Step 2: Insert the QSW-2GB module to the guide rail inside the 10Gb module slot.  

Step 3: Push the QSW-2GB module along the guide rail gently until it comes into contact with 
the machine panel. 

Step  4:  Insert  the  SFP  transceiver  to  the  guide  rail  inside  the  QSW-2GB.  Do  not  put  the  SFP 
transceiver up-side-down. 

Step 5: Push the SFP transceiver along the guide rail gently until it comes into contact with the 
QSW-2GB. 

Note: the 2GB extended module does not support hot swappable. 

 

Caution! 

Do  not  stare  directly  at  the  2  fiber  bores  in  the  fiber  transceiver  when  the  switch  is  in 
operation, otherwise the laser may hurt your eyes. 

2.3.6 

Copper Cable/Fiber Cable Connection 

Copper cables should be connected as below:  

Step  1:  Insert  one  end  of  the  Ethernet cable  to  the  RJ-45 Ethernet port  in  the  switch  copper 
cable line card; 

Step 2: Insert the other end of the Ethernet cable to the RJ-45 Ethernet port of other device; 

Step 3: Check all status indicators for the corresponding ports; a lighted LED indicates that the 
link has been established, otherwise the link is not ready and the cable should be examined. 

 

Caution! 

Please verify the sign above the port to ensure using the right port. Connecting to wrong ports 
might damage the switch.  

 

Fiber cables should be connected as below:  

Step  1:  Remove  the  protective  plug  from  the  SFP/SFP+  fiber  transceiver  bore;  Remove  the 
protective cap from one end of the fiber cable. Keep the fiber end clean and neat. 

Step 2: Attach one end of the fiber cable to the SFP/SFP+ transceiver, and attach the other end 
to  the  transceiver  of  the  corresponding  devices.  Note:  The  SFP/SFP+  transceiver’s  TX  port 
should be connected to the RX port of the corresponding device, and vice versa. 

Step  3:  Check  the  fiber  port  status  indicator,  a  lighted  LED  indicates  that  the  link  has  been 
established; otherwise the link is not ready and should be examined. 

 

Caution! 

Содержание QSW-8200 series

Страница 1: ...USER MANUAL www qtech ru...

Страница 2: ...1 1 Environmental Requirements 19 2 1 1 1 Dust and Particles 19 2 1 1 2 Temperature and Humidity 20 2 1 1 3 Power Supply 21 2 1 1 4 Preventing Electrostatic Discharge Damage 21 2 1 1 5 Anti interfere...

Страница 3: ...www qtech ru 2 3 7 AC Power Supply Connection 28 2 3 8 DC Power Supply Connection 28 2 3 9 PoE Power Supply Connection 29...

Страница 4: ...ports 4 Combo ports 2 10Gb extended ports QSW 8200 52T AC DC 44 copper ports 4 Combo ports 2 10Gb extended cards DC power QSW 8200 52T POE AC DC 44 copper ports 4 Combo ports 2 10Gb extended cards PoE...

Страница 5: ...QSW 8200 52F AC DC can input 48V DC power QSW 8200 28F AC does not have the DC input interface 1 2 2 Features and Benefits Various Interfaces QSW 8200 52T AC QSW 8200 52T AC DC and QSW 8200 52T POE AC...

Страница 6: ...ch also support IEEE802 1x port based access authentication which can be deployed with RADIUS to ensure the port level security and block illegal users QoS QSW 8200 series switches fully support DiffS...

Страница 7: ...Mb Combo ports 2 interfaces with extended card 44 100 1000Base TX auto negotiation ethernet ports 4 1000Mb Combo ports 2 interfaces with extended card Managemen t ports 1 Console port System power QSW...

Страница 8: ...es Ethernet switches provide 20 100 1000Base TX auto negotiation ehternet ports 4 1000Mb Combo ports 6 function indicators and 1 Console port Fig 1 1 Front Panel of QSW 8200 28T AC Fig 1 2 Front Panel...

Страница 9: ...AC DC QSW 8200 28F AC Ethernet switch provides 12 1000Mb fiber ports 12 1000Mb Combo ports 8 function LEDs and 1 Console port Fig 1 7 Front Panel of QSW 8200 28F AC DC Fig 1 8 Front Panel of QSW 8200...

Страница 10: ...8T POE AC DC Back Panel of QSW 8200 52T AC is same with QSW 8200 28T AC it supplies 2 plug in interfaces 1 48V input power interface 1 input power interface of PoE and 1 220V input power interface Fig...

Страница 11: ...r input and 1 interface with 220V AC power input Fig 1 18 Back Panel of QSW 8200 52F AC DC 1 4 3 DC Power PoE Power Input QSW 8200 supports AC DC input power backup and PoE output power pin outs signa...

Страница 12: ...SW 8200 52T AC DC QSW 8200 52T AC DC QSW 8200 52T POE AC DC the LEDs include two parts one is 24 48 1000M interface LEDs they show each port state at RJ45 plug in each port corresponds a LED with doub...

Страница 13: ...lace Off M1 is not in place M2 On Green M2 is in place Off M2 is not in place LEDs of QSW 8200 28F AC DC QSW 8200 28F AC QSW 8200 52F AC DC show the corresponding state There are two kinds of LEDs on...

Страница 14: ...ker respectively The other of its kind is system LEDs system LEDs of QSW 8200 28F AC DC QSW 8200 28F AC and QSW 8200 52F AC DC are at the right of the front panel They are corresponding name for syste...

Страница 15: ...t1 of M2 is at link state On Green Blink Port1 of M2 is receiving or sending the data Off Port1 of M2 is not at link state M2 2 On Green Port2 of M2 is at link state On Green Blink Port2 of M2 is rece...

Страница 16: ...40 transceiver 9 125um single mode fiber 40km SFP LH 70 L transceiver 9 125um single mode fiber 70km SFP LH 120 L transceiver 9 125um single mode fiber 120km SFP GT SFP GT module 1000Base T SFP inter...

Страница 17: ...in the following Figure 1 22 The back panel with extended modules for QSW 8200 28T AC QSW 8200 52T AC Figure 1 23 The back panel with extended modules for QSW 8200 28T AC DC QSW 8200 52T AC DC Figure...

Страница 18: ...QSW 8200 series SFP transceivers description Spec SFP SFP LR transceiver 10GBase LR SFP 1310nm SMF 10km SFP SR transceiver 10GBase SR SFP 850nm 62 5 m MMF 32m 50 m 500MHz km MMF 85m 50 m 2000MHz km M...

Страница 19: ...0V The switch must be well grounded in order to avoid ESD damage and physical injury of people The switch should avoid the sunlight perpendicular incidence Keep the switch away from heat sources and s...

Страница 20: ...ance degradation or even electric leakage degradation of mechanical properties and corrosion of internal components Extreme low relative humidity may cause the insulation spacer to contract making the...

Страница 21: ...ply system grounding extreme fluctuation of the input source and transients or spikes can result in larger error rate or even hardware damage 2 1 1 4 Preventing Electrostatic Discharge Damage Static e...

Страница 22: ...stem Make sure the installation materials and tools are prepared And make sure the installation site is well prepared During the installation users must use the brackets and screws provided in the acc...

Страница 23: ...f electric shock fire electrical short circuit occurs please cut off the electricity supply and alarm rapidly Rescue the injured person in the contingency under inherently safe give the injured person...

Страница 24: ...Hardware Installation 24 www qtech ru 2 3 Installation Guide 2 3 1 Installing the Switch Fig 2 1 QSW 8200 28T AC series installation sketch map on the rack Fig 2 2 QSW 8200 52T AC series installation...

Страница 25: ...ack They can t serve as a bearing Please place a rack shelf under the switch Do not place anything on top of the switch Do not block the blowholes on the switch to ensure the proper operation of the s...

Страница 26: ...Installation QSW 8200 series provide 10Gb slots The procedure for installing the QSW 2SFP module and the SFP 10Gb fiber transceiver is shown below Step 1 Put on an ESD wrist strap or antistatic gloves...

Страница 27: ...able line card Step 2 Insert the other end of the Ethernet cable to the RJ 45 Ethernet port of other device Step 3 Check all status indicators for the corresponding ports a lighted LED indicates that...

Страница 28: ...wer status indicator in the front panel of the switch The corresponding power indicator should light QSW 8200 is self adjustable for the input voltage As soon as the input voltage is in the range prin...

Страница 29: ...and leakage protection and the other end to PoE power socket in the back panel of the switch 2 Connect PD device to the front port of QSW 8200 3 Check whether PD device is powered and the port indicat...

Отзывы: