Пользовательский мануал для QTS AN-X4-ABRIO-HMI доступен для бесплатного скачивания на нашем сайте. Научитесь использовать это устройство с нашим подробным руководством. Посетите manualshive.com для загрузки.
UPDATING THE FIRMWARE
45
SPECIFICATIONS
46
SUPPORT
47
WARRANTY
48
Страница 1: ...AN X4 ABRIO HMI User Manual...
Страница 2: ...ts associated with any particular installation Quest Technical Solutions does not assume responsibility or liability to include intellectual property liability for actual use based upon the examples s...
Страница 3: ...nation 10 Ethernet Cabling 11 Hazardous Location Considerations 11 CONFIGURATION 12 Initial Ethernet Configuration 12 DHCP 13 Static IP Address 13 Factory Default Setting 13 Hostname 13 Submitting the...
Страница 4: ...omation Network 27 Remote I O HMI Configuration 27 Configuration View 28 RIO Discrete Data 30 RIO Block Transfers 32 RIO Diagnostics 34 Log Files 38 RIO HMI Log 38 System Info Log 38 View All Logs 38...
Страница 5: ...UPDATING THE FIRMWARE 45 SPECIFICATIONS 46 SUPPORT 47 WARRANTY 48...
Страница 6: ...I O baud rates supports block transfer reads and writes at all possible locations on these racks Ethernet IP devices access data on the AN X as PLC 5 input I output O status S integer N binary B and f...
Страница 7: ...remote I O network NS an Ethernet connector a 3 pin Phoenix connector to connect to the remote I O network a 3 pin Phoenix power connector a microSD card for storage of configuration data and firmware...
Страница 8: ...g txt Remote I O Configuration RioHmi AnxAbRioHmiCfg txt Firmware to run Firmware FirmwareCfg txt All files should be created and edited with a plain text editor such as Windows Notepad If the AN X4 i...
Страница 9: ...There can now be up to 64 possible block transfer read lengths and 64 possible block transfer write lengths AN X4 allows you to specify all other block transfer locations as well as the block transfer...
Страница 10: ...osest to the Ethernet connector Power consumption is 240 mA 12VDC or 120 mA 24VDC The part number for the power connector is Phoenix MSTB 2 5 3 ST 5 08 1757022 The power connector is the same as the A...
Страница 11: ...O connection errors are wiring reversed lines 1 and 2 incorrect baud rate other cabling and termination problems terminating resistors shorted to shield wires duplicate racks Usually but not always th...
Страница 12: ...s Otherwise the DHCP server may assign a different IP address each time AN X powers up and any software that accesses the AN X module would have to be reconfigured If you are using multiple AN X modul...
Страница 13: ...y a pause The NS LED will be solid red Static IP Address If you select static IP address enter the IP address for the AN X the netmask for the AN X the default gateway for your network You must enter...
Страница 14: ...known State It sometimes happens that an AN X has been previously configured with an IP address that causes it to be inaccessible on the current Ethernet network or that the IP address is unknown Remo...
Страница 15: ...an error code on the MS LED see page 43 Example IPCfg IPConfig txt files Example Factory default IP Factory Hostname ANX4 Example DHCP IP DHCP Hostname ANX4 Example Static IP address IP 192 168 1 14...
Страница 16: ...at the end of a line or on a separate line The file can also contain blank lines You transfer the configuration to the AN X using the web interface see page 27 Baud Rate The baud rate is defined by a...
Страница 17: ...up slot PLC 5 file and offset length The rack number is in the form 0onn where nn is the rack number from 0 to 76 octal By default rack numbers are octal You can override with 0d for decimal or 0x for...
Страница 18: ...e I O location rack I O group and slot When the remote I O scanner requests a block transfer at that location the AN X uses the requested length to select which data to access Block transfers by lengt...
Страница 19: ...and RunSts bits S2 16 S2 63 The default is 250 ms the allowed range is 10 44000 ms It may take 2 poll periods to clear the status bits since the polling and the I O scan are asynchronous If the AN X...
Страница 20: ...k 0o00 4 4 Rack 0o01 1 4 racks 1 2 and 3 are full racks Rack 0o02 1 4 Rack 0o03 1 4 btr 0o02 0 0 N7 0 12 block transfer read mapped to integer file btw 0o02 0 0 N7 20 10 block transfer write mapped to...
Страница 21: ...Do not use ProSoft ANX connected device Other HMIs Access data on the AN X as you would any other PLC 5 I O Data Discrete I O Data Discrete data is mapped to PLC 5 I input and O output files based on...
Страница 22: ...se of protocol error UpdCur S2 8 Update time for the last scan in ms UpdAvg S2 9 Average time of the last 32 scans in ms UpdMin S2 10 Minimum scan time in ms since the last reset UpdMax S2 11 Maximum...
Страница 23: ...t Status racks 44 47 S2 42 Input Status racks 50 53 S2 43 Input Status racks 54 57 S2 44 Input Status racks 60 63 S2 45 Input Status racks 64 67 S2 46 Input Status racks 70 73 S2 47 Input Status racks...
Страница 24: ...size mismatch the InpSts bit will be set because we are getting or sending valid input packets If the scanner continues to send RST packets because it s not happy the OutSts bit for the rack will not...
Страница 25: ...ULL RACK For a full rack bit 0 is set if the rack is being scanned and Is 0 otherwise 4321 0001 I O groups 6 7 Quarter 4 I O groups 4 5 Quarter 3 I O groups 2 3 Quarter 2 I O groups 0 1 Quarter 1 HALF...
Страница 26: ...he corresponding bit is set Word 0 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 I O group 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 Slot 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 R W R W R W R W R W R W R W R W R W Word 1 B...
Страница 27: ...ove firmware files on the AN X reboot the AN X It also contains contact information for support To access the web interface start your web browser and type the AN X IP address where you normally enter...
Страница 28: ...h shows the result to the last download Upload and store the configuration on the AN X Upload and store the sample configuration stored on the AN X as a starting point for creating a configuration fil...
Страница 29: ...s the occupied quarter racks for t each rack definition For example a quarter rack might be shown as ___ or _ __ or __ _ or ___ depending on the starting I O group Similarly a full rack would be shown...
Страница 30: ...na to write RIO I O data directly WARNING WrtEna is meant to be used for commisioning and testing by qualified personnel only Note I O data entered here may be overwritten by RIO Outputs RIO Inputs ma...
Страница 31: ...the next editable space At the start the display is based on configured racks If the AN X hears other racks for example higher numbered racks it resizes the display to show those racks as well If you...
Страница 32: ...ed The counters wrap around to 0 after they reach 63 If Auto Refresh is on the display refreshes once a second You can refresh the screen at any time by clicking Refresh At the start the display is ba...
Страница 33: ...hen WrtEna is on select a location to edit data and an edit box opens at the top of the screen Type the new value in the edit box and press enter to accept the value clear the edit window and remain a...
Страница 34: ...e block transfer is a block transfer read or write by length there will be an additional control that lets you select a specific length to see the data for that length Use the up and down arrows to se...
Страница 35: ...the display refreshes once a second You can refresh the screen at any time by clicking Refresh Click on any rack or partial rack to select it in the diagnostic counters table If Auto Refresh is on you...
Страница 36: ...d rack Rack Upd Min Minimum update time in ms observed for the selected rack Rack Upd Max Maximum update time in ms observed for the selected rack If Auto Refresh is on the display refreshes once a se...
Страница 37: ...ors Noise Errors Count of frames with noise errors Timeouts Count of timeouts Net Upd Cur Update time for the last scan in ms Net Upd Avg Average scan time of the last 32 scans in ms Net Upd Min Minim...
Страница 38: ...record diagnostic and error messages Use the Log Files menu in the web interface to view these logs When the current log file becomes full AN X renames it so you can access it as the previous log file...
Страница 39: ...nds a DHCP server on the network it obtains an IP address and other network parameters netmask and default gateway from the DHCP server To find the address assigned look at the DHCP server or use a ne...
Страница 40: ...umber of the AN X module AN X Firmware Select Use Administration AN X Firmware Select to select a firmware qtf file the AN X is to run from the list AN X builds the list from the firmware files on the...
Страница 41: ...second web page Click the Download Capture File button to save the file to your computer AN X Kernel Page Use Administration AN X Kernel Page to display the version of the Linux kernel on the AN X Thi...
Страница 42: ...the transfer is complete the AN X still has to copy the kernel file to the microSD card When the file copy is complete the AN X displays a message to indicate that the file was copied successfully Sta...
Страница 43: ...et both LEDs are off MS and NS LEDs The MS LED is used by the AN X operating system and software to indicate the state of operations and errors It should be used in conjunction with the logs to locate...
Страница 44: ...nfiguration file Red Pulse 250 ms Ethernet IP Error see RIO MHI Log RED 5 Ethernet IP server shutdown NS LED Meaning GREEN All Active racks are being scanned YELLOW Receiving good packets but not all...
Страница 45: ...hange the firmware the AN X is running run the command Administration Select AN X Firmware to select the file you wish to run You must restart the AN X4 to run the firmware that you selected or transf...
Страница 46: ...network Maximum Power Consumption 240 mA at 12 VDC 120 mA at 24 VDC Maximum Power dissipation 2 9W Environmental Conditions Temperature code T6 Operational Temperature 0 50 C 32 122 F Storage Tempera...
Страница 47: ...East Africa Languages Spoken French English 33 5 34 36 87 20 support EMEA prosoft technology com North America Languages Spoken English Spanish 1 661 716 5100 support prosoft technology com Latin Amer...
Страница 48: ...ch original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables nor to any damage resulting from battery leakage...