Руководство пользователя
8. Product Technical Specifications
230
www.qtech.ru
External port&PCIE
Front port: VGA, 2 USB3.0
Rear: VGA, 2 USB3.0, 1 management
network port, 2 RJ45 network ports
PCIE expansion board: up to 10 PCIE
expansion slots OCP slot: 1 OCP 3.0 (X8)
System fan
Standard 4 8038 N+1 hot-swappable
redundant fans,
optional 4 8056 N+1 hot-swappable
redundant fans
network
Onboard 2 1GbE or 10GbE (RJ45)
Security
TPM/TCM (optional)
Chassis opening intrusion detection
Lock the upper cover of the chassis
The onboard iBMC management module
supports management features such as
IPMI, SOL, KVM Over IP, and virtual
media
management
Microsoft Windows Server, Red Hat
Enterprise Linux, SUSE Linux Enterprise
Server, CentOS, Ubuntu
Citrix Xen Server, Vmware ESXi, Linux
KVM, Windows Hyper-V
Operating
Standard operating temperature: 10ºC-
40ºC (without direct sunlight) Extended
operating temperature: 5ºC-40ºC (limited
configuration meets)
Transportatio
n storage temperature: 10ºC-
40ºC Working humidity: 30%-80% (non-
condensing) Storage humidity: 5%-95%
(non-condensing)
Table 1- 29
Содержание QSRV-26 Series
Страница 1: ...www qtech ru QTECH QSRV 26xxxx platform 2U manual server barebones...
Страница 33: ...2 Product Introduction 33 www qtech ru Figure 2 9...
Страница 51: ...3 Installing System Components 51 www qtech ru Figure 3 14 Figure 3 15...
Страница 57: ...3 Installing System Components 57 www qtech ru Figure 3 25 Figure 3 26...
Страница 60: ...3 Installing System Components 60 www qtech ru Figure 3 30 Figure 3 31...
Страница 64: ...3 Installing System Components 64 www qtech ru Figure 3 37...
Страница 67: ...4 System cabinet Installation 67 www qtech ru Figure 4 2...
Страница 70: ...4 System cabinet Installation 70 www qtech ru Figure 4 5...
Страница 88: ...5 BIOS parameter setting description 88 www qtech ru 5 2 13 Network Stack Configuration Figure 5 13...
Страница 127: ...5 BIOS parameter setting description 127 www qtech ru 5 2 40 BMC network configuration menu Figure 5 41 Figure 5 42...
Страница 135: ...5 BIOS parameter setting description 135 www qtech ru User Operator Administrator...
Страница 148: ...6 RAID Setting Instructions 148 www qtech ru Figure 6 12...
Страница 184: ...6 RAID Setting Instructions 184 www qtech ru Figure 6 76...
Страница 199: ...6 RAID Setting Instructions 199 www qtech ru Figure 6 105...
Страница 204: ...6 RAID Setting Instructions 204 www qtech ru Figure 6 57...
Страница 208: ...6 RAID Setting Instructions 208 www qtech ru Figure 6 120...
Страница 225: ...7 IPMI Rapid Deployment 225 www qtech ru Figure 7 13 KVM interface composition...