Installation Instructions
2
QTM-DC+CAP Field Wiring Made Simple
© Copyright Q-Tran, Inc. 2013
Q-Tran 155 Hill Street Milford, CT 06460 www.Q-Tran.com
RED = Positive
YELLOW = Negative
NOTE:
Primary Input - connect the 120V hot into block labeled Hot. Connect the neutral wire into Tap 1 - Tap 5 depending on desired output Voltage.(Not to exceed 12V or 24V)
Low Voltage
Line Voltage
+ 1 - + 2 -
+ 3 -
Must test all voltage readings with a True RMS Voltage Meter.
Land
Hot
Land
Ground
Land Neutral
on one tap.
Chose either tap
1,2,3,4 or 5
PRIMARY
SECONDARY
TAP2
TAP1
HOT
GND
Primary Input Load
TAP4
TAP5
TAP3
368.3mm
Rectifier
Class I
Wiring
LV
compartment
Class II wiring
Secondary
Breakers
14.5"
"
0
.
8
m
m
2
.
3
0
2
Cap
QTM60
QTM100
QTM120
QTM150
QTM180
QTM200
DC
DC
DC
DC
DC
DC
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
50/60
50/60
50/60
50/60
50/60
50/60
12/24
12/24
12/24
12/24
12/24
12/24
60
100
120
150
180
200
0.67 / 0.29
1.1 / 0.49
1.3 / 0.58
1.7 / 0.7
2.0 / 0.87
2.3 / 0.98
Model
Input Voltage
(V)
Frequency
Nominal Output
Voltage (VDC)
Nominal Output
Wattage (W)
Input Current
(A)
QTM240
QTM300
QTM360
QTM400
QTM500
QTM600
DC
DC
DC
DC
DC
DC
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
120 / 277
50/60
50/60
50/60
50/60
50/60
50/60
12/24
12/24
12/24
12/24
24
24
240
300
360
400
500
600
2.7 / 1.2
3.4 / 1.5
4.1 / 1.8
4.5 / 2.0
5.6 / 2.4
6.7 / 2.9
QTM60
QTM100
QTM120
QTM200
DC+CAP
DC+CAP
DC+CAP
DC+CAP
120 / 277
120 / 277
120 / 277
120 / 277
50/60
50/60
50/60
50/60
12/24
12/24
12/24
24
60
100
120
200
0.9 / 0.4
1.3 / 0.5
1.4 / 0.6
2.4 / 1.0
QTM-DC/DC+CAP
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
LOW VOLTAGE
LUMINAIRE POWER
SUPPLY CENTER
WALL MOUNT ONLY
FOR SUPPLY CONNECTIONS USE
WIRE RATED FOR AT LEAST 75 C.
SUITABLE FOR DAMP LOCATIONS
ISOLATION TOROIDAL TRANSFORMER
50/60 CYCLE A.C. ONLY
MADE IN THE U.S.A.
This product must be installed in accordance with the applicable installation code by a person familiar with the
construction and operation of the product and the hazards involved.
USE DIMMERS RATED FOR MAGNETIC
LOW VOLTAGE LOAD
Q-Tran, Inc.
239924
CLASS:
3425 - 15
3425 - 95
Yellow
Red
+
-
WIRE CONNECTION