EXPLANATION OF TERMS AND SYMBOLS

The term “

WARNING!

” indicates instructions regarding personal safety. If the instructions are not followed the result may be 

bodily injury or death.

The term “

CAUTION!

” indicates instructions regarding possible damage to physical equipment. If these instructions are not 

followed, it may result in damage to the equipment that may not be covered under the warranty.

The term “

IMPORTANT!

” indicates instructions or information that are vital to the successful completion of the procedure.

The term "

NOTE

" is used to indicate additional useful information.

The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-
insulated "dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a 
risk of electric shock to humans. 

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important 

safety, and operating and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

 WRRIRNG!:

 

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.  

Elevated Operating Wmbient

 - If installed in a closed or multi-unit rack assembly, the ambient operating temperature 

of the rack environment may be greater than room ambient. Consideration should be given to ensure that the maximum 
operating temperature range (0°C to 50°C (32°F to 122°F ) is not exceeded. 

Reduced Wir Flow

 – Installation of the 

equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not 
compromised.

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Do not submerge the apparatus in water or liquids. 
7.  Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. 
8.  Clean only with a dry cloth.
9.  Do not block any ventilation opening. Install in accordance with the manufacturer's instructions.
10.  Keep all ventilation openings free of dust or other matter.
11.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) 

that produce heat.

12.  To reduce the risk of electrical shock, the power cord shall be connected to a mains socket outlet with a protective 

earthing connection.

13.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one 

wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the 

third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

14.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point 

where they exit from the apparatus.

15.  Do not unplug the unit by pulling on the cord, use the plug.
16.  Only use attachments/accessories specified by the manufacturer.
17.  Unplug this apparatus during lightning storms or when unused for long periods of time.
18.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any 

way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, 

the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Содержание Q-SYS Cinema Core 510c

Страница 1: ...Hardware User Guide CORE 510i Integrated Core Processor CORE 510c Cinema Core Processor TD 000521 00 A TD 000521 00...

Страница 2: ...se instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Do not submerge the apparatus in water or liquids 7 Do not use any aero...

Страница 3: ...HORT CIRCUIT THE BATTERY DO NOT ATTEMPT TO RECHARGE THE NON RECHARGEABLE LITHIUM BATTERY THERE IS A RISK OF EXPLOSION IF THE BATTERY IS REPLACED BY AN INCORRECT TYPE FCC Statement This equipment has b...

Страница 4: ...DE PCB Assemblies X O O O O O Chassis Assemblies X O O O O O SJ T 11364 O GB T 26572 X GB T 26572 This table is prepared following the requirement of SJ T 11364 O Indicates that the concentration of t...

Страница 5: ...the rack rails Install all four mounting screws and washers and tighten securely This Q SYS product comes with rear rack support ears Ensure that these rear mounting points are securely fastened to re...

Страница 6: ...B Ports USB Type A Host connectors 2 Rear Panel Figure 2 8 5 3 7 6 4 2 1 1 Eight Audio I O Card Bays Accept Q SYS Type 2 Audio I O Cards supports up to 128x128 local audio channels 2 GPIO A and GPIO B...

Страница 7: ...release and maintenance release For example 6 0 0 Temp The current chassis temperature of the Core Fan Speed This number varies with the temperature LAN A Refer to Figure 5 You can edit this informati...

Страница 8: ...Mic Line In Standard card status screen shows the Mute state Signal presence Clip indication and 48V state of each of the 4 input channels Mute Displays a muted loudspeaker when the channel is muted S...

Страница 9: ...ES16 Refer to Figure 11 16 Channel AES3 In card screen shown The AES3 16 channel card status screen shows the Signal presence and Lock state for all 16 input channels Signal Displays a solid circle wh...

Страница 10: ...e Dante device that will be seen by other connected Dante devices Connections AC Power Cord Insert the molded IEC recepticale connector of the AC power cord into the IEC AC power inlet on the back of...

Страница 11: ...fiers Note that multi channel amps can spread accross multiple DataPort IO cards as long as they are in the same Core or IO Frame Audio Network Cards and 16 Channel AES3 Input Card CIAES16 Audio Netwo...

Страница 12: ...ut High 11 V min 13 V max High Current Output sink 280 mA High Current Output source Not supported High Current Output sink or source 280 mA NOTE The maximum current sourced by one GPIO connector incl...

Страница 13: ...peed and direction Output issimilar to an H Bridge topology High Current Pin High Current Pin M1 12 V Motor 12 V Pin Normal or High Current Pin Ground R1 R2 R3 R4 T1 T2 D1 LED D2 LED Normal or High Cu...

Страница 14: ...tion purposes The screws are only used on cards in positions G and H All other cards must use the standoffs b For cards in positions A through F remove the cards in positions G and or H step 6 a then...

Страница 15: ...n of this type of QoS on a given network switch can vary depending on the manufacturer and switch model For more details about network and switch setup refer to the Help File in Q SYS Designer NOTE Fo...

Страница 16: ...16 TD 000521 00 A Dimensions Figure 25 19 in 481mm 15 0 in 381mm 16 25 in 412 8mm 19 in 481mm 3 5 in 89mm...

Страница 17: ...Line Input card 4 channels CAES4 AES3 Digital I O card 4 x 4 channels CIAES16 AES3 Digital Input card 16 channels CCN32 CobraNet Network Bridge card up to 32 x 32 channels CAN32 AVB Network Bridge car...

Страница 18: ...ry FCC 47 CFR Part 15 Class A IC ICES 003 CE EN55032 EN55035 EU RoHS directive 2011 65 EU WEEE directive 2012 19 EU China RoHS directive GB T26572 EAC RTL UL C UL Product Dimensions 3 5 x 19 x 15 89mm...

Страница 19: ...ort Application Engineering and Technical Services Monday Friday 7 AM to 5 PM PST Excludes Holidays Tel 800 772 2834 U S only Tel 1 714 957 7150 Q SYS 24 7 Emergency Support Tel 1 888 252 4836 U S Can...

Отзывы: