10
TSC-50-G3 In-Wall Mounting
The TSC-50-G3 is designed to be installed into single gang electrical boxes that are common in North America as well as circular
electrical boxes available in Europe. While a variety of single gang electrical boxes are supported, a rectangular box with a minimum
cavity of 18 cubic inches is recommended. For installations using a European circular back box, a minimum box depth of 60 mm is
recommended.
IMPORTANT!:
Verify suitability of your selected electrical box, including LAN cable routing, prior to installation.
IMPORTANT!:
Orientation of electrical box installation must match orientation of TSC-50-G3 wall mount bracket.
1. Prepare the TSC-50-G3 wall mount bracket for installation by pushing the sliding arm
forward so that the spring mechanism locks in place. See — Figure 1.
2. Prepare the TSC-50-G3 for installation by partially installing two M2.5 screws into the sides
of the Touch Screen Controller. Install the screws approximately 1/2 turn in order to leave
sufficient space between the head of each screw and the side of the Touch Screen Controller
to accommodate the wall mount bracket arm. See — Figure 2.
3. Ensure that the LAN cable includes sufficient length to provide proper stress relief.
4. Route the LAN cable through the cable opening in the wall mount bracket. See — Figure 3.
5. Align the wall mount bracket to the electrical box and install using the supplied #6-32 screws.
When installing in portrait orientation, the word “Portrait” MUST be displayed in the upper-
left corner of the wall mount bracket. When installing in landscape orientation the word
“Landscape” MUST be displayed in the upper-left corner of the wall mount bracket.
See — Figure 3
NOTE:
Screws are not supplied for circular back boxes or alternate
mounting brackets.
No
Yes
— Figure 1 —
Arm
Spring
— Figure 2 —