QTX Light PAR64 Скачать руководство пользователя страница 3

User Manual 

 

 

 

153.772 / 153.775

 

 

 

Do not use solvents or aggressive detergent to clean the device. Use a soft and clean cloth. 

 

Do not modification the device or the connected power cord without authorized. 

 

Use appropriate safety-rope for safety. 

 

Do not stare to the light 

 

The symbol 

determines the minimum distance from lighted objects. The minimum 

distance between light-output and the illuminated surface must be more than 0.1m. 

 

6

 

Connect with power supply - The ground wire must be connected : 

Use the plug to connect to the main power supply as following.   

 

Line

 

Connection

 

International signal

 

Brown

 

Live

 

L

 

Blue

 

Neutral

 

N

 

Yellow /Cyan

 

Earth

 

 

 

7

 

Quick Trouble Shooting : 

7.1 if the unit is not functioning – Check if main power is on and fuse. 

7.2 if the unit is not reacting to music – check the sensitivities switch at rear of the device. 

 

8. Replacing Fuse :     

Disconnect from the main power supply first, then unscrew the fuse holder cover to reveal the fuse. 

Replace the correct fuse rating as stated on lighting or user guide. Then, screw on fuse holder cover. 

 

9. General Maintenance : 

To maintain optimum performance and minimize wear fixtures should be cleaned frequenctly. Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should be 

cleaned  at  least  twice  a  month.  Dust  build  up  reduces  light  output  performance  and  can  cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance.   

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected 

on external vents and internal components. Clean all glass when fixture is cold with a mild solution and 

a cloth or tissue, and drag dirt and grime to the outside of the lens. Gently polish optical surface until 

they free of haze and lint. 

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 

damp, smoky or particularly dirty surroundings can require cleaning fluid. Always dry the parts carefully. 

Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.   

 

 

 

 

 

Отзывы: