background image

PREVENT STATIC SPARKING 

 

FIRE/EXPLOSIONS

 

Vapors created when spraying can be ignited by sparks.

 

To reduce the risk of fire, always locate the sprayer at least 20 feet (6 m.) away 

from spray area. Do not plug in or unplug any electrical cords in the spray area. 

Doing so can cause sparks which can ignite any vapors still in the air. Follow the 

coating & solvent manufacturers safety warnings and precautions.

 

 

MEDICAL ALERT INJECTION INJURIES

 

If any fluid appears to penetrate your skin, 

GET EMERGENCY MEDICAL CARE 

 

AT ONCE.  DO NOT TREAT AS AN ORDINARY CUT. 

High pressure fluids from 

spray or leaks are powerful enough to easily penetrate the skin and cause 

 

extremely serious injection injury, leading to the possible need for amputation.

 

+  

 

NEVER 

point the spray gun at anyone or any part of the body.

 

+  

 

NEVER 

put your hand or fingers over the spray tip. Do not use a rag or 

 

 

any other materials over your fingers. Paint will penetrate through these 

 

 

materials and into the hand.

 

+  

 

NEVER 

try to stop or deflect leaks with your hand or body.

 

+  

 

ALWAYS 

have the tip guard in place when spraying.

 

+  

 

ALWAYS 

lock the gun trigger when you stop spraying.

 

+  

 

ALWAYS 

remove tip from the gun to clean it.

 

+  

 

NEVER 

try to "blow back" paint, this is not an air powered sprayer.

 

+  

 

ALWAYS 

follow the 

PRESSURE RELIEF PROCEDURE 

before cleaning or 

 

 

removing the spray tip or servicing any system equipment.

 

+  

 

Be sure the equipment safety devices are operating properly before each use.

 

+  

 

Tighten all of the fluid connections before each use.

 

+  

 

NEVER 

alter equipment in any manner.

 

+  

 

NEVER 

smoke while in spraying area.

 

+  

 

NEVER 

spray highly flammable materials.

 

+  

 

NEVER 

use around children.

 

+  

 

NEVER 

allow another person to use sprayer unless he is thoroughly 

 

 

instructed on its safe use and given this operator

s manual to read.

 

+  

 

ALWAYS 

wear a spray mask, gloves and protective eye wear while spraying.

 

+  

 

ALWAYS 

ensure fire extinguishing equipment is readily available and 

 

 

properly maintained.

 

10

 

QTech

Spray.com

 

NEVER LEAVE SPRAYER UNATTENDED WITH PRESSURE IN THE SYSTEM.

 

FOLLOW PRESSURE RELIEF PROCEDURES AT ALL TIMES.

 

 

ALWAYS INSPECT SPRAYING AREA

 

+  

 

Keep the spraying area free from obstructions.

 

+  

 

Make sure the spraying area has good ventilation to safely remove 

 

 

vapors and mists.

 

+  

 

NEVER 

keep flammable material in spraying area.

 

+  

 

NEVER 

spray in vicinity of open flame or other sources of ignition.

 

+  

 

The spraying area must be at least 6 metres away from spray unit.

 

 

SPRAY GUN SAFETY

 

+  

 

ALWAYS 

set gun safety lock in the "LOCKED" position when not in use 

 

 

and before servicing or cleaning.

 

+  

 

NEVER 

remove or modify any part of the gun.

 

+  

 

ALWAYS REMOVE THE SPRAY TIP 

when cleaning. 

 

 

Flush unit at the 

LOWEST POSSIBLE PRESSURE

.

 

+  

 

ALWAYS 

check operation of all gun safety devices before each use.

 

+  

 

Be very careful when removing the spray tip or hose from the gun. 

 

 

A plugged line will contain fluid under pressure. If the tip or line is plugged, 

 

follow the 

PRESSURE RELIEF PROCEDURE

.

 

 

TIP GUARD

 

+  

 

ALWAYS 

have the tip guard in place on the spray gun while spraying. The 

 

 

tip guard alerts you to the injection hazard and helps prevent accidentally 

 

placing your fingers or any part of your body close to the spray tip.

 

 

SPRAY TIP SAFETY

 

+  

 

Use extreme caution when cleaning or changing spray tips. If the spray tip 

 

clogs while spraying, engage the gun safety latch immediately. ALWAYS 

 

 

follow the 

PRESSURE RELIEF PROCEDURE 

and then remove the spray 

 

 

tip to clean it.

 

+  

 

NEVER 

wipe off build up around the spray tip.

 

11

 

QTech 

QT290C Carry Airless Sprayer

 

Содержание QT290C Carry

Страница 1: ...ustrial Park Balbriggan County Dublin Ireland K32 KV26 Email sales aristospray com www QTechSpray com Phone UK 01895 276751 ROI 0 1690 3162 International 353 1690 3162 QTechSpray www QTechSpray com USER MANUAL QT290CCarry Airless Sprayer ...

Страница 2: ...scrap and pull trigger to clear Check tip for wear replace where necessary Check all filters are clear of debris clean or replace Ensure OK for coating tip combination change if necessary Check OK for spray thin where appropriate Check length diameter compatible with pump coating Check not obstructed with debris contact a QTech dealer or technician for advice Increase pressure If clogged reverse t...

Страница 3: ... spray gun TriTech Contractor 517 airless tip guard 1 4 x 15m textile braided hose assembly PRODUCT CODES 110 volt QT290C 110 240 volt QT290C 220 QTech QT290C Carry Quick change manifold filter Quick release wet end QTechSpray com 5 Filter cap Manifold filter Packing nut Suction tube Drain tube Suction filter Pressure control knob On off switch Prime valve QTech QT290C Carry Airless Sprayer For so...

Страница 4: ...ed sprayers must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use any adaptor plugs Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded If the sprayer should electrically malfunction or break down grounding provides a low re...

Страница 5: ...id pressure Hold metal part of the gun in contact with grounded metal pail 4 Turn the Priming Valve to the open priming position to relieve residual fluid pressure 5 Re engage gun safety latch and close Priming Valve If the SPRAY TIP OR HOSE IS CLOGGED follow Step 1 through 5 above Expect paint splashing into the bucket while relieving pressure during Step 4 QTechSpray com SPECIFIC SAFETY RULES HA...

Страница 6: ...ldren NEVER allow another person to use sprayer unless he is thoroughly instructed on its safe use and given this operator s manual to read ALWAYS wear a spray mask gloves and protective eye wear while spraying ALWAYS ensure fire extinguishing equipment is readily available and properly maintained 10 QTechSpray com NEVER LEAVE SPRAYER UNATTENDED WITH PRESSURE IN THE SYSTEM FOLLOW PRESSURE RELIEF P...

Страница 7: ... in serious bodily injury and property damage For detailed instructions on how to ground check your local electrical code ALWAYS ensure switch is in OFF position before plugging unit in Always ground all of these components 1 Sprayer plug the power supply cord or extension cord each equipped with an undamaged three prong plug into a properly grounded outlet DO NOT USE AN ADAPTER Use only a 3 wire ...

Страница 8: ... there is no pressure in the unit and close the prime pressure relief valve for storage 4 Start up after storage Before using water base paint flush with soapy water and then with clean water When using oil base paint flush out the pump conditioner with the material to be sprayed HOW TO FLUSH 1 Be sure the gun safety latch is engaged and there is no spray tip in the gun 2 Pour enough clean compati...

Страница 9: ... pressure d Check the spray pattern The tip size and angle determines the pattern width and flow rate Spray a test pattern and then adjust the pressure to eliminate heavy edges Use a smaller tip size if the pressure adjustment cannot eliminate heavy edges e While spraying hold the gun perpendicular about 25 30cm 10 12 inches away from the surface Spray back and forth Trigger the gun before moving ...

Страница 10: ...ate solvent Change or clean filters at least once a day Some types of latex may require a filter change after about four hours of operation SPRAY TIP SELECTION Spray tip selection is based on paint viscosity paint type and job needs Generally use a smaller tip for light viscosities thin paints and use a larger tip for heavier viscosities thicker paints Spray tip size is based on how many litres of...

Страница 11: ... no longer maintain pressure has difficulty priming and paint seeps into the throat of the pump and tightening the packing nut no longer helps then the packings will require replacement This is best entrusted to a qualified repair technician To remove the pump and replace the packings follow the instructions below PUMP REMOVAL 1 Remove the high pressure hose 62 from the back of the pump housing us...

Страница 12: ...NG SPACER 1 13 12 015 BALL SEAT FASTENER 1 14 12 011 O RING Ø9 x Ø13 x 2 1 15 12 010 BALL SEAT Ø4xØ13 8x4 1 16 12 012 UPPER CHECK BALL Ø6 35 1 17 12 290 022 COMPLETE DISPLACEMENT PISTON see below 1 18 12 009 DISC SPRING Ø18xØ34 7x1 3 19 12 014 O RING VITON 1 20 12 013 O RING TEFLON 1 21 12 019 SEAL SEAT Ø27xØ35 1 22 12 018 PACKING NUT M38xP1 5 1 23 12 290 032 RETAINING RING Ø1 2xØ24 8 1 24 12 290 ...

Страница 13: ...6 PANHEAD MACHINE SCREW M4 x 10 1 70 12 290 097 EARTHING MARKING 1 71 12 017 PANHEAD TAPPING SCREW M4x12 4 72 1 12 290 091 1 ELECTRONICS UNIT 110V 1 72 2 12 290 091 2 ELECTRONICS UNIT 220V 1 73 12 290 100 CURRENT PROTECTOR 1 74 12 290 120 SPEED CONTROL 110V 220V 1 75 12 135 SOCKET SET SCREW M4 x 8 1 76 12 064 SUCTION POWER CONTROL DIAL 1 77 12 290 108 HEX NUT M3 4 78 12 290C 091 LCD DISPLAY 110V 2...

Страница 14: ... table MANIFOLD FILTER 1 61 12 290C 070 FILTER CAP ALU 1 62 12 290 085 HIGH PRESSURE HOSE 1 4 18UNF 1 63 12 003 OUTPUT NIPPLE 2 64 12 290 075 PRIMING VALVE 1 QTechSpray com 27 Frame ITEM PRODUCT CODE DESCRIPTION QTY 100 12 290C 021 FRAME 1 101 12 290C 022 END CAP INNER 4 102 12 290C 023 END CAP OUTER 4 103 12 001 PACKING NUT TOMMY BAR 1 104 Q400 005 Q LUBE PISTON LUBRICANT 1 105 12 290 300 PUMP BO...

Страница 15: ...28 Wiring Diagram QTechSpray com 29 QTech QT290C Carry Airless Sprayer ...

Страница 16: ...30 QTechSpray com 31 QTech QT290C Carry Airless Sprayer ...