17-

 Select 

Device

Add Device

, from the menu. A new window will open prompting you to name the device. Name it logically, such 

as RAVE 1, or similar. Select the Device Type and select RAVE 520uz. At the Password prompt, enter “qsc” (lower case, no quotation 
marks). This is the device password, separate from the software password. The default, in both cases, is “qsc”, but you are free to 
change either or both. Enter the IP address of the RAVE and click 

OK

.

18-

 The RAVE will now appear in the inventory root (left side of screen, first with a red “x”, then a yellow exclamation point, then a nor-

mal icon). If the RAVE does not eventually show in the inventory root, check that a crossover cable is used (only for RAVE connected 
directly to PC), check the cable connections, verify IP addresses are set correctly, verify Subnet masks are set correctly, and verify AC 
power is properly applied to the RAVE.

19- 

Click on the “+” sign of the RAVE 520uz in the inventory root, then the “+” sign of the Flashed Configs. Click on the config with the 

loudspeaker icon. A view of applicable device tabs will open. Click the DSP tab and the current DSP configuration of the RAVE will be 
displayed. 

20- 

Right click on the 

Design Editor

 icon in the lower left of your display; select “New”. A new window opens; select RAVE 520uz for 

the device type.

21-

 Click on 

Help

 to access the software’s Help system. All software operation is covered in the on-line help file.

Operation of the RAVE 520uz is accomplished with the included QSControl.net software. No software 
operation is covered in this hardware manual. After installing your software, open the Help file and 
follow its recommendations. The software Help file includes the most recent information available 
for your RAVE 520uz.

Содержание RAVE 520uz

Страница 1: ...TD 000201 00 rev A TD 000201 00 RAVE 520uz 8 input CobraNet Enabled Signal Processor Hardware Manual...

Страница 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Страница 3: ...Thus the sound system can be operated via several computers roaming wireless laptops tablets etc all at the same time from anywhere a connection to the QSControl net network is available The QSControl...

Страница 4: ...lities to both RAVE and QSControl net Our latest code releases and access to up to date information on RAVE and QSCon trol net are available at www qscontrol net We invite you to visit us there We ve...

Страница 5: ...pologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Network Systems Design As with any communications system the rel...

Страница 6: ...is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not r...

Страница 7: ...ion while passing audio between them all without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary connection you...

Страница 8: ...to point Though the example shows only one RAVE 520uz and one audio destination product such as the BASIS 922az as many devices may be connected as there are available switch ports All RAVE BASIS unit...

Страница 9: ...t audio traffic This config uration essentially provides a dedicated network for RAVE BASIS management including the system controller and a second dedicated network for CobraNet audio As with the pre...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Страница 12: ...ystem is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system st...

Страница 13: ...ily mute allow ing the RAVE 520uz to synchronize with its internal clock If CobraNet network connection is re established the audio will mute again while the RAVE 520uz synchronizes with CobraNet Conf...

Страница 14: ...nal block connectors into the input recep tacles Connection pin out is printed on the rear label for reference Refer to the illustrations for balanced and unbalanced connections Use balanced audio inp...

Страница 15: ...oning AC out let it will power up and briefly display a welcome screen on the LCD display POWER Indicator This blue indicator illuminates when the RAVE 520uz is plugged into a properly functioning AC...

Страница 16: ...cept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices entering by pushing in on the control The accessible menus and sub men...

Страница 17: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Страница 18: ...cify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Selec...

Страница 19: ...verify IP addresses are set correctly verify Subnet masks are set correctly and verify AC power is properly applied to the RAVE 19 Click on the sign of the RAVE 520uz in the inventory root then the s...

Страница 20: ...currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the RAVE will process the data accordingly All DACs will process 24 bit audio though th...

Страница 21: ...cate with the RAVE 520uz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port inp...

Страница 22: ...click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the RAVE 520uz you want to communicate with in the text box and cli...

Страница 24: ...trically balanced Grounding All shield terminals connected to chassis Pinout 1 2 3 CHASSIS GND Input Impedance nom Balanced 6 81k ohms Unbalanced 13 6k ohms Common Mode Rejection 20Hz 20KHz min 54dB 2...

Страница 25: ...nd referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation Use 10K for full range Voltage Tolerance 48V Current Output 0 5mA with 1...

Страница 26: ...26 Dimensions...

Страница 27: ......

Страница 28: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: