SPECIFICATIONS

PL325

PL340

PL380

Stereo Mode (both channels driven)
 

 / EIA 1 kHz / 1% THD

 

 / EIA 1 kHz / 1% THD

 

 / EIA 1 kHz / 1% THD

500 W
850 W
1250 W

800 W
1250 W
2000 W

1500 W
2500 W
4000 W*

Bridge Mono Mode
 

 / EIA 1 kHz / 1% THD 

 

 / EIA 1 kHz / 1% THD

1700 W 
2500 W

2600 W 
4000 W

5000 W 
8000 W*

Typical Distortion  
(20 Hz - 3 kHz, 3dB below clip, or 20 Hz -  
5 kHz, 10 dB below clip, or 20 Hz - 20 kHz, 
20 dB below clip)
 

 

 

 
 
 

0.002 - 0.01%
0.005 - 0.01%
0.02%

 
 
 

0.002 - 0.01%
0.005 - 0.01%
0.02%

 
 
 

0.01 - 0.03%
0.03 - 0.06%
0.1%

Maximum Distortion  
(20 Hz - 20 kHz, 1 dB below rated power)
 

4 - 8 

 

0.05%

 

0.05%

 

0.2%

Frequency Response (8 

Ω)

20 Hz - 20 kHz, +/-0.2 dB

20 Hz - 20 kHz, +/-0.2 dB

20 Hz - 20 kHz, +/-0.2 dB

Noise (20 Hz - 20 kHz, 32 dB Gain)

-106 dB

-105 dB

-104 dB

Dynamic Headroom (4 

Ω)

2 dB

2 dB

2 dB

Damping Factor (8 

Ω)

500

500

200

Output Circuitry

Class H (2-tier)

Class H (2-tier)

Class D

Input Sensitivity
 

(26 dB Setting)

 

(32 dB Setting)

3.28 V
1.60 V

3.92 V
1.96 V

5.27 V
2.67 V

Input Gain (1.2 V Setting)

34.5 dB

36.4 dB

39.1 dB

Input Impedance (

Ω)

>10k, balanced or unbalanced

>10k, balanced or unbalanced

>10k, balanced or unbalanced

Maximum Input Level
 

(1.2 V Setting)

 

(32 dB Setting)

 

(26 dB Setting)

11 V (+23 dB)
14.6 V (+25.5 dB)
25 V (+30 dB)

11 V (+23 dB)
18 V (+27.4 dB)
25 V (+30 dB)

10 V (+22 dB)
22 V (+29 dB)
25 V (+30 dB)

Controls and LEDs - Front Panel

Common: AC Power Switch, Power (Blue), Br Mono (Yellow), Par (Orange) 
Each Channel: Signal -35 dB, -20 dB (Green), -10 dB (Orange), Clip/Prot (Red), Gain Control, 21 detents, 1 dB steps

Controls and LEDs - Rear Panel

Common: Input Mode: Parallel (Orange), Stereo (Green), Br Mono (Yellow) Sensitivity:  26 dB (Orange),  32 dB (Green), 1.2 V (Yellow)
Each Channel: LF Filter: Off, 30 Hz (Yellow), 50 Hz (Orange) Clip Limit: Off, On (Yellow)

Input Connectors

Common: HD-15 DataPort (inputs wired in parallel with XLR)
Each Channel: Male XLR, Female XLR, 3-pin terminal block connector

Output Connectors

Each Channel: 5-way Binding Posts, Neutrik Speakon

®

, (Both Ch 1 and Ch 2 amp outlets available on Ch1 Speakon

®

)

Amplifier and Load Protection

Short circuit, open circuit, thermal, RF protection. On/off muting, DC fault shutdown, active inrush limiting

AC Power** / Cordset 
 

120 V 50/60 Hz

 

230 V 50 Hz

8.5 A / NEMA-15
7.5 A / Euro 16 A

12 A / NEMA-15
7 A / Euro 16 A

18 A / 30 A Twist-Loc
11 A / Euro 16 A

Dimensions (HWD)

Height: 3.5" (8.9 cm) 2 RU / Width: 19" (48.3 cm) / Depth: 15.63" (39.7 cm) from front mounting rails

Weight - Net / Shipping

22 lb (10 kg) / 31.5 lb (14.3 kg)

22 lb (10 kg) / 31.5 lb (14.3 kg)

24 lb (11 kg) / 33.5 lb (15.2 kg)

U. S. Patent no. 5767744 and patents pending
* Burst mode testing required due to AC service current limitations
** Representative of current draw with typical music program material with occasional clipping
All specifications are subject to change without notice.

 

 

 

 

 

 

Содержание PowerLight PL325

Страница 1: ...PowerLight 3 Series 2500 to 8000 watt lightweight 2RU amplifiers for use in the most demanding concert and live sound reinforcement applications WideLine 8 shown...

Страница 2: ...or retakes Night after night venue upon venue across the globe QSC professional audio systems do exactly what Pat Quilter and his team of engineers designed them to do deliver Ultimate Audio Performan...

Страница 3: ...drum monitors or out at FOH aligning the subs with the mains you know that head room is not measured by instantaneous peak power ratings It s the ability of the entire amplifier from power supply to...

Страница 4: ...gh power Class D designs The PL380 won t lose efficiency when driving reactive loads That s important in the real world of concert sound Unrivalled Audio Performance From the ultra fast modulator its...

Страница 5: ...cator layout it simplifies building and or reconfig uring your racks and keeps your wiring neat and clean You may want to use other amplifiers alongside the PowerLight 3 Series That s why all three of...

Страница 6: ...well both Neutrik Speakon and Touch Proof binding posts are included on all three amplifiers The channel 1 Speakon carries both output channels for direct connection to bi ampli fied loudspeakers Choo...

Страница 7: ...es from exceeding normal operating current loads High Frequency Protection Most switchmode amplifiers mute when attempting to reach full power at 20 kHz especially into low impedance loads The PL380 a...

Страница 8: ...ed 10k balanced or unbalanced 10k balanced or unbalanced Maximum Input Level 1 2 V Setting 32 dB Setting 26 dB Setting 11 V 23 dB 14 6 V 25 5 dB 25 V 30 dB 11 V 23 dB 18 V 27 4 dB 25 V 30 dB 10 V 22 d...

Отзывы: