background image

2

TD-000520-00-A

EXPLANATION OF TERMS AND SYMBOLS

The term “

WARNING!

” indicates instructions regarding personal safety. If the instructions are not followed the result may 

be bodily injury or death.

The term “

CAUTION!

” indicates instructions regarding possible damage to physical equipment. If these instructions are 

not followed, it may result in damage to the equipment that may not be covered under the warranty.

The term “

IMPORTANT!

” indicates instructions or information that are vital to the successful completion of 

the procedure.

The term "

NOTE

" is used to indicate additional useful information.

The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-
insulated "dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a 
risk of electric shock to humans. 

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important 

safety, and operating and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

WARNING!!:

 

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. 

• 

Elevated Operating Ambient

 - If installed in a closed or multi-unit rack assembly, the ambient operating 

temperature of the rack environment may be greater than room ambient. Consideration should be given to 
ensure that the maximum operating temperature range (0°C to 50°C (32°F to 122°F ) is not exceeded.

• 

Reduced Air Flow

 – Installation of the equipment in a rack should be such that the amount of air flow 

required for safe operation of the equipment is not compromised.

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Do not submerge the apparatus in water or liquids. 
7.  Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. 
8.  Clean only with a dry cloth.
9.  Install in accordance with the manufacturer's instructions.
10.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) 

that produce heat.

11.  Do not unplug the unit by pulling on the cord, use the plug.
12.  Only use attachments/accessories specified by the manufacturer.
13.  Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any 

way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, 

the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15.  Adhere to all applicable, local codes.
16.  Consult a licensed, professional engineer when doubt or questions arise regarding a physical equipment installation.

Содержание Q-SYS

Страница 1: ...Hardware User Guide I O 8 Flex Channel Expander TD 000520 00 A TD 000520 00...

Страница 2: ...ient Consideration should be given to ensure that the maximum operating temperature range 0 C to 50 C 32 F to 122 F is not exceeded Reduced Air Flow Installation of the equipment in a rack should be s...

Страница 3: ...ause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter...

Страница 4: ...Assemblies X O O O O O Chassis Assemblies X O O O O O SJ T 11364 O GB T 26572 X GB T 26572 This table is prepared following the requirement of SJ T 11364 O Indicates that the concentration of the subs...

Страница 5: ...ck Ear 2x Joining Plate 1x Rack Ear Cover Label 6x Phillips Pan Head M4 x 7 mm 6x Phillips Flathead M3 x 6 mm 4x Foam Spacer 8x Flex Channels blue 1 External Power green 1 RS232 Tx Rx green 2x GPIO bl...

Страница 6: ...of heat keep the space directly above and to the rear of the I O 8 Flex free of obstacles 2 1 Select the I O 8 Flex Installation Configuration Choose one of the following configuration options A One...

Страница 7: ...6 5 1 6 6 4 3 3 4 5 1 1 6 2 4 3 3 4 5 1 6 1 2 Front Panel Bottom Side Amp 2 Bottom Side Amp 1 Front Panel Rear Panel Bottom Side Amp 2 Bottom Side Amp 1 Rear Panel A One I O 8 Flex 19 inch Rack Left o...

Страница 8: ...Rear Facing Out 1 1 2 2 3 6 1 2 3 3 2 1 2 3 Top Side Front Panel Top Side Rear Panel D Under Table or on Wall 1 1 2 2 3 6 4 4 Not supplied use appropriate screws for mounting surface 5 Mounting Surfac...

Страница 9: ...mounting options A through E you can mount any of the I O 8 Flex configurations The example at the lower right can be flipped to accommodate a single I O 8 Flex on the left side 1 Equipment Rack not...

Страница 10: ...ion uses the farthest left pins not numbered for both GPIO INPUTS and GPIO OUTPUTS 3 GPIO OUTPUT 8 outputs open collector 24V 0 2A maximum with pull up to 3 3V pins 1 8 equal pins 1 8 in the Q SYS Des...

Страница 11: ...that the plugs do not straddle two channels Balanced Unbalanced Communication and Power Connectors Make the following connections as required 1 3 pin Euro connector for RS232 TX and RX 2 USB Type B fo...

Страница 12: ...mically Paired and Not Required has no hardware assigned to it System Status Firmware A three section number identifying the major release minor release and maintenance release For example 6 0 0 Temp...

Страница 13: ...put signal over driving the associated channel output Signal Displays a solid circle when there is a signal present on the associated channel 48V Displays a sold circle when phantom power is active on...

Страница 14: ...14 TD 000520 00 A Dimensions 220mm 8 66 in 240mm 9 43 in 44mm 1 75 in...

Страница 15: ...0 dB typical 90 dB maximum 12 dBu Input Sensitivity 120 dB typical 90 dB maximum Input Dynamic Range 24 dBu Input Sensitivity 107 dB 12 dBu Input Sensitivity 107 dB Mic Preamp EIN 125 dBu Phantom Powe...

Страница 16: ...ollector 24VDC at 200mA max internal 1 0K pullup to 3 3V GPIO 12VDC Power Pins 12VDC out at 100mA max Miscellaneous PoE Power Input IEEE 802 3at class 4 compliant PD requires full power from an IEEE 8...

Страница 17: ...pport Application Engineering and Technical Services Monday Friday 7 AM to 5 PM PST Excludes Holidays Tel 1 800 772 2834 U S only Tel 1 714 957 7150 Q SYS 24 7 Emergency Support Tel 1 888 252 4836 U S...

Отзывы: