 2 Bridgewater Park, AVSL (Europe) Ltd, Unit 3D North Point House,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
North Point Bus. Park, New Mallow Road, Cork, Ireland.