background image

HARDWARE INSTALLATION AND REFERENCE GUIDE 

 

www.qtech.ru 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QSW-6300 Series Switches 

Hardware Installation and Reference Guide 

 

 

 

 

Содержание QSW-6300 Series

Страница 1: ...HARDWARE INSTALLATION AND REFERENCE GUIDE www qtech ru QSW 6300 Series Switches Hardware Installation and Reference Guide...

Страница 2: ...Technical Specifications 11 1 4 2 Product Appearance 13 1 4 2 1 Front Panel 13 1 4 2 2 Rear Panel 14 1 4 3 Power Supply 14 1 4 4 Heat Dissipation 14 1 4 5 LED 15 1 5 QSW 6300 32F 16 1 5 1 Technical S...

Страница 3: ...tion Procedure 29 3 2 Preparing 29 3 3 Mounting the Switch 29 3 3 1 Mounting the Switch into a Cabinet 30 3 3 2 Mounting the Switch on a Workbench 30 3 4 Installing and Removing the Power Supply Modul...

Страница 4: ...3 Fault 3 The serial port console has no output 40 6 2 4 Fault 4 The serial port console outputs illegible characters 40 6 2 5 Fault 5 The newly inserted service card module fails to be powered on 40...

Страница 5: ...000 BASE X SFP port and one 10 100 1000 BASE T Ethernet port That is only one port of them is available at a particular time SFP port supports both 10G BASE R and 1000 BASE X PoE ports are downward co...

Страница 6: ...GB819 85 8 Grounding Cable 1 Management Software Pre installed 1 1 3 QSW 6300 32T 1 3 1 Technical Specifications Model QSW 6300 32T CPU Dual core with the clock speed of 1 2 GHz BOOTROM 16 MB Flash Me...

Страница 7: ...ating temperature 0 C to 45 C 32 F to 113 F altitude from 0 m to 1800 m 1 12 miles The highest operating temperature decreases by 1 1 8 F as the altitude ranging from 1800 m 1 12 miles to 5000 m 3 11...

Страница 8: ...rts one MGMT port one USB port and one Console port on the front panel two power supply module slots and one expansion slot on the back panel Figure 1 1 Appearance of QSW 6300 32T 1 3 2 1 Front Panel...

Страница 9: ...6300 32T supports 2 power supply modules Dual power input The switch can be powered by one power supply module or two power supply modules When both modules are working the switch is working in power...

Страница 10: ...ture alarm 1 The temperature of inlet outlet vent exceeds the warning threshold 2 The power is insufficient for the system Check the working environment of the switch and power supplies immediately So...

Страница 11: ...nnected Solid green The port is connected at 1 10 Gbps Blinking green The port is receiving or transmitting data at 1 10 Gbps 10 100 1000 BASE T Ethernet port status LED 1 24 Off The port is not conne...

Страница 12: ...equency 50 60 Hz Rated current per input 3 A 150 W power supply SFP Port Supported 10GE SFP Port Downward Compatible SFP Port 10G BASE R Capable 1000 BASE X Capable Power Consumption 70 W Temperature...

Страница 13: ...1 73 in Weight 4 5 kg 9 92 lbs 1 4 2 Product Appearance The QSW 6300 52T Ethernet switch provides 48 10 100 1000Base T Ethernet ports four 10GE SFP ports one MGMT port one USB port and one Console por...

Страница 14: ...ower Supply Module Slot 1 1 4 3 Power Supply The QSW 6300 52T supports two power supply modules Dual power input The switch can be powered by one power supply module or two power supply modules When b...

Страница 15: ...alarm 1 The temperature of inlet outlet vent exceeds the warning threshold 2 The power is insufficient for the system Check the working environment of the switch and power supplies immediately Solid r...

Страница 16: ...nected at 1 10 Gbps Blinking green The port is receiving or transmitting data at 1 10 Gbps 10 100 1000 Base T Ethernet port status LED 1 48 Off The port is not connected Solid green The port is connec...

Страница 17: ...ated current per input 3 A 150 W power supply SFP Port 100 BASE X Capable 1000 BASE X Capable SFP Port 10G BASE R Capable 1000 BASE X Capable Power Consumption 77 W Temperature Operating temperature 0...

Страница 18: ...ovides 24 GE SFP ports port 17 24 do not support the rate of 100Mbps eight 10 100 1000 BASE T combo ports eight 10GE SFP ports one MGMT port one USB port and one Console port on the front panel two po...

Страница 19: ...pply Module Slot 1 1 5 3 Power Supply The QSW 6300 32F supports two power supply modules Dual power input The switch can be powered by one power supply module or two power supply modules When both two...

Страница 20: ...1 The temperature of inlet outlet vent exceeds the warning threshold 2 The power is insufficient for the system Check the working environment of the switch and power supplies immediately Solid red The...

Страница 21: ...The port is not connected Solid green The port is connected at 1 10 Gbps Blinking green The port is receiving or transmitting data at 1 10 Gbps GE SFP port status LED 17F 24F Off The port is not conn...

Страница 22: ...airflow 1 6 1 1 Specifications Power Model QSW M 6300 PWR Device Model QSW 6300 52T QSW 6300 32T QSW 6300 32F Rated Voltage AC input 100 V AC to 240 V AC 50 60 Hz Maximum Voltage AC input 90 V AC to...

Страница 23: ...t to communicate with the power supply module by I2C Power Supply Redundancy Supports dual power supply modules to cooperate in parallel enabling PE with 1 1 redundancy and redundant power supplies wi...

Страница 24: ...he grounding is reliable and whether the ground is wet Learn about the position of the indoor emergency power switch before installation Cut off the power switch in case of accidents Do not maintain t...

Страница 25: ...nt value of each power supply model see the power supply model parameter table in Chapter 1 2 1 4 Electrostatic Discharge Safety To ensure electrostatic discharge safety there are some precautions Pro...

Страница 26: ...the rack 2 2 3 Cleanliness Requirements Dust poses a major threat to the switch The indoor dust takes on a positive or negative static electric charge when falling on the switch causing poor contact o...

Страница 27: ...ing grounding is required only for facilities and is not required for the switch 2 2 4 3 EMC Grounding Grounding required for electromagnetic compatibility includes shielded grounding filter grounding...

Страница 28: ...t but can be controlled by a filter Radiated interference may affect any signal path in the equipment and is difficult to shield Take effective measures for the power system to prevent the interferenc...

Страница 29: ...g Before installation please confirm the following requirements before installation The installation position provides sufficient space for heat dissipation The installation position meets the tempera...

Страница 30: ...ohibited to prevent damages to interfaces due to over voltage or over current caused by lightning 3 3 1 Mounting the Switch into a Cabinet The QSW 6300 series switches follow the EIA standard dimensio...

Страница 31: ...l it clicks into place Figure 3 5 Installing a Power Supply Module Note Insert the power supply module straightly and slowly Verify that the power supply module is in the correct orientation Insert th...

Страница 32: ...d in an easily operable position near the switch During the device installation always make the ground cable connected first and disconnected last The cross sectional area of the protection ground cab...

Страница 33: ...along the chassis downward in a straight line wherever possible 3 8 Verifying Installation Note Before verifying the installation cut off the power supply to avoid any personal injury or damage to th...

Страница 34: ...adopt console cable connecting Plug the DB 9 head of the console cable into the network port of the PC Plug the RJ45 connector of the console cable into the console port of the switch 4 1 3 Setting Te...

Страница 35: ...new connection and click OK A window appears as shown in Figure 4 3 In the Connect Using field select the serial port you want to use Figure 4 3 4 After selecting the serial port click OK The Serial P...

Страница 36: ...k whether the switch is properly grounded Check whether the power cord is properly connected Check whether the power supply voltage meets the requirement Check whether the network cable is properly co...

Страница 37: ...o support the whole system insert RPS modules When the PWR1 PWR2 indicator of the device is red check whether the power cord is in place and operational if yes it indicates that the power supply is fa...

Страница 38: ...without external power supply To replace lithium batteries please contact technical support personnel of QTECH Networks The technical support personnel will select lithium batteries of the same specif...

Страница 39: ...m login password of the switch is forgotten or lost and so it is not possible to configure the data Troubleshooting Please contact QTECH Customer Service Department for technical support 6 2 2 Fault 2...

Страница 40: ...blem is related to the settings of the serial port Check if the settings of such parameters as the baud rate match those in QSW 6300 Series Switch RGOS Configuration Guide 6 2 5 Fault 5 The newly inse...

Страница 41: ...tion and Reference Guide Troubleshooting 41 Check whether the rates of the two sides match and whether the optical fiber type meets requirements In addition for ports supporting different rate check w...

Страница 42: ...feet The 1000BASE T port uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Schemati...

Страница 43: ...m for optical fiber connection 7 2 Appendix C Lightning Protection 7 2 1 Installing AC Power Arrester Lightning Protection Power Strip The AC power port must be connected to an external lightning prot...

Страница 44: ...protection function is implemented only if the RUN indicator is green and the ALARM indicator is OFF If the ALARM indicator on the power arrester is red check whether it is caused by poor grounding c...

Страница 45: ...Figure C 2 Ethernet port Arrester Installation Note The Ethernet port arrester is only for the 10 M 100 M copper Ethernet ports with an RJ 45 connector The Ethernet port arrester is not delivered with...

Страница 46: ...The bend radius of the fixed high speed cable that is often bent or plugged should be over 10 times greater than its diameter 7 3 2 Requirement for the Minimum Fiber Bend Radius The diameter of a fib...

Страница 47: ...p cables with cable ties cut off the remaining part The cut should be smooth and trim without sharp corners as shown in Figure D 2 Figure D 2 Binding Cables 2 When cables need to be bent please bundle...

Страница 48: ...Fastening 1 Flat washer 2 Nut 3 Spring washer 4 Flat washer Hard power cords should be fastened in the terminal connection area to prevent stress on terminal connection and cable Do not use self tapp...

Страница 49: ...e equipment room should be firm enough to withstand severe weather conditions such as windstorm and heavy rain The equipment room should be away from the dusty road or quarry If the dust is unavoidabl...

Страница 50: ...hes Hardware Installation and Reference Guide 50 8 8 1 qtech ru 8 2 QTECH QTECH sc qtech ru 8 3 helpdesk qtech ru 7 495 797 33 11 0 8 4 21 09 2022 https files qtech ru upload switchers QSW 6300 QSW 63...

Отзывы: